generator prime power top power generating...

2
TOP POWER GENERATING SET Branches Sibu +6084-322 022 Kuching +6082-244 155 Bintulu +6086-331 720 Miri +6085-424 716 Kota Kinabalu +6088-218 811 Sandakan +6089-217 799 Tawau +6089-776 355 Lahad Datu +6089-886 355 Kuala Lumpur +603-7845 3366 Johor Bahru +6 07-364 5049 Muar +6 06-951 0386 Ipoh +6 05-282 6382 Penang +604-530 2417 Singapore +65-6353 3933 Brunei +673-223 3641 Powered by Engine Characteristics Unit construction system with individual cylinders. Advanced injection and combustion system. Worldwide proven: Over 3.0 million engines in service. Only a few service points for the engine. Powerful and compact, low weight. Benefits Space-saving and cost-effective installation thanks to integrated cooling system. Low maintenance requirements together with legendary durability. High quality combined with simple configuration. MODEL: TPD25A - TPD500 Generator Prime Power Generating Set Model TPD25A TPD35A TPD55A TPD42A TPD65A TPD55 TPD70 TPD80 TPD100 TPD125 TPD150 TPD200 TPD250 TPD300 TPD350 TPD400 [TPD450B] TPD500 380 - 415V 50Hz kVA 25 35 55 42 65 55 70 80 100 125 150 200 250 300 350 400 [450] 500 kW 20 28 44 34 52 44 56 64 80 100 120 160 200 240 280 320 [360] 400 Pansar Company Sdn Bhd (50977M) Wisma Pansar, 23-27 Jalan Bengkel P O Box 319, 96007 Sibu, Sarawak. T +6084-333 366 F +6084-314 555 E [email protected] W pansar.com.my Prime Power Ratings Prime power 100%, permissible average power output equal to or below 60%, no time limitation, plus 5% extra power for governing purposes.

Upload: lekhuong

Post on 12-Jul-2019

233 views

Category:

Documents


0 download

TRANSCRIPT

TOP POWER GENERATING SET

BranchesSi bu +6084-322 022 Kuching +6082-244 155 Bintulu +6086-331 720 Miri +6085-424 716 Kota Kinabalu +6088-218 811 Sandakan +6089-217 799 Tawau +6089-776 355 Lahad Datu +6089-886 355 Kuala Lumpur +603-7845 3366 J o h o r B a h r u + 6 0 7 - 3 6 4 5 0 4 9 M u a r + 6 0 6 - 9 5 1 0 3 8 6 I p o h + 6 0 5 - 2 8 2 6 3 8 2Penang +604-530 2417 Singapore +65-6353 3933 Brunei +673-223 3641

Powered by

Engine Characteristics• Unit construction system with individual cylinders.• Advanced injection and combustion system.• Worldwide proven: Over 3.0 million engines in service.• Only a few service points for the engine.• Powerful and compact, low weight.

Benefits• Space-saving and cost-effective installation thanks to integrated cooling system.• Low maintenance requirements together with legendary durability.• High quality combined with simple configuration.

MODEL: TPD25A - TPD500

Generator Prime Power

Generating Set Model

TPD25A

TPD35A

TPD55A

TPD42A

TPD65A

TPD55

TPD70

TPD80

TPD100

TPD125

TPD150

TPD200

TPD250

TPD300

TPD350

TPD400 [TPD450B]

TPD500

380 - 415V 50Hz

kVA

25

35

55

42

65

55

70

80

100

125

150

200

250

300

350

400 [450]

500

kW

20

28

44

34

52

44

56

64

80

100

120

160

200

240

280

320 [360]

400

Pansar Company Sdn Bhd (50977M)

Wisma Pansar, 23-27 Jalan BengkelP O Box 319, 96007 Sibu, Sarawak.T +6084-333 366 F +6084-314 555 E [email protected] W pansar.com.my

Prime Power RatingsPrime power 100%, permissible average power output equal to or below 60%, no time limitation, plus 5% extra power for governing purposes.

