FLOW VISUALISATION FOR GAS SOLID MEASUREMENT USING OPTICAL

TOMOGRAPHY FAN BEAM PROJECTION

MOHD FADZLI B ABD SHAIB

UNIVERSITI TEKNOLOGI MALAYSIA

Page 2: MOHD FADZLI B ABD SHAIB - eprints.utm.myeprints.utm.my/id/eprint/48742/25/MohdFadzliAbdMFKE2014.pdf · mengenalpasti kawasan tersumbat dan saiz, pelbagai meter aliran boleh didapati

FLOW VISUALISATION FOR GAS SOLID MEASUREMENT USING OPTICAL

TOMOGRAPHY FAN BEAM PROJECTION

MOHD FADZLI B ABD SHAIB

A thesis submitted in fulfilment of the

requirements for the award of the degree of

Master of Engineering (Electrical)

Faculty of Electrical Engineering

Universiti Teknologi Malaysia

SEPTEMBER 2014

Page 3: MOHD FADZLI B ABD SHAIB - eprints.utm.myeprints.utm.my/id/eprint/48742/25/MohdFadzliAbdMFKE2014.pdf · mengenalpasti kawasan tersumbat dan saiz, pelbagai meter aliran boleh didapati

iii

In the name of Allah, Most Gracious, Most Merciful

To my beloved and supportive parent, brothers and sisters

To my beloved wife & children

Page 4: MOHD FADZLI B ABD SHAIB - eprints.utm.myeprints.utm.my/id/eprint/48742/25/MohdFadzliAbdMFKE2014.pdf · mengenalpasti kawasan tersumbat dan saiz, pelbagai meter aliran boleh didapati

iv

ACKNOWLEDGEMENT

To Allah the most gracious, most merciful, the all praise worthy. I would like

to express my great appreciation to my respectful supervisor, Prof. Dr. Ruzairi Hj.

Abdul Rahim. Without his valuable guidance, motivation and constant endeavour

throughout the study, this research would not have been successful.

My special gratitude goes to my colleague Dr Zarina Bt Mohd Muji, Dr

Razali B Tomari, and Mr Ariffuddin B Joret for providing technical guidance and

helpful suggestions that helped me to conduct this research.

Thank you to my parents for their unconditional support. Finally, but most

importantly, I wish to thank my wife Siti Fatimah Bt Jamalludin and my children

Muhammad Mikhail Iman B Mohd Fadzli and Nur Qaisara Iman Bt Mohd Fadzli and

Nurlisa Qistina Iman Bt Mohd Fadzli for their full support, love and understanding

throughout this wonderful journey.

Page 5: MOHD FADZLI B ABD SHAIB - eprints.utm.myeprints.utm.my/id/eprint/48742/25/MohdFadzliAbdMFKE2014.pdf · mengenalpasti kawasan tersumbat dan saiz, pelbagai meter aliran boleh didapati

v

ABSTRACT

In granules manufacturing industry, a real time monitoring is vital to observe

the distribution of solid and gas mixture in pipelines. For solid and gas mixture such

as pharmaceutical and grain production, the tiny pills and grains are poured through

industrial chutes and silos in mass quantities. Nevertheless, the uncontrolled large

scale flow can cause blockage in the pipeline and consequently can cause severe

limited production efficiency. To determine the blockage area as well as its size,

various flow meters are available in the market. However, most of the flow meters

are intrusive and invasive; therefore can disrupt material flow. The optical

tomography system technique is one of the methods to be adopted because of the

ability of the system to observe material flow non-intrusively, hence determine the

affected blockage area. In this research, alternate arrangements of 16 pairs of optical

sensors which consist of transmitters and receivers have been mounted on a 10cm

acrylic pipeline. Since the fan beam projection technique has been used, infrared

Light Emitting Diode (LED) and photodiode with greater angle of projection and

response were chosen. A specially designed jig has been developed for sensor

positioning to ensure they are exactly on the periphery of the pipeline. Most previous

researchers utilised digital timing and Data Acquisition System (DAS) units to

control the projection and receiving unit of the optical tomography system. In this

research, a circuit integrated with a dsPIC30F6014A microcontroller has been

designed for controlling the projection of light by transmitters and the receiving

signal of receivers. To operate the dsPIC30F6014A microcontroller together with the

designed circuit, C programming language via MicroC compiler is applied. For

image reconstruction, Linear Back Projection (LBP) has been applied via Visual

Basic 6. Different flow regimes have been tested and analysed thoroughly to observe

the overall performance of the system. The results obtained show that the optical

tomography system developed is capable of observing multiple flows with different

flow regimes; hence successfully determine blockage area of the solid gas flow.

Apparently, the proposed single dsPIC30F6014A microcontroller usage indicates its

ability to control acquisition process effectively with 480 µs sampling time rate.

Page 6: MOHD FADZLI B ABD SHAIB - eprints.utm.myeprints.utm.my/id/eprint/48742/25/MohdFadzliAbdMFKE2014.pdf · mengenalpasti kawasan tersumbat dan saiz, pelbagai meter aliran boleh didapati

vi

ABSTRAK

Dalam industri pembuatan bijirin, pemantauan masa nyata adalah penting

bagi memerhatikan proses percampuran pepejal dan gas dalam paip. Untuk campuran

pepejal dan gas seperti farmaseutikal dan pengeluaran bijirin, pil-pil yang kecil dan

bijirin di tuangkan melalui pelongsor industri dan silo dalam kuantiti yang banyak.

