akta dan peraturan elektrik

8
NAMA KURSUS SIJIL TEKNOLOGI ELEKTRIK TAJUK MODUL AKTA BEKALAN, PERATURAN-PERATURAN ELEKTRIK DAN PIAWAIAN MS IEC 60364 TAJUK SUB MODUL Electrical Installation of Building-Paiwaian MS IEC 60364 Guide To MS IEC 60364 OBJEKTIF PRESTASI / Performance Objective (PO) Menerangkan mengenai Peraturan Electrical Installation of Building berpandukan Paiwaian MS IEC 60364 supaya kerja-kerja pepasangan elektrik mengikut standard yang ditetapkan. KOD RUJUKAN MUKA: 1 DRP: 6 NAMA NO. K/P TAJUK : Perbezaan MS IEC 60364 Dengan I.E.E TUJUAN : Helaian tugasan ini adalah bertujuan untuk memantapkan kefahaman dan meningkatkan kemahiran pelatih tentang perbezaan peraturan MS IEC 60364 dan Peraturan I.E.E. ARAHAN : Pelatih dikehendaki menjawab semua soalan didalam helaian tugasan ini. HELAIAN TUGASAN HELAIAN TUGASAN (Assignment Sheet) (Assignment Sheet)

Upload: hanim-husaif

Post on 28-Apr-2015

649 views

Category:

Documents


8 download

DESCRIPTION

SOALAN TEORI 4

TRANSCRIPT

Page 1: Akta dan Peraturan Elektrik

NAMA KURSUS SIJIL TEKNOLOGI ELEKTRIK

TAJUK MODULAKTA BEKALAN, PERATURAN-PERATURAN ELEKTRIK DAN PIAWAIAN MS IEC 60364

TAJUK SUB MODULElectrical Installation of Building-Paiwaian MS IEC 60364Guide To MS IEC 60364

OBJEKTIF PRESTASI /Performance Objective

(PO)

Menerangkan mengenai Peraturan Electrical Installation of Building berpandukan Paiwaian MS IEC 60364 supaya kerja-kerja pepasangan elektrik mengikut standard yang ditetapkan.

KOD RUJUKAN

MUKA: 1 DRP: 6

NAMA NO. K/P

TAJUK : Perbezaan MS IEC 60364 Dengan I.E.E

TUJUAN :

Helaian tugasan ini adalah bertujuan untuk memantapkan kefahaman dan meningkatkan kemahiran pelatih tentang perbezaan peraturan MS IEC 60364 dan Peraturan I.E.E.

ARAHAN :

Pelatih dikehendaki menjawab semua soalan didalam helaian tugasan ini.

HELAIAN TUGASANHELAIAN TUGASAN(Assignment Sheet)(Assignment Sheet)

Page 2: Akta dan Peraturan Elektrik

KOD RUJUKAN MUKA: 2 DRP: 6

Soalan 1

Berikan maksud MS IEC 60364 dan I.E.E ?

i. ......................................................................................

ii. ......................................................................................

( 2 MARKAH)

Soalan 2

Isikan tempat kosong di bawah berpandukan perbezaan MS IEC 60364 dan I.E.E ?

No

Subject MSIEC60364 BS7671 (IEE 16th Edition)

Latest Revision

A Scope

Exclusion list

Voltage ranges

Page 3: Akta dan Peraturan Elektrik

( 8 Markah )

KOD RUJUKAN MUKA: 3 DRP: 6

Page 4: Akta dan Peraturan Elektrik

Soalan 3.

Isikan tempat kosong di bawah berpandukan perbezaan MS IEC 60364 dan I.E.E ?

No Subject MSIEC60364 BS7671 (IEE 16th Edition)

K Selection And Erection of Equipment – Isolation, Switching and Control

Emergency switching

L Earthing Arrengement

Part Part 5-54 Part 5 Chaper %4

Water pipes

Alum as protective bonding

Protective conductors

Insulation for protective conductors

( 10 Markah )

KOD RUJUKAN MUKA: 4 DRP: 6

Page 5: Akta dan Peraturan Elektrik

KEPUTUSAN PENILAIAN

MARKAH : X 100 % 20

ULASAN PENGAJAR :

Tandatangan Pengajar

Nama:

Tarikh :

Page 6: Akta dan Peraturan Elektrik

KOD RUJUKAN MUKA: 5 DRP: 6

Page 7: Akta dan Peraturan Elektrik

Jawapan no 1

The IEE 16th Edition is a familiar standards with Malaysian Engineers.

IEE 16th Edition is known as BS 7671 “Wiring Installation for Buildings”

Jawapan no 2

No

Subject MSIEC60364 BS7671 (IEE 16th Edition)

Latest Revision

2002 1992, 2002 (Amd), 2005 (Draft)

A Scope Residential, industrial, commercial agricultural,

horticultural premises, pre-fab buildings, construction sites, marinas etc. External

consumber installation, extension, alteration etc.

Covers all installation not in exclusion list.

Similar listing of coverage as per MSIEC60364.

Exclusion list

Traction equip., motor vehicles,

Ship, aircraft, street lightings, mines, RF suppressor,

electric fence, lightning etc. Public distribution system, generation, transmission

Traction equip., moto vehicles,Ship, aircraft, ships, motor vehicles,

off shore installations, aircraft, mines, lightning lifts.

Voltage ranges

Up to 1kVa.c. or 1.5Vd.c. Extra low voltage & low voltage

Page 8: Akta dan Peraturan Elektrik

KOD RUJUKAN MUKA: 6 DRP: 6

Jawapan no 3

No Subject MSIEC60364 BS7671 (IEE 16th Edition)

K Selection And Erection of Equipment – Isolation, Switching and Control

Emergency switching

No specific prohibition. Plug & socket as means of emergency switching is prohibited.

L Earthing Arrengement

Part Part 5-54 Part 5 Chaper %4

Water pipes

Use of water pipes as earth electrode are left to the discretion of national committees

Water pipes are not allowed to be used as earth electrodes.

Alum as protective bonding

No specific restriction (left to the discretion of national committees.

Prohibits the use of aluminum or copper clad aluminum as protective bonding conductors.

Protective conductors

Allows aluminium of appropriate cross sectional area.

Protectice conductor of 10mm² or less shall be exclusively copper.

Insulation for protective conductors

No specific prescription. Protective conductor of up to and including 6mm² shall be protected by insulation.