perkin-elmer
TRANSCRIPT
PRESSURE
are RETTER
• LEAKTIGHT to 250 psi
• NO COLD FLOW LEAKAGE
• NO DEAD VOLUME
• FRONT VALVE for storage
• REAR PLUNGER STOP
• INTERCHANGEABLE PARTS
^ PRECISION SAMPLING
C O R P O R A T I O N
P. O. BOX 15119 • BATON ROUGE, LOUISIANA 70815
Send me more i n f o rma t i on on why Pressure-Lol: gas syringes are be t te r .
NAME
T ITLE
C O M P A N Y -
AODRESS_
CITY
A C S L a b G u i d e See ad , page 2 4 7 Circle No. 142 on Readers' Service Card
New Products
circuit that holds and displays photometric values at the optimum time. Single- and triple-pass optics are also offered. Model 440 is a single-beam instrument and offers the major features of Model 444. Model 448 is designed to fit limited budgets. Concentration is presented directly on a meter and the instrument is designed with single-pass coated optics. The burners featured in the spectrophotometers are Model 405, the Autolam, and the Autolam-S. Beckman Instruments, Inc., 2500 Harbor Blvd., Fullerton, Calif. 92034 413
A Protein Sequenator incorporates solid state program control to provide error-free sequencing in accordance with the Edman Method. The system selected can be either fully automatic using the program board or completely manual. The instrument can be set for single-cycle operation or an auto-reset cycle can be set after any stage number. An internal control system constantly monitors key functions, and 41 projected readout or indicator lights continuously display the function being performed by the Sequenator. Additional features are 40 independent stages individually adjustable from 0.05 to 50 minutes in 0.05 minute increments and 20 output functions. Illitron, 2501 N. Keeler Ave., Chicago, III. 60639 414
Specific Ion Meter
Model 407 is capable of direct readout of total concentration as well as ionic concentration and activity, pi J, and millivolts. The 407 has a special scale that makes possible 2-minute total concentration measurements as precise as measurements using titration or colorimetric methods. A small known volume of a concentrated solution is added to an unknown and the initial concentration of the unknown is then read directly on the special 407 scale. No computation is required. The reagent added mav be either a solution
FROM COLEMAN... NEW
LOW TEMPERATURE R-F REACTOR
Removes organic matter without loss of volatile elements
MODEL 40
LOW TEMPERATURE
R-F REACTOR
Clean, dry, low-temperature R-F ash ng w i th Model 40 is far superior to we t and muff le furnace a s h i n g —i t 's the ideal w a y to prepare sampies for e lementa l analysis, air pol lut ion tests and microscopy without alteration of mineral or physical structure. Other appl icat ions include radio-c h e m i s t r y , a u t o r a d i o g r a p h y , r e a c t i o n c h e m i s t r y , a l t e r i n g mo lecu la r s t ruc tu re of p las t ic s u r f a c e s , p l a s m a c h e m i s t r y , removal of photoresist. Request Bulletin A-322.
Write to Coleman Instruments, Division of The Perkin-Elmer Corporation, 42 Madison St., Maywood, Illinois 60153
PERKIN-ELMER
Circle No. 23 on Readers' Service Card
108 A • ANALYTICAL CHEMISTRY
Lllh
NO. 306O0I-A VOL. 1 CC.
S36.00