quality endorsement

14

Upload: syerifaizal-hj-mustapha

Post on 18-Dec-2015

39 views

Category:

Documents


0 download

DESCRIPTION

Quality Endorsement

TRANSCRIPT

  • SPEC

    IMEN

    COPY

    SPEC

    IMEN

    COPY

  • sTlnrrr Prnutllllt tIlnr BInilt0Tingkat 10, Bangunan MAS [44205'M]Jalan Sultan lsmeil50250 Kuala Lumpurtel (603) 2052 3838 faks (603) 2164 8451E-mail : [email protected]

    RUJUKAN KAMITARIKH

    : sPNBrr&P/PEM(04)lSUP379l07 I t01 26 JU|-AI 2010

    KCC PAINTS SDN. BHD.LOT 13, JALAN ANGGERIK MOKARA 3rls4SEKSYEN 3140460 KOTA KEMUNING, SHAH ALAMSELANGOR

    Tuan / Puan,MENGEMASKINI STATUS PENDAFTARAN SEBAGAI PANEL PEMBEKAL IPERKHIDMATAN DI SYARIKAT PERUMAHAN NEGARA BERHAD (SPNB)

    Dengan segala hormatnya kami merujuk kepada perkara di atas.

    Sukacita dimaklumkan bahawa pihak kami telah mengemaskn profal terkini firma /syarkat tuan / puan ke dalam Sistem Pengkalan Dat pendaftaran sebaga panel SPNB.Berikut adalah maklumat berkaitan mengemaskini pendaftaran tersebut untuk makluman danrujukan tuan :

    PENGKHUSUSAN PENDAFTARANI.D. PENDAFTARAN

    PEMBEKALsuP 379133

    Untuk makluman tuan, sebarang pemberian kerja oleh SPNB adalah teftakluk kepada syarat-syarat dan peraturan yang telah ditetapkan oleh Kementeran Kewangan Malaysia danpengurusan SPNB.

    Sehubungan dengan itu, pihak SPNB akan menghubungi syarikat / firma tuan sekiranyaterdapat keperluan untuk mendapatkan apa-apa perkhidmatan yang bersesuaian denganpengkhususan bidang pendaftaran syarikat / firma tuan.Sekian, terima kasih.

    Yang benar,SYARIKAT PERUMAHAN NEGARA BERHAD

    HISHAtg,B.AHMAD fi?Pengur BesarJabatan Perolehan\\Crussol9t\cru d6umotslsa Folds\2oOU(EiASKINf PANEL NOV 20@-20lSUR-AT PEMBERITAHUAN KEMASKINNEMBEXj,L\KEMASKINI 0E d

    rrr,r, o,*r,, Q,(r, nft. @"rn rrn

  • 1.0

    2.0

    5.0

    6.0

    3.0

    4.0

    SYARAT-SYARAT KELULUSAN PENDAFTARAN SEBAGAI PANEL KONTRAKTOR/PERUNDING/PEMBEKAL & PERKHIDMATAN/PEGUAMCARA

    SYARAT-SYARATl.l Kelulusan ini diberi berdasarkan maklumat-maklumat yang telah disampaikan oleh syarikat / firma tuan.1.2 Sebarang perubahan ke atas maklumat-maklumat tersebut hendaklah dimaklumkan kepada Syarikat

    Perumahan Negara Berhad (SPNB) dalam masa dua puluh satu (21) hari dari tarikh perubahan tersebutberlaku.

    1.3 Syarikat / firma hendaklah mengemukakan segala maklumat dalam tempoh yang ditetapkan apabiladiminta oleh SPNB. Kegagalan membuat demikian akan mengakibatkan tindakan seperti L5 di bawah.

    1.4 Syarikat / firmahendaklah memastikan bahawa bidang yang telah didaftar dalam sijil ini tidak bertindakdengan bidang yang telah diluluskan ke atas mana-mana syarikat seperti berikut.1.4.1 Mempunyai pemilik atau Ahli Lembaga Pengarah yang sama;atau1.4.2 Beroperasi di premis yang sama

    1.5 SPNB berhak membatalkan / menggantungkan pendaftaran syarikat I luma tuan tanpa apa-apa notis jikadidapati maklumat yang diberi tidak benar.

