vlp company profile

Upload: yusuf-mohd-salleh

Post on 06-Mar-2016

399 views

Category:

Documents


4 download

DESCRIPTION

spd leading company in malaysia

TRANSCRIPT

  • .

    (733984D)

    COMPANY PROFILE

    VLP ENGINEERING SDN BHD

    NO 30, JALAN PJU 10/10D

    SAUJANA DAMANSARA

    47830 PETALING JAYA

    SELANGOR DARUL EHSAN

    TEL: 603-6148 3304 FAX: 603-6148 3305

    EMAIL: [email protected]

    www.vlpengineering.com

  • CONTENTS

    Company Background

    Corporate Information

    Organization Chart

    Licenses And Registration

    Technical Specification

    Products and Specification

    Customer Purchase Order

    Current And Completed Project

  • COMPANY BACKGROUND

  • VLP Engineering Sdn Bhd was inaugurated on 18th May 2006 and office of the

    company is located at Saujana Damansara, Petaling Jaya, Selangor Darul Ehsan.

    We have several years of invaluable experience in specializing works related in

    the Lightning Protection System and Surge Protection System.

    VLP Engineering Sdn Bhd is a leading sole distributor and installer for the

    MARSA electrical device products. The product brand known as MARSA are

    manufactured locally whereby its factory is situated at Subang Bestari under

    the manufacturer of Transient Resources Sdn. Bhd. Besides being a sole

    distributor, VLP Engineering Sdn Bhd also provide other technical services

    namely design of Lightning Protection System (LPS), Electrical Project

    Management, Trouble Shooting in matters related to lightning surge.

    MARSA product have been in the market for more than six years and the

    products research and development (R&D) is being done continuously. The

    enhancement of such product has taken place for more than ten years. Since

    its inception, MARSA products have been undergone numerous testing and

    product development in order to fulfill the need and demand as requested by

    the prospective clients. MARSA product has been tested under the Malaysian

    extreme climatic conditions of 200 to 300 strikes of lightning per year. Thus,

    we anticipate and intended that MARSAs product is considered the best in

    Malaysia in term of reliability, functionalbility, durability and money worth

    buying, consequently the best product in the world.

    The research was done in collaboration with the TM Research and

    Development as well as SIRIM Research and Development respectively. All of

    MARSA products have been tested and approved by SIRIM according to the

    requirement standards and compliance to the MS IEC 61643-1 and MS IEC

    61643-12. Likewise, its also compliance to International Standards of IEEE

    C62.41 and BS 6651 for the Lightning and Surge Protection Device.

  • In order to be more competitive and consequently the leader in the Lightning

    Protection System as well as the Surge Protection System, the company are

    currently armed with experience and professional team whom are expert in

    their sales and marketing field as well as expertise in the technical aspect. The

    company always maintains a good relationship with its customer both are from

    the private and government sector.

    Our company had completed many projects in collaboration with government

    agency and also from the private sectors. List of clients of completed and

    current projects could be viewed in the current and completed projects.

    Periodically, our company always makes sure that the products that we

    distributed in the market have the best quality and are always compliance to

    the Malaysian standards. It is our practice that the product initially being test

    prior being installed at the site. Therefore, the R&D has never being end by the

    Research and Development Team at Transient Resources Sdn. Bhd.

    In conclusion, since we are equipped with the best team and also the best

    products, we are optimist and ready to take the local and global challenges in

    the pursuit of sales of Lightning and Surge protection system in Malaysia albeit

    with other brand in the market and we intend to export MARSA product to the

    International market in the near future.

  • OBJECTIVE

    Analyze and measure potential market demand for our product.

    Providing efficient delivery services to the customers.

    Advice and supply customer of the most suitable product without

    compromise the quality.

    Establishing customer loyalty and continues business relationship.

    Attaining the highest level of customer satisfaction.

    MISSION

    Our mission is to create awareness and educate everyone about the

    harmful and the impact that could cause by lightning and surge.

