ELEKTRIKAL Kepentingan elektrik. Penjanaan tenaga elektrik. Jenis-jenis stesen janakuasa. Jenis-jenis janakuasa. Jenis-jenis stesen janakuasa di Malaysia. Pendawaian perumahan & perindustrian. Simbol - simbol komponen elektrikal. Hukum ohm’s

Page 3: Modul2 120201023117-phpapp02

PENGENALAN

KEPENTINGAN DAN KEPERLUAN TENAGA ELEKTRIK DALAM

KEHIDUPAN SEHARIAN MANUSIA.

DALAM ZAMAN SERBA MODEN INI MANUSIA MEMENTINGKAN KESELESAAN DALAM KEHIDUPANNYA.

Page 4: Modul2 120201023117-phpapp02

PELBAGAI JENIS PERKAKAS ELEKTRIK DAN ELEKTRONIK DICIPTA UNTUK MEMENUHI KEPERLUAN TERSEBUT.

SETIAP HARI KITA MENGGUNAKAN PERKAKAS ELEKTRIK DAN ELEKTRONIK SEPERTI:-

Page 6: Modul2 120201023117-phpapp02

TENAGA ELEKTRIK MERUPAKAN SUMBER UTAMA BAGI

PENGHASILAN TENAGA LAIN .

APABILA MEMBERI TENAGA ELEKTRIK KEPADA MOTOR COMPRESSOR , PEMAMPATAN AKAN BERLAKU , PEMAMPATAN ITU ADALAH TENAGA MEKANIKAL .

APABILA MEMBERI TENAGA ELEKTRIK KEPADA LAMPU KALIMANTAN , LAMPU TERSEBUT AKAN MENYALA DAN PENYALAAN ITU ADALAH TENAGA MEKANIKAL .

Page 7: Modul2 120201023117-phpapp02

KESEMUA PERKAKAS YANG DI ATAS MEMERLUKAN TENAGA ELEKTRIK

Page 8: Modul2 120201023117-phpapp02

PENJANAAN TENAGA ELEKTRIK

PENJANAAN MERUPAKAN PROSES PENGELUARAN TENAGA ELEKTRIK DENGAN JUMLAH YANG TINGGI,TERHASIL DARIPADA PEMOTONGAN FLUKS OLEH GEGELUNG YANG TERDAPAT PADA SESEBUAH PENJANA.

Page 9: Modul2 120201023117-phpapp02

FLUKS

Page 10: Modul2 120201023117-phpapp02

Apabila bahan pengalir kedudukan tegak ,pengaliran fluks mengalir dengan lancar dan bila bahan pengalir kedudukan melintang, pemotong fluks akan berlaku dan hal ini menyebabkan penghasilan arus elektrik. Besar atau kecil penghasilan kuasa elaktrik bergantung pemutaran bahan pengalir.

Page 11: Modul2 120201023117-phpapp02

NOTA :

TENAGA YANG MEWUJUDKAN TENAGA ELEKTRIK ADALAH TENAGA MEKANIKAL . TEMPAT PENGHASILAN ELEKTRIK ADALAH DARIPADA PENJANA KUASA .

Page 12: Modul2 120201023117-phpapp02

TERDAPAT 3 JENIS STESEN

JANAKUASA UTAMA DI

MALAYSIA IAITU :

Page 13: Modul2 120201023117-phpapp02

1. STESEN JANAKUASA HIDRO

2. STESEN JANAKUASA GAS

3. STESEN JANAKUASA TERMA

Page 14: Modul2 120201023117-phpapp02

STESEN JANAKUASA HIDRO

STESEN JANAKUASA HIDRO MENGGUNAKAN AIR DARIPADA EMPANGAN SEBAGAI

PENGGERAK UTAMANYA UNTUK MEMUSINGKAN KIPAS TURBIN .

Page 15: Modul2 120201023117-phpapp02

STESEN JANAKUASA GAS

STESEN JANAKUASA GAS MENGGUNAKAN UDARA BERTEKANAN TINGGI SEBAGAI

SUMBER PENGGERAK UTAMA BAGI MEMUTARKAN KIPAS TURBIN .

Page 16: Modul2 120201023117-phpapp02

STESEN JANAKUASA TERMA

STESEN JANAKUASA TERMA MENGGUNAKAN BAHAN API SEPERTI ARANG BATU . DANDANG

AKAN MENGELUARKAN STIM YANG BERTEKANAN TINGGI BAGI MEMUTARKAN

KIPAS TURBIN .