    PENGGANTUNGAN i PEMBATALAN PENDAFTARAN / TINDAKAN TATATERTIB2.1 Pendaftaran akan digantung / dibatalkan atau dikenakan tindakan tatatertib sekiranya didapati:

    2.1.1 Syarikat / Firma / Pemilik / Ahli Kongsi i Pengarah terlibat dalam sebarang kegiatan haramjenayah yang disabitkan dan didapati bersalah oleh Mahkamah di Malaysia atau di luar negeri.

    2.1.2 Sekiranya syarikat / firma menarik balik tawaran sebelum tender dipertimbangkan atau menolaktawaran setelah tawaran dibuat.

    2.1.3 Kegagalan syarikat I firma melaksanakan kontrak-kontrak yang telah ditandatangani denganSPNB.

    2.1.4 Meminda sijil perakuan ini dengan tujuan menipu atau lain-lain maksud.2.1.5 Membenarkan sijil perakuan ini disalahgunakan oleh syarikat / firma lain.2.1.6 Syarikat / frima didapati membuat pakatan harga dengan syarikat-syarikat lain semasa memasuki

    tender / sebut harga SPNB.

    TEMPOH PENDAFTARAN3.1 Pendaftaran hanya diperakui untuk tempoh sepertimana yanglrtera pada tarikh tamat perakuan di sijil

    perakuan ini

    PEMBAHARUAN / KEMASKINI4.1 Syarikat / ftrma tuan hendaklah membuat permohonan pembaharuan pendaftaran tiga (3) bulan sebelum

    tamat tempoh perakuan pendaftaran.4.2 Permohanan yang diterima selepas tamat tempoh pendaftaran adalah dianggap sebagai pendaftaran baru.4.3 Syarikat I firma tuan juga hendaklah mengemukakan profrl terkini setiap akhir tahun untuk tujuan

    kemaskini maklumat syarikat / hrma di dalam system pendaftaran SPNB.

    PENYERTAAN TENDER / SEBUT HARGA5.1 Sijil perakuan ini hendaklah ditunjukkan semasa mengambil dokumen tender sebutharga di dalam kepala /

    sub kepala (bidang) yang diluluskan sahaja.5.2 Salinan sijil perakuan ini hendaklah dikemukakan bersama-sama dokumen tender / sebutharga.

    HAK SYARIKAT PERUMAHAN NEGARA BERHAD6.1 SPNB berhak mendapatkan semula sijil perakuan ini apabila syarilat digantung / dibatalkan pendaftaran /

    dikenakan tindakan tatatenib.6.2 SPNB juga berhak untuk mendapatkan semula sijil perakuan ini pada bila-bila masa apabila dikehendaki

    SYARIKAT PERUMAHAN NEGARA BERHAD MEMBATALKAN ATAU MENGGANTUNGKAN PENDAFTARAN SYARIKATSEBAGAI PANEL KONTRAKTOR / PERUNDING / PEMBEKAL & PERKHIDMATAN / PEGUAMCARA

    TANPA APA-APA NOTIS JIKA DIDAPATI MAKLUMAT YANG DIBERI TIDAK BENARATAU GAGAL MENGEMUKAKAN MAKLUMAT SEPERTT YANG DIKEHENDAKI.

  • KCC PAINTS SDN BHDLOT 13, JALAN ANGGERIK MOKARA 31/54SEKSYEN 31 KOTA KEMUNING40460 SHAH AI-AM

    U/P: EN. MOHD ROSLAN SAMSURINORHPOR

    Tuan,

    Pcr: PENDAFTARAN SYARIKAT DI NMB

    I\4erujuk perkara di atas, sukacita tlimaklumkan bahawa pcrmohonan tuan untuk mcndaftarkanSyarikat tuan dengan NMB telah diluluskan berkuatkuasa mulai 07 Sept, 2005. Syarikat tuantclah disenaraikan dalam senarai pendaftaran kontraktor sebagai kontraktorbekalan/perkhidmatan. Bidang kerja yang terlibar adalah seperri berikut:

    A. KONTRAKTORBEKALAN/PERKHIDMATANMEMBEKAL CAT PENANDA JALAN "ROADLINE PAINT'' DAN"ROAD KERB''MEMBEKAL CAT UNTUK BANGUNANMEMBEKAL DAN MELAKSANA KERIA.KERIA MENGBCATPENANDA JALAN "ROADLINE PAINT'' DAN ROAD KBRB'"

    Tuan adalah dinasihatkan supaya memaklumkan kepada kami dari masr ke semasa sekiranyaterdapat sebarang perubahan keupayaan, struktur milikan, Lembaga Pengarah dan sebagainya.