    Subsequently, we want to distribute MARSA products to Asian countries

    since those countries are experiencing similar lightning characteristics

    with our country. Moreover, we intend to create and design new surge

    protection devices in tandem with the advancement of science and

    technology. Thus, we want to ensure that our products have the best

    quality and could give the most satisfaction to our customers.

    VISION

    The companys vision is to be the first local company that distributes the

    electrical devices product that could be accepted and used by every

    country in this world. The product than are compliance not only with

    Malaysian and International standards, but also with other standards

    uses in other countries. We also aim to produce products that use the

    latest technology.

  • CORPORATE INFORMATION

  • CORPORATE INFORMATION

    Companys Name : VLP ENGINEERING SDN BHD

    Companys Address : No. 30, Jalan PJU 10/10D,

    Saujana Damansara,

    47830 Petaling Jaya,

    Selangor Darul Ehsan.

    Telephone No. : +603-6148 3304

    Fax No. : +603-6148 3305

    Email : [email protected]

    Website : www.vlpengineering.com

    Date Of Established : 18th May 2006

    Scope Of Registration : Supply and Installation for Electrical Product

    Registration No. : 733984 D

    Authorized Bank : Bumiputra Commerce Berhad

    Share Holder : Authorized Capital

    RM 100,000.00

    : Paid Up Capital

    RM 100,000.00

  • ORGANIZATION CHART

  • MANAGING DIRECTOR

    MOHD KHAIR B. SALLEH

    DIRECTOR

    MOHD KHAIRI BIN AZMI

    PROJECT DIVISION

    BUSINESS DIVISION

    ADMIN DIVISION

    SITE SUPERVISOR

    KAMARUL AKMAL FIRDAUS B.

    KAMARUDDIN

    YUSRI B. MOHAMAD YUSOF

    MOHD SYAFIQ BIN MOHD

    RAFFIE

    SITE STAFF / WORKERS

    SALES

    TECHNICAL

    REGIONAL SALES

    MANAGER

    JAMES OW

    BUSINESS

    DEVELOPMENT

    MANAGER

    ABD RAZAK B. HARON

    DR. RAZAK ZAINUDDIN

    TECHNICAL

    MANAGER

    SHAHARMAN B.

    HARON

    HUMAN

    RESORCES

    FINANCE

    ACCOUNT

    EXECUTIVE

    MOHAMMAD

    KAMAL B. ABDUL

    RAHMAN

    HEAD OF HR

    NOR AZURA BT

    ZAINAL

    SALES EXECUTIVE

    HEAD OF PROJECT DIVISION

    MOHD KHAIRI B. AZMI

    PROJECT COORDINATOR

    AHMAD AMZARI B. MOHD RAPIAI

    ENGINEER

    NUR AZIRA BT MOHD SALEH

    SHAKIRA FAAIZA BT MAZLAN

    MOHD HILMI BIN ABD MOKHTI

    ADMIN

    EXECUTIVE

    DRAUGHTMAN /

    TECHNICAL ASISSTANT

    MARKETING

    EXECUTIVE

  • LICENSES AND REGISTRATION

  • CUSTOMER PURCHASE ORDER

  • PRODUCT AND SPECIFICATION

  • PICTURE OF MARSA PRODUCTS

  • GENERAL SPECIFICATION

    The surge protection system shall be tested and confirm to the following codes of practice:

    Malaysian Standard MS IEC 61643-1 : 2004

    American Standard ANSI/IEEE C62.41 : 1991

    British Standard BS6651-1999, Annex C

    International Telecommunications Unions (formerly known as CCITT) ITU IX K17

    Surge protection device (SPD) for power line system shall provide phase to earth, phase to neutral and

    neutral to earth protection (L-E, L-N, N-E) with 7 module full mode protection monoblock type (Note:

    3+1 mode not accepted). Whereby phase to earth protection shall have the varistor connected direct

    between phase to earth and not through phase to neutral to earth.