Page 17: Modul2 120201023117-phpapp02

BAHAN API

DANDANG / BOILER

SALURAN PAIP KIPAS

TURBIN

SHAFT PENJANA

R Y B

11KV11KV

Page 18: Modul2 120201023117-phpapp02

STEP UP TRANSFORMER ( PENGUBAH LANGKAH NAIK )

STEP DOWN TRANSFORMER ( PENGUBAH LANGKAH TURUN )

MENARA PYLON

SUBSTATION(PENCAWANG)

R Y BR Y B

220KV 11KV

Page 19: Modul2 120201023117-phpapp02

R Y B

STEP DOWN TRANSFORMER ( PENGUBAH LANGKAH TURUN )

SUBSTATION(PENCAWANG)

R Y B N

INPUT DELTA

OUTPUT STAR

R Y B N

11KV

240V

NEUTRAL0V

Page 20: Modul2 120201023117-phpapp02

R

Y

B

N

KAWASAN PERUMAHAN 1 FASA (240VAC)

KAWASAN PERINDUSTRIAN 3 FASA(415VAC)

PEMBEKALAN MELALUI TIANG ELEKTRIK

R N

NBYR

Page 21: Modul2 120201023117-phpapp02

NOTA :

VOLTAN TINGGI = ARUS RENDAH.

VOLTAN RENDAH = ARUS TINGGI .

Page 22: Modul2 120201023117-phpapp02

VOLTAN TEKANAN ELEKTRIK

ARUS PENGALIRAN ELEKTRIK

RINTANGAN TENTANGAN ARUS

PENERANGAN

Page 23: Modul2 120201023117-phpapp02

FASA NEUTRAL-1 FASA (SINGLE PHASE)

MERAH NEUTRAL = 240V AC

BIRU NEUTRAL = 240V AC

KUNING NEUTRAL = 240V AC

Page 24: Modul2 120201023117-phpapp02

FASA FASA-3 FASA (THREE PHASE)

MERAH KUNING = 415V AC

KUNING BIRU = 415V AC

BIRU MERAH = 415V AC

Page 25: Modul2 120201023117-phpapp02

PENJANAAN, PENGHANTARAN DAN PENGAGIHAN TENAGA

ELEKTRIK

Page 26: Modul2 120201023117-phpapp02

PEMBEKALAN TENAGA ELEKTRIK KEPADA PENGGUNA PERLU MELALUI PERINGKAT PENJANAAN,PENGHANTARAN DAN PENGAGIHAN.

TENAGA ELEKTRIK DIJANA DI STESEN JANAKUASA DAN DITINGKATKAN VOLTANYA SEBELUM DIHANTAR KE PENCAWANGAN MASUK UTAMA DI DESTINASI TERTENTU.

SEBELUM TENAGA ELEKTRIK DIAGIHKAN KEPADA PENGGUNA, VOLTAN AKAN DITURUNKAN KEPADA 415 V/240 V DI PENCAWANG PENGAGIHAN.

Page 27: Modul2 120201023117-phpapp02

LAZIMNYA TERDAPAT 2 JENIS PENJANAAN

IAITU :

PENJANAAN ARUS TERUS ( DIRECT CURRENT )

PENJANAAN ARUS ULANG ALIK ( ALTERNATIVE CURRENT )

Page 28: Modul2 120201023117-phpapp02

PENJANAAAN ARUS TERUS

ARUS TERUS IALAH ARUS YANG MENGALIR SATU ARAH . ( BENTUK GELOMBANG )

LAZIMNYA PENJANAAN ARUS TERUS BOLEH DIDAPATI DARIPADA :

BATERI ( SEL BASAH / SEL KERING )

TENAGA SURIA / MATAHARI

Page 29: Modul2 120201023117-phpapp02

PENJANAAAN ARUS ULANG ALIK

ARUS ULANG ALIK IALAH ARUS YANG SENTIASA BERUBAH ARAH PENGALIRANNYA MENGIKUT PERUBAHAN KUTUB SUMBER BEKALAN . ( BENTUK GELOMBANG )

PENJANAAN ARUS ULANG ALIK MERUPAKAN SUMBER UTAMA BEKALAN TENAGA ELEKTRIK DI MALAYSIA .

Page 30: Modul2 120201023117-phpapp02

ARUS ULANG-ALIK DIJANA DI STESEN JANAKUASA. DI

NEGARA KITA TERDAPAT TIGA JENIS STESEN JANAKUASA.

Page 31: Modul2 120201023117-phpapp02

KEUPAYAAN SESEBUAH STESEN JANAKUASA MENJANA KUASA ELEKTRIK BERGANTUNG KEPADA PENJANA DAN PENGGERAK UTAMANYA.

VOLTAN YANG DIHASILKAN ADALAH 10.5 kV HINGGA 11.0 kV. WALAU BAGAIMANAPUN, UNTUK MEMUDAHKAN PENYELARASAAN, NILAI TERSEBUT DITETAPKAN PADA KADAR 11kV.