    Dengan ini Syarikat tuan adalah layak menyertai sebarang tendcr yang diiklankan/dipelawa olehNMB dari semasa ke semasa atau melalui sebutharga yang akan kami edarkan,

    Kami mengucapkan terima kasih di atas minat tuan untuk memberikan perkhidmatan dan kamiyakin Syarikat tuan akan diberikan pertirnbangan yang sewajarnya di dalam penyertaan tendr:r/sebutharga kami kelak.

    Sekian, terima kasih.

    Ru.jukan

    Tarikh

    Yang benar,NORTHPORT (MALAY

    AN IBRAHIM

    cszU02.03tot-(tsze)0 6 OcT 2005

    Jalan Pelabuhan, Pelabuhan UlaG,42000 Port KlangP O Box 234,42009 Port KlangSelangor Darul Ehsan Malaysia

    oRtlrProtf Im L Y3tll !t{D(1468s0-A)

    Tel:603-3169 8888Fax: 603-31 69 88'l IFax:603-3169 8088

    www norlhport.com my

    {{.1

    1lJ t'lJ ": '1I *T'*

    I)3.

    00rb/p. Pcngurus Pcntadbiran

    BHD

    Certilicate No.404U9/

  • PROJECT

    OWNER

    MAIN CONTRACTOR

    PAINTING APPLICATOR

    WARRANTY PERIOD

    EFFECTIVE DATE

    EXPIRY DATE

    COATING SYSTEM

    SUBSTRATE

    TopcoatSealer/Primer Finishing

    ARCHITECT

    COLOUR

    5

    .................................................

    Performance Warranty

    Ref No. : PER13080001

    The Paint Specialist

    (323967-T)No. 1, Jalan Anggerik Mokara 31/55, Seksyen 31, Kota Kemuning, 40460 Shah Alam, Selangor D.E, Malaysia. Tel: 03 - 5122 2900 Fax: 03 - 5122 1900

    Cadangan Pembangunan, Perumahan, Perniagaan Dan Kemudahan Yang Mengand-ungi (FASA 1C2:- 2TRTB - Rumah Teres Jenis B; 2TRTC - Rumah Teres Jenis C; Pencawang Elektrik Di Atas Lot 967 (GRN 54284) Mukim Beranan, Daerah Hulu Langat, Selangor Darul Ehsan Untuk Tetuan Pelangi Semenyih Sdn. Bhd.

    Pelangi Semenyih Sdn. Bhd.

    Akitek Daya Sdn. Bhd.

    Lim Wee Ngeh Painting, Construction Sdn. Bhd

    HYK Bina Sdn. Bhd.

    5 Years

    01 / 03 / 2013

    28 / 02 / 2018

    Exterior Wall Finish

    Korevon 2565, Supro Korever K15004 & K12662

    Wall Sealer 100 Korevon 2565 Supro KoreverK15004 & K12662

    LIM WAI BINGeneral Manager

    SAMPLE

  • 1.WARRANTY

    KCC Paints Sdn.Bhd. (hereinafter called KCC) as Paint supplier, undertakes the full responsibility as supply and apply specialist applicator,hereby warranty that for a period of five (5) years, the paint system as recommended and applied for the project stated oveleat, would not be affected by the following defects: -

    Peeling / FlakingThis condition is manifested when the paint film peels away or detaches from the substrate.

    Cracking This condition is manifested by any visible cracking on the paint film other than that caused by plastering cracks.

    Fungus / Algae GrowthThis condition is established when there is growth of microorganisms from within the paint film that results in the marring of the appearance of the paint film through discoloration. Dirt stains which can be washed off by water- jetting and light scuffing is not considered as fungus / algaeinfestation.

    1.1 Allowance must be made for natural and gradual degradation of paint through effuxion of time. Claims on the warranty willbe subjected to such pro-rate base on elapse of time.within first 2 years _____________100% Cost of rectification covered.2 to 3 years _____________ 80% Cost of rectification covered.3 to 4 years _____________ 60% Cost of rectification covered.4 to 5 years _____________ 40% Cost of rectification covered.