    Surge protection device for data lines system shall provide transverse and common modes protection.

    During its operation the power lines SPD shall not interrupt the system (spark gap technology that

    connect between phase and neutral or earth and have large AC follow on currents when conducting will

    not be accepted).

    The data line SPD shall be compatible and transparent to the existing controller systems. During

    lightning surge condition the SPD shall not interrupt the operation of the system.

  • PRODUCT

    FEATURES AND BENEFITS

    PSP1 20240

    Category B & C, 60kA total protection, 20kA per phase.

    Withstand surge current 20kA per phase (L-N), (L-E), (N-E)

    Design for single phase power line. Suitable for Main Switch

    Board, Sub switch and Distribution Board with incoming cable

    35mm or less.

    PSP1 - 40240

    Category B & C, 120kA total protection, 40kA per phase.

    Withstand surge current 40kA per phase (L-N), (L-E), (N-E)

    Design for single phase power line. Suitable for main Switch

    Board, Sub Switch and Distribution Board, with incoming cable

    95mm or less.

    PSP1 20415

    Category B & C, 140kA total protection, 20kA per phase.

    Withstand surge current 20kA per phase (L-N), (L-E), (N-E)

    Design for three phase power line. Suitable for main Switch

    Board, Sub Switch and Distribution Board, with incoming cable

    35mm or less.

    Suitable for electrical, electronic and mechanical equipment (control

    system)

    PSP1 40415

    Category B & C, 280kA total protection, 40kA per phase.

    Withstand surge current 40kA per phase (L-N), (L-E), (N-E)

    Design for three phase power line. Suitable for main Switch

    Board, Sub Switch and Distribution Board, with incoming cable

    95mm or less.

    Suitable for electrical, electronic and mechanical equipment (control

    system)

  • PRODUCT

    FEATURES AND BENEFITS

    PSP1- 80415

    Category B & C, 560kA total protection, 80kA per phase.

    Withstand surge current 40kA per phase (L-N), (L-E), (N-E)

    Design for three phase power line. Suitable for main Switch Board, Sub

    Switch and Distribution Board, with incoming cable 95mm or more

    Suitable for electrical, electronic and mechanical equipment (control

    system)

    PLUG IN CAT A

    PROTECTOR

    (POSP-01)

    PISP 1 01. MARSA models featuring all mode protection for all combination of line

    (L-N, L-E, and N-E) that ensure the maximum level protection is achieve

    at all time.

    It designed for installation in any wiring system worldwide.

    The surge protectors are made of metal enclosures.

    High safety standard requirement.

    Use before the connection of power supply to the electrical appliance.

    PLUG IN CAT A

    PROTECTOR

    (POSP-03)

    PISP 1 03. MARSA models featuring all mode protection for all combination of line

    (L-N, L-E, and N-E) that ensure the maximum level protection is achieve

    at all time.

    It designed for installation in any wiring system worldwide.

    The surge protectors are made of metal enclosures.

    High safety standard requirement.

    Use before the connection of power supply to the electrical appliance.

    POWER LINE SURGE

    PROTECTOR 240V

    PLP1 240V. MARSA Power Line Protector is a protector for 240V AC power line

    equipment. It is a din rail mountable single pair surge protector module

    range for 240Vac in solid state protectors with various housing

    configurations.

    Provides a range of transient and operating performance characteristics

    to protect interface equipment from transient on the AC supply lines.

  • PRODUCT

    FEATURES AND BENEFITS

    COAXIAL CABLE

    SURGE PROTECTOR

    (CXP1103)

    It designed particularly to protect audio and video single line.

    Use for broadcasting equipment from being damaged by lightning over

    voltages and over current via coaxial cable.

    Use frequency range up to maximum 460MHz allow at -3dB.

    Limiting the transient voltage and clamping voltage.

    Low clamping voltage.

    KRONE (KP101 & KP110)

    Designed to divert the large surge away from the Subscriber Line

    Interface Circuit (SLIC).

    20MHz working frequency.