Walau bagaimanapun, aliran dalam skala besar tidak terkawal boleh menyebabkan

saluran paip tersumbat dan seterusnya menghadkan pengeluaran bahan efisien. Bagi

mengenalpasti kawasan tersumbat dan saiz, pelbagai meter aliran boleh didapati

dalam pasaran. Walau bagaimanapun, kebanyakan meter aliran mengganggu

pengaliran dan bersifat invasif; boleh mengganggu pengaliran bahan. Teknik sistem

tomografi optik adalah salah satu kaedah yang boleh digunapakai kerana keupayaan

sistem untuk melihat aliran bahan tanpa mengganggu pengaliran, dengan itu dapat

mengenalpasti kawasan tersumbat terlibat. Dalam kajian ini, 16 pasang sensor optik

terdiri daripada pemancar dan penerima telah dipasang pada paip akrilik diameter 10

cm. Memandangkan teknik unjuran berbentuk kipas digunakan, Diod Pemancar

Cahaya (LED) radiasi infra merah dan fotodiod dengan sudut lebih besar telah

dipilih. Jig direka khas telah dibangunkan bagi memastikan kedudukan sensor

berada disekeliling paip. Kebanyakan penyelidik sebelum ini menggunakan litar

masa digital dan Sistem Pemerolehan Data (DAS) untuk mengawal unit unjuran dan

penerimaan sistem tomografi optik. Dalam kajian ini, penggabungan litar bersama

dsPIC30F6014A mikropengawal telah direka untuk mengawal unjuran cahaya untuk

pemancar dan penerimaan isyarat untuk penerima. Bagi pengoperasian

dsPIC30F6014A mikropengawal dan litar yang direka, bahasa pengaturcaraan C

melalui pengkompil MicroC digunakan. Untuk pembinaan semula imej, Unjuran

Kembali Linear (LBP) telah digunakan menggunakan Visual Basic 6. Pelbagai

model aliran telah diuji dan dianalisis dengan teliti untuk melihat prestasi

keseluruhan sistem. Dari keputusan yang diperolehi, sistem tomografi optik mampu

digunakan untuk melihat pelbagai aliran di kawasan berbeza, seterusnya dapat

menentukan kawasan yang tersumbat. Secara jelasnya, penggunaan mikropengawal

dsPIC30F6014A tunggal menunjukkan keupayaan bagi pengambilan data dengan

kadar masa 480 µs bagi persampelan data.

Page 7: MOHD FADZLI B ABD SHAIB - eprints.utm.myeprints.utm.my/id/eprint/48742/25/MohdFadzliAbdMFKE2014.pdf · mengenalpasti kawasan tersumbat dan saiz, pelbagai meter aliran boleh didapati

vii

TABLE OF CONTENTS

CHAPTER TITLE PAGE

DECLARATION ii

DEDICATION iii

ACKNOWLEDGEMENT iv

ABSTRACT v

ABSTRAK vi

TABLE OF CONTENTS vii

LIST OF TABLES xii

LIST OF FIGURES xiv

LIST OF SYMBOLS xvii

LIST OF ABBREVIATIONS xviii

LIST OF APPENDICES xx

1 INTRODUCTION 1

1.1 Background Problem 2

1.2 Problem Statements 3

1.3 Importance of Study 5

1.4 Research Objectives 6

1.4.1 Specific Objectives 6

Page 8: MOHD FADZLI B ABD SHAIB - eprints.utm.myeprints.utm.my/id/eprint/48742/25/MohdFadzliAbdMFKE2014.pdf · mengenalpasti kawasan tersumbat dan saiz, pelbagai meter aliran boleh didapati

viii

1.5 Research Scopes 6

1.6 Organisation of the Thesis 7

2 LITERATURE REVIEW 9

2.1 Introduction to Process Tomography 9

2.2 Types of Tomography Sensors 10

2.2.1 X-Ray Tomography 10

2.2.2 Electrical Capacitance Tomography (ECT) 11

2.2.3 Electrical Impedance Tomography (EIT) 12

2.2.4 Magnetic Induction Tomography (MIT) 13

2.2.5 Ultrasonic Tomography 14

2.2.6 Optical Tomography 16

2.3 Type of Projections 17

2.4 Research in Optical Tomography 18

2.5 Image Reconstruction Algorithm 26

2.6 Summary 28

3 HARDWARE DEVELOPMENT 29

3.1 Introduction 29

3.2 Sensors Selection 30

3.2.1 Transmitter Selection 32

3.2.2 Receiver Selection 34

3.3 Verification of Coverage Area for Transmitters and

Receivers 36

3.3.1 Experimental Set-Up for Determination of Sensor

Coverage 36

3.4 Arrangement of Sensors for Transmitters and Receivers 40

Page 9: MOHD FADZLI B ABD SHAIB - eprints.utm.myeprints.utm.my/id/eprint/48742/25/MohdFadzliAbdMFKE2014.pdf · mengenalpasti kawasan tersumbat dan saiz, pelbagai meter aliran boleh didapati

ix

3.5 Circuit Design for Transmitters and Receivers of

Optical Tomography 41

3.6 Printed Circuit Board (PCB) and Fixture Arrangement 44

3.7 Summary 45

4 SOFTWARE DEVELOPMENT 47

4.1 Introduction 47

4.2 Data Acquisition by means of Microcontroller

dsPIC30F6014A 48

4.3 Graphical User Interface (GUI) for Simulation

and Image Reconstruction 52

4.4 Sensitivity Maps for Optical Tomography System 56

4.5 Image Reconstruction via Linear Back Projection (LBP)

Technique 59

4.6 Filtration via Filtered Back Projection Technique (FBP) 62

4.7 Viewing Concentration Profile of Solid-Gas Flow 63

4.8 Graphical User Interface (GUI) for Data Analysis 65

4.9 Summary 66

5 RESULT ANALYSIS 67

5.1 Introduction 67

5.2 Important Parameters for Analysis 67

5.2.1 Means Square Error (MSE) 68

5.2.2 Peak Signal to Noise Ratio (PSNR) 68

5.2.3 Percentage Area Error 69

5.2.4 Concentration of Solid 70

5.3 Simulation Analysis for Various Types of Flow 70

Page 10: MOHD FADZLI B ABD SHAIB - eprints.utm.myeprints.utm.my/id/eprint/48742/25/MohdFadzliAbdMFKE2014.pdf · mengenalpasti kawasan tersumbat dan saiz, pelbagai meter aliran boleh didapati