    1.2 This warranty covers only rectification of coating failures / defects up to maximum of 100% of cost of surface preparation andpainting to moke good the defects only. Claims for incidental or consequential damages resulting from breach of the warrantyare specially excluded.

    2.0 EXCLUSION OF PERFORMANCE WARRANTY

    2.1 The warranty shall not cover defects caused directly or indirectly by any one or more of the factors defined below. Such defects will not qualify for claims under the warranty and shall be deemed invalid claims. 2.1.1 Efflorescence, deposit of soluble salts (from within plastering) upon drying, as result of plaster cracks of structural cracks

    are excluded.2.1.2 Specific areas where proper surface preparation methods as listed below on schedule I are not met and subject to prior

    written warning letter of non-compliance submited by KCC of which the matter was overruled.2.1.3 Damage of the coated surface caused by vandalism or by heavy impact , fire ,natural calamities, Act of God or

    normal wear and tear. 2.1.4 Deterioration of paint including but not limited to staining, efflorescence, fungus growth caused from constant

    dampness around and within the walls from air condition, high moisture retention caused from water ponding, seepageor defects of similar nature or inadequate or improper surface preparation.

    2.1.5 Uniform or even colour change.2.1.6 Surface deposition of fungus, dirt or any contaminant that can be removed through periodic cleaning. Fungus and

    algae growth that can be washed off is classified as a foreign layer deposited on the paint film. 2.1.7 Defects arising from work (alteration/extension) carried out onto the so affected areas of the building without the prior

    written agreement of KCC Paints. 2.1.8 Staining or discoloration caused from polluted atmosphere, undetected water or moisture from within the substrate, or

    from window screens, metal gutters, spout pipes, water down-pipes, etc. 2.1.9 Trace difference in colour or texture on new materials being supplied for repair work against previous material.

    2.2 This warranty will not be valid unless all outstanding sums of monies due to us has been paid and settled in full by the contractual parties.

    2.3 This warranty is explicitly issued to the client mentioned on front page for the project and the warranty cannot be assigned,transferred or charged in any manner to any other parties.

    3.0 PROCEDURES FOR CLAIMS3.1 Any defects claims should be made in writing and delivered by post or by hand to the Marketing Department, KCC Paints Sdn.

    Bhd. (323967-T ) No.1, Jalan Anggerik Mokara 31/ 55, Seksyen 31, Kota Kemuning, 40460 Shah Alam, Selangor Darul Ehsan. 3.2 A technical team will be despatched to evaluate the nature of the claim. Should their findings conclude the defects as within

    the scope of warranty as defined under WARRANTY, then KCC Paints Sdn. Bhd. shall supply the necessary paint materialsand labour to make good defects.

    3.3 Should our technical team conclude that the defects falls under the Exclusion Of Performance Warranty or other factors aliento the scope of warranty, then KCC Paints Sdn. Bhd. will not be held responsible for the claim and therefore, the claim shallbe deemed as invalid.

    3.4 Should client disagree with the conclusion of the technical evaluation pertaining to the defects, in particular under 3.3 thenan independent third party competent in such technical evaluation will be appointed to investigate. The appointment must seek prior mutual agreement between client and KCC Paints Sdn. Bhd. Their findings may be treated as conclusive, or the procedure may be repeated until a satisfactory conclusion can bemutually accepted between client and KCC Paints Sdn Bhd.

    3.5 Any Third party costs, in particular under clause 3.4, will be shared equally between client and KCC Paints Sdn. Bhd.

    4.0 PERIODIC CLEANINGPeriodic cleaning of the exterior surface is essential to maintain the aesthetic and durability of the coating system. Atmosphericdirt in the air can accumulate on flat areas like top of parapet, edges and ledges and with presence of rainwater, unsightly streak marks may be visible on light colours. Over passage of time, the accumulation of dirt and organic matter together withhigh moisture can promote the growth of algae although the paint can still be intact. The frequency of cleaning should preferably be least 12 (twelve) months interval depending environmental condition.

    5.0 SCHEDULE 1 (The Proposed System) Surface Preparation

    5.3 All new concrete plaster/masonry must be allowed dry out completely for at least 28 days.

    5.5 Apply one (1) coat of Supro wall sealer 100 follow by two (2) coats of Korevon & Supro Korever Exterior Acrylic paint.