Technical Specifications

Pansar Company Sdn Bhd (50977M)

Wisma Pansar, 23-27 Jalan Bengkel, P O Box 319, 96007 Sibu, Sarawak.T +6084-333 366 F +6084-314 555

E [email protected] W pansar.com.my

70ModelPrime Power

MakerModel

DisplacementBore / StrokeCompression Ratio

Prime Power at Flywheel

Piston Speed

Engine Speed

Specific Fuel Consumption

BMEP

Speed droop (Static)

Max Step Load Acceptance, 1st StepCoolant VolumeCooling Flow RateCombustion Air FlowOil Sump CapacityLube Oil SpecificationExhaust Temp. at 25°C AmbientExhaust Gas Flow RateBatterySound Pressure 1 metre Away

Governor

Type

Control Quality

Maker

RatingInsulation ClassDrip ProofOverspeedExcitationAir FlowOverload CapacitySustained short-circuit CurrentWaveform IEC=THFEfficiency At 0.8pfTPD Dimensions (mm)

Dry Weight

11.8

Bosch, Mechanical

1500

102 / 1321:20.6

6.6

Motorpal, Mechanical

19.3

(Open) 1400

21208701410

4110

(Canopy) 2300

11002150

32

475016002400

2950(Canopy)

265011501700

1800(Open)

460014002400

2750(Canopy)

250011501700

1600(Open)

475016502900

4500(Canopy)

300014002000

2500(Open)

475016502900

4600(Canopy)

300014002000

2550(Open)

601020302950

6200(Canopy)

330014002220

3100(Open)

601020302950

6200(Canopy)

330014002220

3100(Open)

23509001410

1500(Open)

437013002350

2600(Canopy)

380 - 415 Volt, 50Hz, 4-Pole

1:19

Heinzmann, Mechanical4.0 - 5.0%

1500

1800Lx700Wx1120H (Open)

1100 (Open) / 2000 (Canopy)

2850Lx1200Wx1800H (Canopy)

11.8

8.5

4.04101 / 126

6.3

12V, 110

-

108 / 130

< 3 %300%, 20 Sec

1350(Open) / 2200 (Canopy)

380 - 415 Volt, 50Hz, 4-PoleClass H

IP21

SHUNT

1970Lx720Wx1240H (Open)4110Lx1100Wx2150H (Canopy)

2250

1 hour in 6 hours period at 110% rated load

6.5

API Service Grade CD

Radiator, Water-Cooled, Turbocharged

G2, in accordance to ISO8582

1:17.5

G2, in accordance to ISO8582

20

54

15.9

1:16.5132 / 145

7.26

24V, 143

G2

(AH)

(kVA)(kW)

(rpm)

(L)

(dBA)

(L)(mm)

(kW)

(m/s)50%

(bar)

100%(g/kWh) 75%

(m3/h)(m3/h)

(L)

(°C)

(rpm)

(m3/min)(%)

(%)LWH

(Kg)

(m3/h)

Engine

Generator Set

Alternator

25

3 Cyl.

20

DEUTZF3L912

ECP28-2L/4

88.11314700910

660

5.3

2.83

27.57.8

233 [3.9L/h]214 [5.4L/h]216 [7.2L/h]

-15651089

460256

90

TPD25A

35

4 Cyl.

28

DEUTZF4L912

87.916307001060

760

1:20100 / 120

6.0

377.9

232 [5.2L/h]214 [7.2L/h]217 [9.7L/h]

-181014411

455336

91

3.77

ECP32-2S/4

TPD35A

55

6 Cyl.

44

DEUTZF6L912

ECP32-2L/4

89.918207001020

950

100%

12V, 110

5.65

557.8

233 [7.8L/h]214 [10.8L/h]216 [14.5L/h]

-261021613.5

460509

93

TPD55A

42

4 Cyl.

34

DEUTZF4L914

ECP32-1L/4

88.816307001060

780

43.08.0

203 [5.3L/h]192 [7.5L/h]192 [10.0L/h]

-181017411

510476

92.5

4.31

TPD42A

65

6 Cyl.

52

DEUTZF6L914

ECP32-3L/4

90.418407001020

970

65.08.0

198 [7.8L/h]186 [11.0L/h]187 [14.7L/h]