x

5.3.1 Simulation for Full-Flow Model 70

5.3.2 Simulation for Half-Flow Model 71

5.3.3 Simulation for Quarter-Flow Model 73

5.3.4 Simulation for Middle-Circular Flow Model 74

5.3.5 Simulation for Two Different Locations of

Round-Flow Model 75

5.3.6 Simulation for Square Flow Model 76

5.4 Comparing the Image Quality for Different Types of Flow 77

5.5 Analysis of Image Obtained from Developed Optical

Tomography System 81

5.5.1 Full-Flow Model Image Obtained from

Hardware of Optical Tomography System 82

5.5.2 Half-Flow Model Image Obtained from

hardware of Optical Tomography System 83

5.5.3 Quarter-Flow Model Image Obtained from

Hardware of Optical Tomography System 87

5.5.4 Middle-Circular Flow Model Image Obtained from

Hardware of Optical Tomography System 88

5.5.5 Two Different Locations of Round Model Image

Obtained from Hardware of Optical Tomography

System 93

5.5.6 Polygon Shape Detection (Square Shape) from

Hardware of Optical Tomography System 96

5.5.7 Polygon Shape Detection (Triangle Shape) from

Hardware of Optical Tomography System 99

5.6 Analysis of Overall Performance of the System Based on

Different Types of Image Flow 102

5.7 Analysis of the Image Obtained from Rice Flow

Experiment from Developed Optical Tomography

System 106

5.8 Summary 107

Page 11: MOHD FADZLI B ABD SHAIB - eprints.utm.myeprints.utm.my/id/eprint/48742/25/MohdFadzliAbdMFKE2014.pdf · mengenalpasti kawasan tersumbat dan saiz, pelbagai meter aliran boleh didapati

xi

6 CONCLUSIONS AND RECOMMENDATIONS 110

6.1 Conclusions 110

6.2 Research Contribution 111

6.3 Recommendation for future works 112

REFERENCES 114

Appendices A - G 119 - 138

Page 12: MOHD FADZLI B ABD SHAIB - eprints.utm.myeprints.utm.my/id/eprint/48742/25/MohdFadzliAbdMFKE2014.pdf · mengenalpasti kawasan tersumbat dan saiz, pelbagai meter aliran boleh didapati

xii

LIST OF TABLES

TABLE NO. TITLE PAGE

3.1 Different models of infrared LED 32

3.2 Different models of photodiode 34

4.1 List of input/output ports for dsPIC30F6014A 49

4.2 List of input ports used for activation of transmitters 49

4.3 List of ADC ports for dsPIC30F6014A 50

5.1 Simulation analysis for full-flow model 71

5.2 Simulation analysis for half-flow model 72

5.3 Simulation for quarter-flow model 73

5.4 Simulation for middle-circular flow model 75

5.5 Simulation for two different locations of round-flow model 76

5.6 Simulation for square-flow model 77

5.7 Image of full-flow model 82

5.8 Image for half-flow (black flow) model 84

5.9 Image for half-flow (white flow) model 86

5.10 Image for quarter-flow (black flow) model 88

5.11 Image for quarter-flow (white flow model) 89

5.12 Image for middle-circular flow (black flow) model 91

Page 13: MOHD FADZLI B ABD SHAIB - eprints.utm.myeprints.utm.my/id/eprint/48742/25/MohdFadzliAbdMFKE2014.pdf · mengenalpasti kawasan tersumbat dan saiz, pelbagai meter aliran boleh didapati

xiii

5.13 Image for middle-circular flow (white flow) model 92

5.14 Image for two different locations of

round-flow (black flow) model 94

5.15 Image for two different locations of

round-flow (white flow) model 95

5.16 Image for square-flow (black flow) model 96

5.17 Image for square-flow (white flow) model 98

5.18 Image for triangle-flow (black flow) model 100

5.19 Image for triangle-flow (white flow) model 101

5.20 Image for Rice Full Flow Experiment 107

5.21 Image for Rice Half Flow Experiment 108

Page 14: MOHD FADZLI B ABD SHAIB - eprints.utm.myeprints.utm.my/id/eprint/48742/25/MohdFadzliAbdMFKE2014.pdf · mengenalpasti kawasan tersumbat dan saiz, pelbagai meter aliran boleh didapati

xiv

LIST OF FIGURES

FIGURE NO. TITLE PAGE

2.1 Basic tomography system 10

2.2 Cross-sectional view of ECT sensor with 12 electrodes 12

2.3 Concept of EIT systems 13

2.4 MIT system topology 14

2.5 Concept of Ultrasonic tomography 15

2.6 Parallel projection (a) general concept

(b) tomography application 17

2.7 Fan beam projection (a) general concept

(b) tomography application 18

2.8 Parallel configuration for optical tomography 19

2.9 Configuration of two orthogonal and two rectilinear

projections 20

2.10 Optical stopper and alternate arrangement of Tx and Rx 21

2.11 Combination of rectilinear and orthogonal projection

on the same plane 22

2.12 Experiment set up for study of the flames concentrations 23

2.13 Fan Beam Arrangement (a) 4 Light sources, 15 beams;

(b) 15 Light sources, 5 beams; (c) 15 Light sources, 15 beams 23

2.14 Fan Beam arrangement with 32 pairs of infrared emitters

and photodiode receivers 24

2.15 Combination of parallel and fan beam projection 25

3.1 Topology for optical tomography system 30

Page 15: MOHD FADZLI B ABD SHAIB - eprints.utm.myeprints.utm.my/id/eprint/48742/25/MohdFadzliAbdMFKE2014.pdf · mengenalpasti kawasan tersumbat dan saiz, pelbagai meter aliran boleh didapati