    Our recommendation are as follows:a. Wash away loose dirt, dust and other contaminants with mild detergent ( 3 % to 5% dilution ) or clean water. b. Apply KCC Fungicidal Wash and allow to stand overnight.c. Clean away the fungicidal wash with clean water.

    5.1 Make good minor defects with suitable exterior grade Filler.5.2 Use Selleys No More Gaps to fill up all hairline cracks, gaps between window frames and walls, etc.

    5.4 Previously painted surfaces:- All areas affected by mould, lichen algae and moss are to be treated with KCC Fungicidal Wash. - Remove all loose or defective paint or powdery residues by thorough brushing and scraping, using a high pressure water jet.

    SAMPLE

  • PROJECT

    OWNER

    MAIN CONTRACTOR

    PAINTING APPLICATOR

    WARRANTY PERIOD

    EFFECTIVE DATE

    EXPIRY DATE

    COATING SYSTEM

    SUBSTRATE

    TopcoatSealer/Primer Finishing

    ARCHITECT

    COLOUR

    5

    .................................................

    (323967-T)No. 1, Jalan Anggerik Mokara 31/55, Seksyen 31, Kota Kemuning, 40460 Shah Alam, Selangor D.E, Malaysia. Tel: 03 - 5122 2900 Fax: 03 - 5122 1900

    Cadangan Pembangunan, Perumahan, Perniagaan Dan Kemudahan Yang Mengand-ungi (FASA 1C2:- 2TRTB - Rumah Teres Jenis B; 2TRTC - Rumah Teres Jenis C; Pencawang Elektrik Di Atas Lot 967 (GRN 54284) Mukim Beranan, Daerah Hulu Langat, Selangor Darul Ehsan Untuk Tetuan Pelangi Semenyih Sdn. Bhd.

    Pelangi Semenyih Sdn. Bhd.

    Akitek Daya Sdn. Bhd.

    Lim Wee Ngeh Painting, Construction Sdn. Bhd

    HYK Bina Sdn. Bhd.

    5 Years

    01 / 03 / 2013

    28 / 02 / 2018

    Exterior Wall Finish

    Korevon 2565, Supro Korever K15004 & K12662

    Wall Sealer 100 Korevon 2565 Supro KoreverK15004 & K12662

    Product Warranty

    Ref No. : PRO13080001

    The Paint Specialist

    LIM WAI BINGeneral Manager

    SAMPLE

  • 1.WARRANTY

    KCC Paints Sdn.Bhd. (hereinafter called KCC) as Paint supplier, warrants that all paints supplied for this project are of superior quality,within workable shelf life and contorms to strict in-house Quality Control Tests.KCC jointly warrants with your appointed paint applicator, that for a period of five (5) years , the paint system and surface preparationmethods as recommended and listed on schedule would not be affected by the following defects: -

    Peeling / FlakingThis condition is manifested when the paint film peels away or detaches from the substrate.

    Cracking This condition is manifested by any visible cracking on the paint film other than that caused by plastering cracks.

    Fungus / Algae GrowthThis condition is established when there is growth of microorganisms from within the paint film that results in the marring of the appearance of the paint film through discoloration. Dirt stains which can be washed off by water- jetting and light scuffing is not considered as fungus / algaeinfestation.

    1.1 Allowance must be made for gradual degradation of paint film from normal wear through the effluxion of time. Claims on the warranty will be subjected to such pro-rate of graduated wear based on the elapse of time.

    1.2 This warranty and liability is expressly limited to replacement of paint materials should it be proven that the material supplied to be defective. Claims for incidental or consequential damages resulting from a breach of this warranty are specifically excluded.

    2.2 This warranty will not be valid unless all outstanding sums of monies due to us has been paid and settled in full by the contractual parties.

    2.3 This warranty is explicitly issued to the client mentioned on front page for the project and the warranty cannot be assigned,transferred or charged in any manner to any other parties.

    3.0 PROCEDURES FOR CLAIMS

    3.1 Any defects claims should be made in writing and delivered by post or by hand to the Marketing Department, KCC Paints Sdn. Bhd. (323967-T ) No.1, Jalan Anggerik Mokara 31/ 55, Seksyen 31, Kota Kemuning, 40460 Shah Alam, Selangor Darul Ehsan.