    Provide good condition.

    Easy maintenance and replaceable.

    SIGNAL & DATA LINE

    PROTECTOR

    (LC)

    DLP1-6/LC, DLP1-12/LC, DLP1-24/LC, DLP1-30/LC, DLP1-50/LC, DLP1-

    PSTN/LC, DLP1-180/LC.

    Provides for protection for data and signal interface equipment from

    effect of lightning surge.

    Protect all electrical and electronic equipment connected through signal

    and data cables.

    Efficiency clamps the surge voltages with minimal distortion.

    Featuring multistage transient protection.

    Best suit for low current protection.

    Completed with indicator (optional).

    SIGNAL & DATA LINE

    PROTECTOR

    (SC)

    DLP1-6/SC, DLP1-12/SC, DLP1-24/SC, DLP1-30/SC, DLP1-50/SC, DLP1-

    PSTN/SC, DLP1-180/SC.

    Provides for protection for data and signal interface equipment from

    effect of lightning surge.

    Protect all electrical and electronic equipment connected through signal

    and data cables.

    Efficiency clamps the surge voltages with minimal distortion.

    Featuring multistage transient protection.

    Best suit for low current protection.

    Completed with indicator (optional).

  • CURRENT AND COMPLETED PROJECT

  • Current Projects

    Bil Project Name

    1. FILEM NASIONAL MALAYSIA (FINAS) 2. KOLEJ KEDIAMAN UITM SG. BULOH, SELANGOR 3. HUKM, CHERAS, WILAYAH PERSEKUTUAN 4. KELANA JAYA LINE (PRASARANA), KELANA JAYA 5. KOMPLEKS PERMATA, UKM 6. PETRONAS PETROL PUMP 7. MURPHY OIL, BINTULU 8. IIUM, KUANTAN

    Completed Projects

    Bil Project Name

    1. MAHA PROJECT 2008 (PHASE I) 2. PERUMAHAN & PANGSAPURI CHERAS 3. UNIVERSITI DARUL IMAN 4. FAKULTI KEJURURAWATAN KUBANG KERIAN, KELANTAN 5. KNOWLEDGE WORKERS DEVELOPMENT INSTITUTE (KWDI), CYBERJAYA 6. INSTITUT KEMAHIRAN BAITULMAL (IKB), MAIWP, KUALA LUMPUR 7. PUSAT PENGAJIAN PASCASISWAZAH UNIVERSITI KEBANGSAAN MALAYSIA (UKM) 8. KOMPLEKS MAHKAMAH SYARIAH, JALAN DUTA 9. UNIVERSITI PENDIDIKAN SULTAN IDRIS (UPSI)

    10. UNIVERSITI MALAYSIA SABAH (UMS) 11. PERUMAHAN KAJANG, SELANGOR 12. ISTANA MELAWATI, PUTRAJAYA 13. POLITEKNIK MERSING, JOHOR 14. KOLEJ INSANIAH (KUIN), KEDAH 15. EMPANGAN BERIS (JPS), KEDAH 16. INSTITUT KEMAHIRAN MALAYSIA (IKM) MUAR, JOHOR

    17. LAPANGAN TERBANG SULTAN ZAINAL ABIDIN, TERENGGANU 18. STADIUM BOLA SEPAK, TERENGGANU 19. LANGKAWI CABLE CAR 20. PUSAT PERBADANAN PUTRAJAYA 21. BUNGALOW DR. ASHAR, BANGI 22. PERUMAHAN KAJANG, SELANGOR 23. MEDIAHOUSE, MELAKA 24. ISTANA SULTAN PAHANG, PAHANG 25. KKTM,REMBAU 26. LOT BUNGALOW KEM WARDIEBURN,KUALA LUMPUR 27. LOT BUNGALOW, CEMERLANG HEIGHTS 28. PORT SWEETENHAM 29. SHAH ALAM THEATRE 30. POLICE STATION, BAYAN BARU 31. SEA SURVEILLANCE SYSTEM (PHASE II), SABAH 32. KEDIAMAN PERDANA MENTERI, PUTRAJAYA 33. PUSAT TENAGA ATOM (AELB), DENGKIL 33. MAKMAL KESIHATAN KEBANGSAAN 34. HOSPITAL UNIVERSITI MALAYA