xv

3.2 Electromagnetic wavelength 31

3.3 Spectral range for OSRAM-SFH 485P &

OSRAM-SFH484-2 33

3.4 Spectral range for OSRAM-SFH203PFA &

OSRAM-SFH213-FA 35

3.5 Diagram of angle for transmitter and receiver’s IR LED 37

3.6 Graph showing signal from transmitter and receiver 38

3.7 Graph showing receiver’s response for radius of 5cm 39

3.8 Graph showing receiver’s response for radius of 10 cm 39

3.9 Arrangement of Tx and Rx around the acrylic cylinder 40

3.10 Light projection circuit 41

3.11 Signal conditioning circuit 43

3.12 New design for sensor jig, (a) single jig design,

(b) jig embedded in acrylic cylinder 44

3.13 Integration of PCB and optical tomography jig, (a) front view,

(b) upper view 45

4.1 Input/output port arrangements for dsPIC30F6014A 48

4.2 Flowchart of port usage for data acquisition process 51

4.3 Representation of GUI for optical tomography system 52

4.4 Tomogram after filtration process 52

4.5 Array set of pixel value based on reading of sensors

from the hardware of optical tomography system 54

4.6 Flowchart for communication between VB6 and

dsPIC30F6014A microcontroller 55

4.7 Projection paths for Tx2 and Rx7 57

4.8 Total Projection paths for Tx0 and Rx0 until Rx15 58

4.9 LPBA and fan beam projection, (a) general concept,

(b) projection beam summation 59

4.10 Maximum voltage received by receiver 60

Page 16: MOHD FADZLI B ABD SHAIB - eprints.utm.myeprints.utm.my/id/eprint/48742/25/MohdFadzliAbdMFKE2014.pdf · mengenalpasti kawasan tersumbat dan saiz, pelbagai meter aliran boleh didapati

xvi

4.11 Attenuated voltage received by receiver 61

4.12 Flowchart for image reconstruction 64

4.13 GUI developed via MATLAB for analyzed of the system 65

5.1 Comparison of material distribution profile between

simulation and real image 78

5.2 Comparison of area error between simulation and real image 79

5.3 Comparison of MSE between simulation and real image 80

5.4 Comparison of PSNR between simulation and real image 80

5.5 Static flow experiment set up 81

5.6 Material distributions for different types of flow 103

5.7 Area errors for different types of flow 104

5.8 MSE for different types of flow 105

5.9 PSNR for different types of flow 105

5.10 Rice Flow Experiment, (a) Full flow, (b) Half flow 106

Page 17: MOHD FADZLI B ABD SHAIB - eprints.utm.myeprints.utm.my/id/eprint/48742/25/MohdFadzliAbdMFKE2014.pdf · mengenalpasti kawasan tersumbat dan saiz, pelbagai meter aliran boleh didapati

xvii

LIST OF SYMBOLS

V - Voltage

Ω - Ohm

3D - Three Dimension

dB - Decibel

s - Second

k - Kilo

M - Mega

mm - Milimeter

nm - Nano Meter

Av - Gain

V+ - Non-inverting Input

V- - Inverting Input

Vin - Input voltage at the receiver

Page 18: MOHD FADZLI B ABD SHAIB - eprints.utm.myeprints.utm.my/id/eprint/48742/25/MohdFadzliAbdMFKE2014.pdf · mengenalpasti kawasan tersumbat dan saiz, pelbagai meter aliran boleh didapati

xviii

LIST OF ABBREVIATIONS

ADC - Analogue to Digital Conversion

AGC - Averaging Group Colour

CT - Computed Tomography

DAQ - Data Acquisition

DAS - Data Acquisition System

ECT - Electrical Capacitance Tomography

EIT - Electrical Impedance Tomography

FBP - Filtered Back Projection

GND - Ground

GUI - Graphical User Interfaces

Hz - Hertz

I2C - Inter-Integrated Circuit

IC - Integrated Circuit

IR - Infrared Light Emitting Diode

kHz - Kilo Hertz

LBP - Linear Back Projection

LBPA - Linear Back Projection Algorithm

LED - Light Emitting Diode

MHz - Mega Hertz

Page 19: MOHD FADZLI B ABD SHAIB - eprints.utm.myeprints.utm.my/id/eprint/48742/25/MohdFadzliAbdMFKE2014.pdf · mengenalpasti kawasan tersumbat dan saiz, pelbagai meter aliran boleh didapati

xix

MIT - Magnetic Induction Tomography

MSE - Mean Square Error

OP-AMP - Operational Amplifier

PC - Personal Computer

PCB - Printed Circuit Board

PCI - Peripheral Component Interconnect

PIC - Peripheral Interface Controller

PSNR - Peak Signal To Noise Ratio

PVC - Poly(vinyl chloride)

Rx - Receiver

SIE - Space Image Evaluating

Tx - Transmitter

UART - Universal Asynchronous Receiver/Transmitter

USB - Universal Serial Bus

VB - Visual Basic

Page 20: MOHD FADZLI B ABD SHAIB - eprints.utm.myeprints.utm.my/id/eprint/48742/25/MohdFadzliAbdMFKE2014.pdf · mengenalpasti kawasan tersumbat dan saiz, pelbagai meter aliran boleh didapati

xx

LIST OF APPENDICES

APPENDIX TITLE PAGE

A Visitation Letter to “Faiza Beras Sdn Bhd” 118

B Datasheet of SHF485P 119

C Datasheet of SFH203PFA 121

D Datasheet of dsPIC30F6014A 123

E MicroC Compiler Programming 124

F VB6 Programming for Image Reconstruction 128

G Matlab Programing 135

H List of Publications and Awards 137

Page 21: MOHD FADZLI B ABD SHAIB - eprints.utm.myeprints.utm.my/id/eprint/48742/25/MohdFadzliAbdMFKE2014.pdf · mengenalpasti kawasan tersumbat dan saiz, pelbagai meter aliran boleh didapati

CHAPTER 1

INTRODUCTION

The word tomography derives from the Greek and means a cut picture or

image. From an engineering perspective, tomography is about obtaining information

or data on the internal structure of an object without the need to invade or disrupt

material flow.