-261026213.5

560715

92.7

6.47

TPD65A

55

4 Cyl.

44

DEUTZBF4M2012

ECP32-2L/4

89.9

5210.3

229 [7.4L/h]221 [10.7L/h]229 [14.2L/h]

15.95400216

566245

93

-

TPD55

4 Cyl.

56

DEUTZBF4M2012C

ECP32-3L/4

90.4

66.113.1

205 [8.7L/h]199 [12.7L/h]200 [17.0L/h]

17.94680268

540318

95.5

-

TPD70

80

4 Cyl.

64

DEUTZBF4M1013EC

ECP34-1S/4

91.2

96.117.1

212 [13.1L/h]211 [19.3L/h]214 [25.8L/h]

19.76100365.3

5601102

97

TPD80

100

4 Cyl.

80

DEUTZBF4M1013EC

ECP34-2S/4

91.9

11

4.76

96.117.1

212 [13.1L/h]211 [19.3L/h]214 [25.8L/h]

19.76100365.3

5601102

97

-

TPD100

150

6 Cyl.

120

DEUTZBF6M1013EC

ECP34-2L/4

92.9

138.115.5

202 [17.7L/h]199 [26.1L/h]198 [34.6L/h]

23.110800607

4801602

102

70%

Heinzmann

1500

4.0 - 5.0%

TPD150

200

6 Cyl.

160

DEUTZBF6M1013FC

ECO38-2SN/4

92.4

178.620.0

226 [24.5 L/h]222 [36.5L/h]226 [49.5L/h]

27.311160749

5602189

98

7.15

6.5

-

TPD200

125

4 Cyl.

100

DEUTZBF4M1013FC

ECP34-1L/4

92.4

12421.7

210 [15.7L/h]203 [23.5L/h]204 [32.2L/h]

19.79000482.1

5301389

101

EMR Electronic0 - 3.0%

12V, 143

1:18.1

6.5

-

TPD125

300

6 Cyl. V

240

DEUTZBF6M1015C

ECO38-2LN/4

93.4

301.220.2

203 [38.2L/h]203 [57.5L/h]208 [78.5L/h]

95.0209521340

545

101

65%

34

3640

TPD300

ECO38-3LN/4

350

6 Cyl. V

280

DEUTZBF6M1015CP

93.2

327.322.0

208 [42.0L/h]208 [63.1L/h]216 [87.5L/h]

98.0241201386

5453990

101

60%

34

TPD350

400 (450)

8 Cyl. V

320 (360)

DEUTZBF8M1015C

ECO40-1S/4

93.2 (93.4)

(ECO40-2S/4)

391.319.7

203 [48.8L/h]203 [73.3L/h]207 [99.6L/h]

102241202092

5104765

105

65%

45

TPD400

500

8 Cyl. V

400

DEUTZBF8M1015CP

ECO40-3S/4

93.6

433.921.9

210 [56.4L/h]211 [84.9L/h]221 [118.7L/h]

116331201848

5605377

105

45

60%

TPD500

380-415 Volt, 50Hz, 4-Pole

1 hour in 6 hours period at 110% rated load

Class HIP212250

SHUNT

< 2 %300%, 20 Sec

API Service Grade CD

G2, in accordance to ISO85825.0 - 6.0%

Air-Cooled, Natural Aspirated

MECC ALTE MECC ALTE

1 hour in 6 hours period at 110% rated load

Class HIP21

SHUNT2250

< 3 %300%, 20 Sec

0 - 3.0%EMR Electronic

Radiator, Water-Cooled, Turbocharged11.9

1500

API Service Grade CF

MECC ALTE

250

6 Cyl.

200

DEUTZTCD2013L64V

ECO38-1LN/4

93.1

238.428

229 [28.7L/h]213 [39.9L/h]200 [51.0L/h]

2716200909

5302547

97.6

G3

1:17

24

-

TPD250

Fuel calorific value is based on 42700 kJ/kg + 5 %, density 0.835 kg/dm3, temperature 280 K.Sound power values measured in accordance with ISO 6798.The heat quantities are valid for the dimensioning of the cooling system. They are given for the engine with the highest fuel consumption.All data are provided for informational purposes only and are subject to amendment.