interzone 954 antifungus report

10
International Paint Sdn Bhd (151925-T) Lot 1 & 2, Jalan Gangsa 81700 Pasir Gudang Johor, Malaysia T +607 254 1117 F +607 251 4775 www.akzonobel.com/international Registered office Lot 1 & 2, Jalan Gangsa, 81700 Pasir Gudang, Johor, Malaysia. Registered in Malaysia No. 151925-T TESTING REPORT ON INTERZONE 4954

Upload: steffy182

Post on 19-Feb-2015

126 views

Category:

Documents


13 download

TRANSCRIPT

Page 1: Interzone 954 Antifungus Report

International Paint Sdn Bhd (151925-T)

Lot 1 & 2, Jalan Gangsa 81700 Pasir Gudang Johor, Malaysia

T +607 254 1117 F +607 251 4775 www.akzonobel.com/international

Registered office Lot 1 & 2, Jalan Gangsa, 81700 Pasir Gudang, Johor, Malaysia. Registered in Malaysia No. 151925-T

TESTING REPORT

ON

INTERZONE 4954

Page 2: Interzone 954 Antifungus Report

Introduction

Due to market requirement of coating with antifungus properties used on the

sweating pipes in the PC market, IPM decided to come out a solution to fulfil this

requirement.

Referring to the success trail from IP Brazil by using Interthane 990 with 1% KT2037

antifungus biocide, IPM do the same to add in antifungus biocides to Interzone 954

for trial. Result is satisfactory both from us and customers.

To differentiate this product after modification of the formulation, a new banner

name has been given to this new product:

INTERZONE 4954

Beside the test report from IP Brazil, IPM provides this technical report which consist

of two parts as stated belows:

PART A : Laboratory trial QC performance

PART B : Site testing on antifungus performance

Page 3: Interzone 954 Antifungus Report

TEST REPORT FOR INTERZONE 4954

PART A : LAB TRIAL QC PERFORMANCE

Date : 5th June 2009

Test Date : 3rd

June 2009

Product

:

Interzone 4954 – Antifungal paint

Method:

• Run EAZ000 formulation and add KT2037 (1.00%).

• Check QC Tests & storage stability.

Result:

QC Tests

Specifications Results

1) Solution Bit Free

Yes Yes

2) Grind (SMT28A)

60 mics 60 mics

3) Specific Gravity (SMT25A)

1.742-1.796 1.751

4) Viscosity (SMT26F)

3.2-4.2 poise 6.4 poise

5) Hold Up (SMT33)

>=1000 mics 1000 mics

6) Touch Dry (SMT46A)

(400 mics cube applicator)

<=3 hours 4.5 hours

7) Hard Dry (SMT46A) <=18 hours 18 hours

8) Storage Stability 2 months storage result shows this paint still within

specification except viscosity still maintain 6.3-6.4

poises and touch dry at 4.5 hours. Hard dry still

maintain as 18 hours.

Page 4: Interzone 954 Antifungus Report

Conclusion:

All the QC Test properties are within specification except for viscosity and drying time. The

lab sample size at 250ml may contribute to higher viscosity due to insufficient stirring power

compare to production. Longer touch dry result may not also represent production result as

we can see that hard dry still within specification.

Thus, further monitoring need to be conduct in production scale for final determination of

result.

Page 5: Interzone 954 Antifungus Report

PART B: SITE TESTING ON ANTIFUNGUS PERFORMANCE

1) BASF PETRONAS CHEMICAL SDN BHD

Project : Resistance of Interzone 4954 antifungus performance on wet surface

Source : IPM technical sales representative – Mohd Khairil Syahrin bin Zakaria

Pictorial Progress on Antifungus Performance:

No. Description Picture

1) Date : 17/7/09

Before surface preparation

Date : 17/7/09

After washing down

Page 6: Interzone 954 Antifungus Report

Date : 17/7/09

After sand down

2) Date : 17/7/09

After apply Interzone 4954

3) Date : 5/9/09

After 50 days

Page 7: Interzone 954 Antifungus Report

4) Date : 28/1/09

After 195 days

We can see a lot of fungus

attach on pipes which didn’t coated

with Interzone 4954

5) Date : 30/3/09

After 256 days

Page 8: Interzone 954 Antifungus Report

2) GPP 1/ KOMPLEKS A / PGB

Project: Resistance of Interzone 4954 antifungus performance on wet surface

Source : IPM technical sales representative – Mohd Khairil Syahrin bin Zakaria

Pictorial Progress on Antifungus Performance:

No. Description Picture

1) Date : 19/1/09

Overview of sweating line before

apply Interzone 4954

2) Date : 19/1/09

Close up view of area to be coated

after surface preparation to

minimum standard St3

3) Date : 19/1/09

Sweating line after paint application

of Interzone 4954.

Page 9: Interzone 954 Antifungus Report

4) Date : 29/4/09

Overview of sweating line that had

been coated with Interzone 4954

after 3 months

5) Date : 29/4/09

Close up view condition of sweating

line after 3 months

6) Date : 29/4/09

Close up view condition of another

part of sweating line after 3 months

Page 10: Interzone 954 Antifungus Report

7) Date : 26/8/09

Overview of sweating line that had

been coated with Interzone 4954

after 7 months.

Conclusion:

Interzone 4954 showed excellent antifungus resistance properties at site testing.

Prepared By: Edmund Tan (IPM Technical Manager)