Even though the tomography field is considered as mature technology and

offers only low-resolution imaging, it remains popular thanks to its ability to

penetrate the internal structure of the object without the need to slice the object.

Tomography was first used for medical examination purposes, and gradually its

industrial application occurred where online monitoring is concerned (Dyakowski et

al, 2000).

Several tomography sensors exist and they are divided into “hard field” and

“soft field” sensors. Hard field sensors are equally sensitive to parameters measured

in all positions throughout the measurement volume and its sensitivity is independent

of the distribution inside and outside the measurement region whereas with soft field

sensors the sensitivity of the measured parameter depends on position in the

measurement volume as well as on the distribution of parameters inside and outside

Page 22: MOHD FADZLI B ABD SHAIB - eprints.utm.myeprints.utm.my/id/eprint/48742/25/MohdFadzliAbdMFKE2014.pdf · mengenalpasti kawasan tersumbat dan saiz, pelbagai meter aliran boleh didapati

2

this region (Johansen et al, 1996). An example of a hard field sensor is the X-ray

(earliest technique) and an electrical capacitance tomography sensor (ECT) is an

example of soft field sensors.

1.1 Background Problem

Process tomography has begun to spread extensively in industrial field

research which uses different tomography techniques for monitoring flows of various

types of component mixture inside pipelines. Indeed, study of the flow of solid and

gas mixtures is vital and the tomography technique can improve the overall

performance of the industrial process. The important feature of process tomography

is its capability in terms of providing information for multiphase flow rates and

material distribution or concentration profile inside pipelines in real time.

An industrial tomography system must have significant characteristics such

as high speed of data acquisition, good responses (capable of online monitoring) and

low cost compared with the current flow meter industry. This is vital since most of

the material flow inside a pipeline moves at very high speed and requires very good

responses, especially particle flow in the food and chemical industries.

The right data acquisition system, besides very high speed, must also have

sufficient analogue input and digital output and be able to be integrated with

tomography sensors and computers. Most previous research has utilised a

combination of the PIC microcontroller or designed circuit and the data acquisition

system (DAQ) in developing a tomography system (Abdul Rahim, 2005; Zheng et al,

2008). DAQ cards have been used for interfacing the sensor device in computers for

better image reconstruction. Even though the DAQ card has often been selected by

researchers, it is not a good choice in terms of the cost-effectiveness of the whole

Page 23: MOHD FADZLI B ABD SHAIB - eprints.utm.myeprints.utm.my/id/eprint/48742/25/MohdFadzliAbdMFKE2014.pdf · mengenalpasti kawasan tersumbat dan saiz, pelbagai meter aliran boleh didapati

3

system. The price of DAQ cards ranges from RM 6 k to RM 20 k per unit (retail

value from official website National Instrument http://www.ni.com/data-

acquisition/), which is exorbitant. This is at odds with the original aim of producing a

sensor device using low-cost apparatus (Minagawa et al, 2012). Alternative methods

of data conversion should be considered. Muji (2012) used a different combination

of a peripheral interface controller (PIC) and I2C protocol to develop an optical

tomography system. This method is much better than the DAQ system in terms of

cost-effectiveness. The I2C protocol is needed for combination of several PICs. This

combination is required since a single PIC is unable to provide enough analogue

input and digital output for most tomography systems. Using the I2C protocol could

be intricate and complicated, however. Hence, an alternative microcontroller should

be chosen to fulfil the above-mentioned needs. In 2001, Microchip released a dsPIC

series of chips with a 16-bit microcontroller instead of an 8-bit for normal PIC. This

dsPIC can cater for large numbers of analogue and digital input/output ports, thus

eliminating the need for an I2C protocol.

1.2 Problem Statement

The production, processing and transport of particulate or granular

materials such as minerals, powders or cereals, is of immense industrial importance.

A pneumatic conveying system is a common process to transfer this bulk material

through an enclosed pipeline. However, in pneumatic conveying system often could

cause blockage due to uncontrolled large scale and condense flow of the material

inside the pipeline; hence could adversely affect the whole productivity. There are

several current flow meters available to detect material flow and identifying blockage

area inside the pipeline. However, most of this equipment is intrusive with exorbitant

price. The developed optical tomography is the cost effective option to observe and

identifying the blockage area without need to invade the material flow.

Page 24: MOHD FADZLI B ABD SHAIB - eprints.utm.myeprints.utm.my/id/eprint/48742/25/MohdFadzliAbdMFKE2014.pdf · mengenalpasti kawasan tersumbat dan saiz, pelbagai meter aliran boleh didapati

4

In gravitational driven flow of granular material, the pipeline used has its

minimum size of diameter so that conveying of the bulk material could flow easily.

In the same way, the developed optical tomography fixture should be the same size

with the diameter of the pipeline to capture the data without disrupts the material

flow. However, most of the develop optical tomography by previous researcher do

not meet the minimum size of the pipe line. Instead, the designed fixture is lower size

in diameter compared with the diameter of the pipeline used in industry. This will

limit the capability of the sensor observing the flow with larger size of the pipeline.

For construction of optical tomography system, most of previous researcher

utilizing the usage of DAQ card along with projection circuit for transmitting and

receiving signals. Besides, the combination of several microcontrollers is one of the

options for researchers in this area to manage the system with higher number of input

and output. However, both of this approach may not fulfill the main aims which are

to produce low cost and uncomplicated flow meter towards industrial needs.