    35. HOSPITAL PUTRAJAYA 36. JABATAN PERDANA MENTERI (JPM)

  • INSTALLATION OF SURGE PROTECTOR DEVICE (SPD) AT SULTAN ZAINAL

    ABIDIN TERENGGANU AIRPORT

    INSTALLATION OF LIGHTNING PROTECTION SYSTEM (LPS) AT UNIVERSITI

    PENDIDIKAN SULTAN IDRIS (UPSI)

  • INSTALLATION OF LIGHTNING PROTECTION SYSTEM (LPS) AT PUSAT

    PENGAJIAN SISWAZAH UNIVERSITI KEBANGSAAN MALAYSIA (UKM)

    INSTALLATION OF LIGHTNING PROTECTION SYSTEM (LPS) AT KNOWLEDGE

    WORKERS DEVELOPMENT INSTITUTE (KWDI) CYBERJAYA

  • CABLE CAR LANGKAWI

    ISTANA PAHANG

    KEM WARDIEBURN, KUALA LUMPUR

  • MAHA, SERDANG (FASA 2)

    BUNGALOW, CEMERLANG HEIGHT

    MAHA, SERDANG (FASA 1)

  • RUMAH TERES BANDAR BARU BANGI

    MEDIA HOUSE, MELAKA

    TENAGA ATOM (AELB) DENGKIL

  • TEATER, SHAH ALAM

    SEA SURVEILLANCE SYSTEM, SABAH

    KEDIAMAN RASMI PERDANA MENTERI

  • LIGHTNING (FARADAY CAGE) & SURGE PROTECTION SYSTEM AT SULTAN MAHMUD KUALA

    TERENGGANU TERMINAL BUILDING PACKAGE 2

    LIGHTNING (FARADAY CAGE) & SURGE PROTECTION SYSTEM AT KNOWLEDGE WORKERS

    DEVELOPMENT INSTITUTE (PHASE 2)