    3.2 A technical team will be despatched to evaluate the nature of the claim. Should their findings conclude the defects as within the scope of warranty as defined under WARRANTY, then KCC Paints Sdn. Bhd. shall supply the necessary paint materials to make good such defects. At all times, this warranty is limited to replacement of paint materials only.

    3.3 Should our technical team conclude that the defects falls under the Exclusion Of Product Warranty or other factors alien to the scope of warranty, then KCC Paints Sdn. Bhd. will not be held responsible for the claim and therefore, the claim shall be deemed as invalid.

    3.4 Should client disagree with the conclusion of the technical evaluation pertaining to the defects, in particular under 3.3 thenan independent third party competent in such technical evaluation will be appointed to investigate. The appointment must seek prior mutual agreement between client and KCC Paints Sdn. Bhd. Their findings may be treated as conclusive, or the procedure may be repeated until a satisfactory conclusion can bemutually accepted between client and KCC Paints Sdn Bhd.

    3.5 Any Third party costs, in particular under clause 3.4, will be shared equally between client and KCC Paints Sdn. Bhd.

    4.0 PERIODIC CLEANING

    Periodic cleaning of the exterior surface is essential to maintain the aesthetic and durability of the coating system. Atmosphericdirt in the air can accumulate on flat areas like top of parapet, edges and ledges and with presence of rainwater, unsightly streak marks may be visible on light colours. Over passage of time, the accumulation of dirt and organic matter together withhigh moisture can promote the growth of algae although the paint can still be intact. The frequency of cleaning should preferably be least 12 (twelve) months interval depending environmental condition.

    5.0 SCHEDULE 1 (The Proposed System) Surface Preparation

    5.3 All new concrete plaster/masonry must be allowed dry out completely for at least 28 days.

    5.5 Apply one (1) coat of Supro wall sealer 100 follow by two (2) coats of Korevon & Supro Korever Exterior Acrylic paint.

    Our recommendation are as follows:a. Wash away loose dirt, dust and other contaminants with mild detergent ( 3 % to 5% dilution ) or clean water. b. Apply KCC Fungicidal Wash and allow to stand overnight.c. Clean away the fungicidal wash with clean water.

    5.1 Make good minor defects with suitable exterior grade Filler.5.2 Use Selleys No More Gaps to fill up all hairline cracks, gaps between window frames and walls, etc.

    5.4 Previously painted surfaces:- All areas affected by mould, lichen algae and moss are to be treated with KCC Fungicidal Wash. - Remove all loose or defective paint or powdery residues by thorough brushing and scraping, using a high pressure water jet.

    2.0 EXCLUSION OF PRODUCT WARRANTY

    2.1 The warranty shall not cover defects caused directly or indirectly by any one or more of the factors defined below. Such defects will not qualify for claims under the warranty and shall be deemed invalid claims. 2.1.1 Enggagement of poorly supervised or detective workmanship in the execution of work. It is strongly recommended that

    the client is to sign a seperate warranty on workmanship with their appointed application as the scope of this warranty onlycovering product quality.

    2.1.2 Under usage of paint materials resulting inadoquate lavel of protection done to lower film thickness applied.

    2.1.3 Damage of the coated surface caused by vandalism or by heavy impact , fire ,natural calamities, Act of God or normal wear and tear.

    2.1.4 Deterioration of paint including but not limited to staining, efflorescence, fungus growth caused from constant dampness around and within the walls from air condition, high moisture retention caused from water ponding, seepageor defects of similar nature or inadequate or improper surface preparation.

    2.1.5 Uniform or even colour change.2.1.6 Surface deposition of fungus, dirt or any contaminant that can be removed through periodic cleaning. Fungus and

    algae growth that can be washed off is classified as a foreign layer deposited on the paint film.

    2.1.7 Defects arising from work (alteration/extension) carried out onto the so affected areas of the building without the priorwritten agreement of KCC Paints.

    2.1.8 Staining or discoloration caused from polluted atmosphere, undetected water or moisture from within the substrate, or from window screens, metal gutters, spout pipes, water down-pipes, etc.

    2.1.9 Trace difference in colour or texture on new materials being supplied for repair work against previous material.

    2.1.10 Due to poor workmanship, negligence or non-conformance to the paint specification.