Over the past several years, observing black material flows is always an

option for many of the researcher. However, the capability of this system to monitor

only one type of color range could restrain its application towards certain industries

only.

.

Page 25: MOHD FADZLI B ABD SHAIB - eprints.utm.myeprints.utm.my/id/eprint/48742/25/MohdFadzliAbdMFKE2014.pdf · mengenalpasti kawasan tersumbat dan saiz, pelbagai meter aliran boleh didapati

5

1.3 Importance of Study

In the chemical and food industries, several types of material or foods need to

be processed or produced in liquid solid form such as particles and granules. In terms

of solid forms, the material might be presented as raw material or final products.

Identifying the internal characteristics of solid flows along the conveying system is

essential for observation of the overall performance of the process flow. This can be

done by obtaining the concentration profile or distribution of particles inside the

pipeline. Most of the pipeline or conveying system of solid flow is opaque, and the

flow pattern cannot be observed with the naked eye. Hence, non-intrusive monitoring

flow is needed to observe solid flow in gas medium. This is important to avoid flow

disruption or collision between the material and the monitoring device.

Tomography is the most effective technology for observing the internal

characteristics of solid flow without interrupting the internal process flow. There are

several tomography sensing approaches but to date there is no specific online

monitoring system for monitoring solids in a pneumatic conveying pipeline (Zheng

et al, 2010).

The optical tomography system is one of the most popular techniques for

observing the solid flow inside the pipeline. Most research utilises a pipeline which

has a small diameter of 60mm as medium of solid and gas flow (Chan, 2002; Leong

et al, 2005). A personal visit to a rice manufacturing industry in Malaysia (Appendix

A) revealed, however, that the minimum diameter of the pipeline applied in this kind

of industry is actually 100mm. This suggests that the ability of optical sensors to

observe material flow should be examined in the case of pipelines with a bigger

diameter. The complexity of the overall circuit will also be simplified by the usage

of a dsPIC30F6014A microcontroller. Most of the manufacturing industries handle

material which is generally dark or bright in colour. The performance of the sensors

on different colours is thoroughly examined here to observe the compatibility of the

Page 26: MOHD FADZLI B ABD SHAIB - eprints.utm.myeprints.utm.my/id/eprint/48742/25/MohdFadzliAbdMFKE2014.pdf · mengenalpasti kawasan tersumbat dan saiz, pelbagai meter aliran boleh didapati

6

system. It is hoped that the result will help other researchers to contribute to the

development and application of optical tomography in real industry.

1.4 Research Objectives

The aim of this research is to develop an optical tomography system using fan

beam projection configuration and an online monitoring system for solid-flow

visualisation.

1.4.1 Specific Objectives

This researched aimed to meet the following objectives:

i. Design optical tomography measurement hardware

ii. Develop tomography software display

iii. Integrate the software and hardware for verification purposes

iv. Test and verify the ability of the system to observe different flow models with

black and white colours.

1.5 Research Scope

(i) Design of a Sensor Fixture

The important things when deciding on a sensor fixture are the sensors'

physical parameters, light projection angle, type of material suitable for

Page 27: MOHD FADZLI B ABD SHAIB - eprints.utm.myeprints.utm.my/id/eprint/48742/25/MohdFadzliAbdMFKE2014.pdf · mengenalpasti kawasan tersumbat dan saiz, pelbagai meter aliran boleh didapati

7

constructing a fixture that suits the desired system and integration of the

fixture with the designed circuit.

(ii) Sensor Selection

The type of sensors for transmitters and receivers needs to be decided. In this

optical tomography system, infrared (IR) LED is selected for the transmitters

and a photo-detector LED for the receivers.

(iii) Circuit design

Current for transmitter, amplifier circuit for receivers and microcontroller

unit for digital timing are required, plus data conversion from analogue to

digital form.

(iv) Software design for real-time image reconstruction

The software needed has two parts. The first part involves programming with

a MicroC compiler to give instructions to the microcontroller for activation or

deactivation of transmitters and data conversion at the receiver side. The

second part involves developing an algorithm for image reconstruction using

Visual Basic 6.

1.6 Organisation of Thesis

Chapter 1 presents an introduction to process tomography, the research’s

background problem, the problem statement, the importance of the study, the

research objectives and the scope of the study.

Page 28: MOHD FADZLI B ABD SHAIB - eprints.utm.myeprints.utm.my/id/eprint/48742/25/MohdFadzliAbdMFKE2014.pdf · mengenalpasti kawasan tersumbat dan saiz, pelbagai meter aliran boleh didapati

8

Chapter 2 lists several common types of tomographic techniques and the

general principles of optical tomography.

Chapter 3 explains optical tomography modelling and hardware design. This

includes optical sensor arrangement, mounting techniques, signal conditioning

circuits and data acquisition systems.

Chapter 4 details the software development for generating a pulse for

activation and deactivation of the transmitter, timing sequence, data acquisition and

image reconstruction.

Chapter 5 describes the image obtained from different types of flow models.

Comparisons of the concentration value of the different models are presented.

Chapter 6 concludes, mention state research contribution and suggests further

work to improve on the present study.

Page 29: MOHD FADZLI B ABD SHAIB - eprints.utm.myeprints.utm.my/id/eprint/48742/25/MohdFadzliAbdMFKE2014.pdf · mengenalpasti kawasan tersumbat dan saiz, pelbagai meter aliran boleh didapati

114

REFERENCES

Abdul Rahim, R. (1996). A Tomography Imaging System For Pneumatic

Conveyors Using Optical Fibres. Sheffield Hallam University: Ph.D. Thesis.

