presentation prihoda malaysia sdn bhd

47
WELCOME

Upload: najmi-ahmat

Post on 20-Mar-2017

136 views

Category:

Documents


15 download

TRANSCRIPT

Page 1: Presentation Prihoda Malaysia Sdn Bhd

WELCOME

Page 2: Presentation Prihoda Malaysia Sdn Bhd

What is Fabric Ducting?

- New technology on cool air distribution replacing conventional G.I

- Carries 2 in 1 function as a ducting & diffuser

- Made from 100% polyester fabric with few choices color to suit on the design

Page 3: Presentation Prihoda Malaysia Sdn Bhd

What is Fabric Ducting?

Page 4: Presentation Prihoda Malaysia Sdn Bhd

4 Major Air Side Problem

1 - Short Circuit Problem2 - Condensation3 - Need proper balancing4 - Heavy

Page 5: Presentation Prihoda Malaysia Sdn Bhd

Advantages Fabric Duct

1 – Even distribution2 – No Condensation3 – No need proper balancing4 - Lightweight

Page 6: Presentation Prihoda Malaysia Sdn Bhd

Short Circuit problems

Page 7: Presentation Prihoda Malaysia Sdn Bhd

Lecture Hall FF4 Uitm Puncak Alam

Cooling Load Factor : 40Btu/hr/ft2

3 unit 30 HP Packaged DX SystemAchievement : Temperature during TnC is 20oCCLF 40 is almost same with bedroom.

Page 8: Presentation Prihoda Malaysia Sdn Bhd
Page 9: Presentation Prihoda Malaysia Sdn Bhd

Common Problem in Conventional GI Ducting

- Reduce Productivity- Stress- MC Leave Increase- Customer unhappy- Lost customer trust- Drop branding image- Lost Focus in Class / Mosque- Bad Result scoring

Short Circuit Problem

- Draft Air Flow- Discomfort room condition - Extra cooling load

- Unit Oversize- high electricity bills - High maintenance cost- Loss profit- Wasting Government money- Noisy sound

Page 10: Presentation Prihoda Malaysia Sdn Bhd

Fabric Duct Solutions

Page 11: Presentation Prihoda Malaysia Sdn Bhd

Condensation

- Required Insulation- Spotted mark on the ceiling- Dirty space- Bad smell- Additional repair cost- Impact Company Image- Loss customer trust

Common Problem in Conventional GI Ducting

Page 12: Presentation Prihoda Malaysia Sdn Bhd

Puncak Alam Mosque

Cooling Load Factor : 80Btu/hr/ft2

2 unit 90 HP Air Cooled Dx System with double Cooling CoilsAchievement : • No Condensation at duct, not required insulation.• Entering air 32oC, Outlet air From fabric duct 19oC• First ever project centralized system used at open space

Page 13: Presentation Prihoda Malaysia Sdn Bhd

Need crazy balancing works

- Required skills workers- Extra Cost rent test equipment- The Test Not perform well- Risk of Short Circuit- Inefficient overall Air- Conditioning performance- Waste initial spending cost- Project Delay- Bad Company reputation

Common Problem in Conventional GI Ducting

Page 14: Presentation Prihoda Malaysia Sdn Bhd

Spot Cooling

Page 15: Presentation Prihoda Malaysia Sdn Bhd

Imtiaz Terengganu School Hall

Cooling Load Factor : 115Btu/hr/ft2

2 unit 100HPResult : * Testing & Commissioning Temp : 18oC* Hand Over ceremony only one unit on.

Page 16: Presentation Prihoda Malaysia Sdn Bhd

UIA Gambang Library

Achievement : Only 2 days complete 4 lines of fabric duct installation, compare to almost 2 weeks for GI duct

Page 17: Presentation Prihoda Malaysia Sdn Bhd

The Result

Page 18: Presentation Prihoda Malaysia Sdn Bhd

Heavy (30-60kg/m2 )

- Need strong structure- Extra cost for structure strengthen- Required Strong Lifting Equipment- Longer time to install- Skills Workers Required - More workers needed- Project delay- Risk to Death

Common Problem in Conventional GI Ducting

Page 19: Presentation Prihoda Malaysia Sdn Bhd

Audi Showroom Shah Alam

Cooling Load Factor : 80Btu/hr/ft2

2 unit 30 HP Packaged DX SystemAchievement : No need high cost structure strengthening works.

Page 20: Presentation Prihoda Malaysia Sdn Bhd

BENEFITS – End User• Even cooling distribution• Comfort working environment• Increase productivity• Increase Sales & profit• Good branding Image• Save electricity bill • Quiet operation• Save space• Nice & unique design• Easy Maintenance• 10 years Warranty

Page 21: Presentation Prihoda Malaysia Sdn Bhd

Fabric Ducting Parts of the design

Page 22: Presentation Prihoda Malaysia Sdn Bhd

Fabric Ducting Parts of the

design

Page 23: Presentation Prihoda Malaysia Sdn Bhd

GI DUCT VS FABRIC DUCT• Spot cooling

• Noisy (high velocity)

• Required balancing

• Heavy (30 - 60kg/m2)

• High running cost

• Required Diffusers

• Difficult to clean

• On Site assembly

• Skill installer

• Even distribution

• Quite operation (Laminar Flow)

• Self balancing

• Light Weight 4 - 8kg/m2

• Low running cost

• No Diffusers (2 in 1)

• Easy to clean

• Ready to install

• D.I.Y

Page 24: Presentation Prihoda Malaysia Sdn Bhd

Local Projects

Page 25: Presentation Prihoda Malaysia Sdn Bhd

HELP University

Page 26: Presentation Prihoda Malaysia Sdn Bhd

Lecture Hall Uitm Puncak Alam

Page 27: Presentation Prihoda Malaysia Sdn Bhd

Section 7, Shah Alam Mosque

Page 28: Presentation Prihoda Malaysia Sdn Bhd

Subang Air-Port

Page 29: Presentation Prihoda Malaysia Sdn Bhd

UMP GAMBANG

Page 30: Presentation Prihoda Malaysia Sdn Bhd

Puncak Alam Mosque

Page 31: Presentation Prihoda Malaysia Sdn Bhd

DBKL Batu Muda Hall

Page 32: Presentation Prihoda Malaysia Sdn Bhd

Masjid Kuantan

Page 33: Presentation Prihoda Malaysia Sdn Bhd

Da-Men Mall USJ

Page 34: Presentation Prihoda Malaysia Sdn Bhd

Kayaku Factory

Page 35: Presentation Prihoda Malaysia Sdn Bhd

Masjid Hasanah Bangi

Page 36: Presentation Prihoda Malaysia Sdn Bhd

Masjid Atas Tol Terengganu

Page 37: Presentation Prihoda Malaysia Sdn Bhd

Kompleks PKNS

Page 38: Presentation Prihoda Malaysia Sdn Bhd

Dewan Bomba Penang

Page 39: Presentation Prihoda Malaysia Sdn Bhd

Ecoworld Puncak Alam

Page 40: Presentation Prihoda Malaysia Sdn Bhd

Oversea Project

Page 41: Presentation Prihoda Malaysia Sdn Bhd

Offices

Page 42: Presentation Prihoda Malaysia Sdn Bhd

Lecture Hall

Page 43: Presentation Prihoda Malaysia Sdn Bhd

Temporary Space

Page 44: Presentation Prihoda Malaysia Sdn Bhd

SPORTS

Page 45: Presentation Prihoda Malaysia Sdn Bhd

FITNESS

Page 46: Presentation Prihoda Malaysia Sdn Bhd
Page 47: Presentation Prihoda Malaysia Sdn Bhd

The End