  • LIGHTNING PROTECTION SYSTEM (FARADAY CAGE) AT KOMPLEKS MAHAKAMAH SYARIAH

    WILAYAH PERSEKUTUAN, JALAN DUTA, KUALA LUMPUR

    LIGHTNING PROTECTION SYSTEM (FARADAY CAGE) AT KOLEJ UNIVERSITI INSANIAH

    (KUIN), KUALA KETIL, MUKIM TAWAR, DAERAH BALING, KEDAH DARUL AMAN

  • LIGHTNING PROTECTION SYSTEM (FARADAY CAGE) AT POLITEKNIK MERSING, DAERAH

    MERSING, JOHOR DARUL TAKZIM FOR MINISTRY OF EDUCATIONAL

    LIGHTNING PROTECTION SYSTEM (FARADAY CAGE) AT KOMPLEKS PENYELIDIKAN (IMEN),

    JALAN TUN ISMAIL, UNIVERSITI KEBANGSAAN MALAYSIA

  • LIGHTNING PROTECTION SYSTEM (FARADAY CAGE) AT UNIVERSITI PENDIDIKAN SULTAN

    IDRIS (UPSI) TANJUNG MALIM, PERAK DARUL RIDZUAN

    LIGHTNING PROTECTION SYSTEM (FARADAY CAGE) AT UNIVERSITI KEBANGSAAN

    MALAYSIA (UKM) PUSAT PENGAJIAN SISWAZAH & PUSAT PELAJAR ANTARABANGSA

  • LIGHTNING PROTECTION SYSTEM (FARADAY CAGE) AT KLINIK PERGIGIAN DAN KOLEJ

    KEDIAMAN UNIVERSITI TEKNOLOGI MARA (UITM) SUNGAI BULOH, MUKIM BATU, DAERAH

    GOMBAK, SELANGOR DARUL EHSAN

    LIGHTNING PROTECTION SYSTEM (FARADAY CAGE) AT PRA KLINIKAL FAKULTI PERUBATAN

    UNIVERSITI KEBANGSAAN MALAYSIA, JALAN YAACOB LATIF, BANDAR TUN RAZAK, MUKIM

    KUALA LUMPUR, CHERAS, KUALA LUMPUR

  • BINTULU ONSHORE RECEIVING FACILITY (BORF) - EARTHING, LIGHTNING AND SURGE

    PROTECTION SYSTEM

    A. AGGREKO & SCADA MARSHALLING PANEL

    Figure 1: Installation of PSP1-40240 for incoming power

    Figure 2: Installation of POSP1-03 and POSP1-01 at first, second and fourth power outlet socket

  • Figure 3: Installation of POSP1-03 at fifth Figure 4: Installation of POSP1-03 at sixth power outlet socket power outlet socket

    Figure 5: Installation of POSP1-03 at seventh power outlet socket

    Figure 6: Installation of RJ45 at LAN line from Murphy

  • B. AIR COMPRESSOR

    Figure 1: Installation of PLP1-240 and DLP1-30/LC at air compressor A (MGP1-UCP-5410A)

    Figure 2: Installation of PLP1-240 and DLP1-30/LC at air compressor B (MGP1-UCP-5410B)

  • C. CCTV

    Figure 1: Installation of PLP1-240, DLP1-12/LC and CXP1-103 at board MGP1-TJB-CCTV-001

    Figure 2: Installation of PLP1-240, DLP1-12/LC and CXP1-103 at board MGP1-TJB-CCTV-002

    Figure 3: Installation of PLP1-240, DLP1-12/LC and CXP1-103 at board MGP1-TJB-CCTV-003

  • SUPPLY, DELIVER, INSTALL, TEST AND COMMISIONING OF LIGHTNING PROTECTION SYSTEM

    FOR CONTROL CENTRE EQUIPMENT ROOM, KELANA JAYA LINE

  • SUPPLY, DELIVER, INSTALL, TEST AND COMMISIONING OF LIGHTNING PROTECTION SYSTEM

    FOR CONTROL CENTRE EQUIPMENT ROOM, KELANA JAYA LINE

    Installation of surge protectors c/w metal clad junction box at

    Point af Entry to EER for roof top CCTV and GPS feeds

    Surge Protectors Surge Protectors for GPS feeds

    For Roof Top CCTV

    Installation of SPDs for GPS units to RSU in EER.

    Installation of SPD for CCTV no:904

  • SUPPLY, DELIVER, INSTALL, TEST AND COMMISIONING OF LIGHTNING PROTECTION SYSTEM

    FOR CONTROL CENTRE EQUIPMENT ROOM, KELANA JAYA LINE

    POWER SPD FOR DB CCTV POWER SPD FOR DB FEEDER RAD

    POWER SPDs FOR DB EER/3 POWER SPDs FOR DB EER/1 & ISOLATION

    & ISOLATION TRANSFORMER 2 TRANSFORMER 1

  • Sole Distributor Power Surge Protector :

    VVLLPP EENNGGIINNEEEERRIINNGG SSDDNN BBHHDD

    NNoo.. 3300,, JJaallaann PPJJUU 1100//1100DD,,

    SSaauujjaannaa DDaammaannssaarraa,,

    4477883300 PPeettaalliinngg JJaayyaa,,

    SSeellaannggoorr DDaarruull EEhhssaann

    TTeell:: 0033--66114488 33330044

    FFaaxx:: 0033--66114488 33330055

    EE--mmaaiill:: vvllppeennggiinneeeerriinngg@@yyaahhoooo..ccoomm

    WWeebbssiittee:: wwwwww..vvllppeennggiinneeeerriinngg..ccoomm