Abdul Rahim, R., Green, R.G. (1998).Optical Fibre sensor for process tomography,

Control Engineering Practice 6. 1365-1371

Abdul Rahim, R., Pang, J.F., Chan Kok San(2003).Optical tomography

sensor configuration using two orthogonal and two rectilinear projection

arrays. Flow Measurement and Instrumentation. Volume 16, 327–340

Abdul Rahim, R., Rahiman,M.H.F. and Chan, K. S. (2004). Monitoring Liquid /

Gas Flow Using Ultrasonic Tomography. Proc. 3rd International

Symposium on Process Tomography in Poland. Lodz, Poland. 130-133. 11.

Abdul Rahim, R., Pang, J.F., Kok San Chan(2005).Optical tomography

sensor configuration using two orthogonal and two rectilinear projection

arrays. Flow Measurement and Instrumentation.Volume 16, Issue 5, Pages

327–340.

Abdul Rahim, R., L.C. Leong, K.S. Chan, M.H. Rahiman, Pang, J.F., (2008).

Real time mass flow rate measurement using multiple fan beam optical. ISA

Transactions.47, 3–14

Arshad Amari, Hudabiyah (2012). Multiphase Flow Imaging Using Ultrasonic

Tomography, Thesis 2012,UTM

Alain Hore’, Djemel Ziaou(2010). Image quality metrics: PSNR vs. SSIM.

20th International Conference on Pattern Recognition. 2366 - 2369

Beck, M.S., Green, R.G. (1996). Process tomography: a European innovation and

its applications. Meas. Sci. Technol. 7, 215–224.

Beck, M.S., Green, R.G. and Thorn, R. (1987). Non-intrusive measurement of solids

mass flow in Pneumatic Conveying. J. Phys. E: Sci. Instrum. Volume 20, 835

Chan, K.S. (2002). Real Time Image Reconstruction For Fan Beam Optical

Tomography System. Master Engineering.UTM

Chen,J., Hou.,D., Zhang,T. and Zhou,Z. (2005). Near infrared laser computed

Tomography test-system design and application. Flow Measurement and

Instrumention.16(5), 321-325

Page 30: MOHD FADZLI B ABD SHAIB - eprints.utm.myeprints.utm.my/id/eprint/48742/25/MohdFadzliAbdMFKE2014.pdf · mengenalpasti kawasan tersumbat dan saiz, pelbagai meter aliran boleh didapati

115

D T Nguyen,CJin, A Thiagalingam and A L McEwan(2012). A review on electrical

impedance tomography for pulmonary perfusion imaging. Physiol. Meas., 33

695–706

Dugdale.P., Green,R.G., Hartley,A.J., Jackson,G.G. and Landauro,J.(1992).Optical

Sensors for Process Tomography.ECAPT.Manchester,26-29.

Green R G, Horbury N M, Abdul Rahim R, Dickin F J, Naylor B D and Pridmore T

P(1995). Optical fibre sensors for process tomography. Meas. Sci. Technol.

Volume 6,1995,1699-1704

Johansen, G.A., T Frøystein, B T Hjertakery and Ø Olsen(1996). A dual sensor flow

imaging tomographic system.Meas. Sci. Technol. 7,297–307.

Goh,C.L.(2005).Real Time Solids Mass Flow Rate Measurement Via Ethernet Based

Optical Tomography System.Master Engineering,Universiti Teknologi

Malaysia.

Green R.G., N M Horburyt, Abdul Rahim, R., F J Dickins,B D Naylort and T P

Pridmoret(1995). Optical fibre sensors for process tomography. Measurement

Science and Technology. 6, 1699-1704

Green, R.G., Rahmat, M.F., Evans,K., Goude, A., Henry,M. and Stone, J.A.R.(1997).

Concentration Profilesof dry powders in a gravity conveyors using

Electrodynamics tomography system. Measurement Science and

Technology.8, 192-197

H Griffiths(2001). Magnetic induction tomography. Meas. Sci. Technol. 12, 1126–

1131

Ibrahim, S. (2000).Measurement of Gas Bubbles in a Vertical Water Column Using

Optical Tomography, Doctor Philisophy, Sheffield Hallam University

Ibrahim, S., Green, R.G., K Dutton, K Evan, Abdul Rahim, R. (1999). Optical sensor

configurations for process tomography. Meas. Sci. Technol. Volume 10, 107

Leong, L.C. (2005). Implementation of multiple fan beam projection technique

in optical fiber process tomography. Master Engineering.Universiti

Teknologi Malaysia

Liangzhong Xiang, Bin Han, Colin Carpenter, Guillem Pratx, Yu Kuang, and Lei

Xing(2013). X-ray acoustic computed tomography with pulsed x-ray beam

from a medical linear accelerator. Medical Physics Letter. Volume 40, No.1

McKeen, T. R. and Pugsley, T. S. (2002). The Influence of Permittivity Models on

Phantom Images Obtained From Electrical Capacitance Tomography.

Measurement Science Technology. Vol 13, 1822–1830.

Microchip Technology Inc. (2011), dsPIC30F6011A/6012A/6013A/6014A Data

Page 31: MOHD FADZLI B ABD SHAIB - eprints.utm.myeprints.utm.my/id/eprint/48742/25/MohdFadzliAbdMFKE2014.pdf · mengenalpasti kawasan tersumbat dan saiz, pelbagai meter aliran boleh didapati

116

Sheet, Retrieved on 28th October 2013 from

http://ww1.microchip.com/downloads/en/DeviceDoc/70143E.pdf

Mohamad,E.J.(2006).Flame Imaging using Laser Based Transmission Tomography.

Sensors and Actuators A: Physical.127 (2), 332-339.

Mohamad, E.J., Fazlul Rahman Mohd Yunus, Abdul Rahim, R. & Chan Kok

Seong(2011). Hardware Development Of Electrical Capacitance

Tomography for Imaging a Mixture of Water and Oil. Jurnal Teknologi

Keluaran Khas., pp. 425–442.

Muji, S.Z.M., Morsin, M., Abdul Rahim, R. (2009). Criteria for sensor selection in

optical tomography, IEEE Symposium on Industrial Electronics and

Applications (ISIEA 2009), Kuala Lumpur, Malaysia

Muji, S.Z.M, Abdul Rahim, R. (2010). Two Microcontrollers Interaction Using

C, Second International Conference on Computer Research & Development,

Page 290 – 292

Muji, S.Z.M (2012). Optical tomography for solid gas measurement using

mix Projection. Doctor Philosophy.UTM

Muji, S.Z.M, C.L. Goh, N.M.N. Ayob, Abdul Rahim, R. (2013). Optical tomography

hardware development for solid gas measurement using mixed projection.

Flow Measurement and Instrumentation. Volume 33, Pages 110–121

Muji, S.Z.M, Abdul Rahim, R., Rahiman,M.H.F. ,Zarina Tukiran,

Nor Muzakkir Nor Ayob, Mohamad, E.J., Muhammad Jaysuman

Puspanathan(2013). Optical tomography:Image improvement using mixed

projection of parallel and fan beam modes. Measurement. Volume

46(2013)1970–1978

Norpaiza M. Hasan, Barry J. Azzopardi(2007). Imaging stratifying liquid–liquid flow

by capacitance tomography. Flow Measurement and Instrumentation.

Volume 18, 241–246

Pang, J. F. (2004). Real Time Velocity and Mass Flow Rate Measurement using

Optical Tomography. Master Engineering. Universiti Teknologi Malaysia.

Pham M H, Hua Y and Gray N. B. (1999). Eddy current tomography for metal

solidification imaging. Proc. 1st World Congress on Industrial Process

Tomography, Buxton, UK, 14–17 April pp 451–8

Rahiman,M.H.F. , Abdul Rahim. R. and Zakaria, Z. (2008). Design and

modeling of Ultrasonic Tomography for Two-Component High-Acoustic

Impedance Mixture. Sensors and Actuators A. Vol 147. 409-414.

Rahiman,M.H.F(2005). Non-Invasive Imaging of Liquid/Gas Flow using Ultrasonic

Transmission-Mode Tomography.Master Engineering.Universiti Teknologi

Malaysia

Page 32: MOHD FADZLI B ABD SHAIB - eprints.utm.myeprints.utm.my/id/eprint/48742/25/MohdFadzliAbdMFKE2014.pdf · mengenalpasti kawasan tersumbat dan saiz, pelbagai meter aliran boleh didapati

117

Rasif,M.Z.(2009).The Development of a Dual Modality Tomography(DMT) System

using Optical and Capacitance Sensors for Solid/Gas Flow Measurement.

Master Engineering.Universiti Teknologi Malaysia.

Rzasa,M.R.(2009).The measuring method for tests of horizontal two-phase gas-

liquid flows, using optical and capacitance tomography. Nuclear Engineering

and Design.239 (4),699-707.

Schleicher,E., Da Silva, M.J., Thiele, S., Li, A. Wollrab,E. and Hampel, U.(2008).

Design of an optical tomograph for the investigation of single- and two-phase

pipe flows. Meas. Sci. Technol. 19.(09),1-14.

Dyakowski, Thomasz, Laurent F.C. Jeanmeure, Artur J. Jaworski(2000).

Applications of electrical tomography for gas–solids and liquid–solids flows

— a review. Powder Technology. 112,174–192

Minagawa, Taisuke, Peyman Zirak, Udo M. Weigel, Anna K. Kristoffersen, Nicolas

Mateos, Alejandra Valencia, and Turgut Durduran,(2012). Low-cost diffuse

optical tomography for the classroom, American Journal of Physics .Volume

80, Issue 10, pp. 876

Vedam, S. S., Keall, P. J., Kini, V. R., Mostafavi, H., Shukla, H. P. and Mohan,

R.(2003). Acquiring a Four-Dimensional Computed Tomography Dataset

Using an External Respiratory Signal. Physics Medicine and Biology. 48: 45–

62.

Williams, R.A., Beck, M.S., Green, R.G. (1995). Process Tomography: Principles,

Techniques and Applications. Butterworth-Heinemann, Oxford, U. K.

W Q Yang, T. A. York (1999).New AC-based capacitance tomography system.

Meas. Sci. Technol. 146, Issue 1

W Q Yang (2010). Design of electrical capacitance sensors. Meas. Sci. Technol.

Vol. 21, p. 042001.

Ze Liu, Min He, Han Liang Xiong.(2005).Simulation study of the sensing field in

electromagnetic tomography for two-phase flow measurement. Measurement

.Volume 16, Issues 2–3, Pages 199–204

Ze Liu, Wuliang Yin , Xiufang Sun(2009). Design of Electromagnetic Tomography

System based on Integrated Impedance Analyzer, I2MTC 2009, 5-7 May

2009

Zheng, Y, Qiang Liu, Yang Li, Nabil Gindy(2006). Investigation on

concentration distribution and mass flow rate measurement for gravity cute

conveyor by optical tomography system. Measurement. Volume 39, 643-654

Zheng, Y, Yang Lib, Liu, Q (2007). Measurement of mass flow rate of

Page 33: MOHD FADZLI B ABD SHAIB - eprints.utm.myeprints.utm.my/id/eprint/48742/25/MohdFadzliAbdMFKE2014.pdf · mengenalpasti kawasan tersumbat dan saiz, pelbagai meter aliran boleh didapati

118

particulate solids in gravity chute conveyor based on laser sensing array.

Optics & Laser Technology, 39, 298–305

Zheng, Y. and Liu, Q(2010). Review on certain key issues in indirect measurements

of the mass flow rate of solids in pneumatic conveying pipelines.

Measurement. 43(6), 727-734