Page 32: Modul2 120201023117-phpapp02

TENAGA MEKANIKAL DIPERLUKAN BAGI MEMUTARKAN KIPAS TURBIN, SUPAYA TURBIN MEMACU PENJANA ARUS ULANG-ALIK.

SISTEM YANG MEMBEKALKAN TENAGA MEKANIK INI DIKENALI SEBAGAI PENGGERAK UTAMA.

TERDAPAT BEBERAPA JENIS SUMBER PENGGERAK UTAMA, ANTARANYA TERMASUKLAH:-

Page 33: Modul2 120201023117-phpapp02

AIR

STIM

OMBAK

GAS

ANGIN

Page 34: Modul2 120201023117-phpapp02

AIR,GAS DAN ANGIN MERUPAKAN SUMBER SEMULA JADI, MANAKALA STIM PULA DIHASILKAN MELALUI PEMANASAN AIR OLEH BAHAN API SEPERTI:-

MINYAK DIESEL

ARANG BATU

GAS

Page 35: Modul2 120201023117-phpapp02

STESEN JANAKUASA YANG TERDAPAT DI

MALAYSIA1. SJ- SULTAN SALAHUDDIN ABDUL

AZIZ,KAPAR,SELANGOR : 1200 MEGAWATT (GAS)

2. SJ- SULTAN ISMAIL,PAKA,TERENGGANU : 900 MEGA WATT (GAS)

Page 36: Modul2 120201023117-phpapp02

3. SJ- SULTAN ISKANDAR,JOHOR : 605 MEGA WATT (TERMA)

4. SJ- TUANKU JAAFAR,PORT DICKSON,NEGERI SEMBILAN : 600 MEGA WATT (TERMA)

5. SJ- TANJUNG ARU,SABAH : 450 MEGA WATT (TERMA)

Page 37: Modul2 120201023117-phpapp02

6. SJ- SULTAN ISMAIL PETRA,KELANTAN : 400 MEGAWATT (HIDRO)

7. SJ- TEMENGGOR,PERAK : 348 MEGAWATT (HIDRO)

8. SJ- PERAI PULAU PINANG : 317 MEGAWATT (TERMA)

Page 38: Modul2 120201023117-phpapp02

9. SJ- SULTAN IDRIS,CAMERON HIGHLANDS,PAHANG : 150 MEGAWATT (HIDRO)

10. SJ- BATANG AI,SARAWAK : 90 MEGAWATT (HIDRO)

Page 39: Modul2 120201023117-phpapp02

ELEKTRIK

PENDAWAIAN RUMAH

( HOUSE WIRING )

PENDAWAIAN INDUSTRI

( INDSTRIAL WIRING )

240 VOLT ( AC )

1 FASA

415 VOLT ( AC )

3 FASA

Page 40: Modul2 120201023117-phpapp02

KOD WARNA ELEKTRIKAL

1 FASA

RED

BROWN

YELLOW

BLUE

WHITE

LIFE

BLUE

BLACK

EARTH GREEN

YELLOW

NEUTRAL

LIFE

Page 41: Modul2 120201023117-phpapp02

3 FASA

BLACK

LIFE

RED

YELLOW

BLUE

NEUTAL

GREEN GREEN

Page 42: Modul2 120201023117-phpapp02

LITAR KUASA RUMAH

CUT

OUT NEUTRAL LINK

K.W.H METER

MAINSWITCH

ELCB

MCB

MCB

MCB

MCB

TERMINAL NEUTRAL

TERMINAL EARTH

DISTRIBUTION FUSE BOX ( D.F.B )

SUIS

Page 43: Modul2 120201023117-phpapp02

CUT OUT = MEMUTUSKAN BEKALAN APABILA

BERLAKU LEBIHAN ARUS .

K.W.H

METER = MEREKODKAN JUMLAH ARUS YANG

DIGUNAKAN .

D.F.B = MENGAGIHKAN BEKALAN KE

BEBERAPA LITAR APABILA

BERLAKU LEBIHAN ARUS .

FUNGSI

Page 44: Modul2 120201023117-phpapp02

DFB = Distribution Fuse Box

( Kotak Fius Agihan )

KWH = Kilo Watt Hour Meter

( Meter Kilo Watt Jam )

ELCB = Earth Leakage Circuit Breaker

( Pemutus Litar Bocor Ke Bumi )

MCB = Miniature Circuit Breaker

( Pemutus Litar Kenit )

Page 45: Modul2 120201023117-phpapp02

BAHASA MELAYU

BAHASA INGGERIS

UNIT SIMBOL

VOLTAN VOTAGE V VOLT ( V )

ARUS CURRENT I AMPERE ( A )

RINTANGAN RESISTANCE R Ohm( Ω )

KUASA POWER P WATT ( W )

Page 46: Modul2 120201023117-phpapp02

SIMBOL-SIMBOL ELEKTRIK (PENDAWAIAN RUMAH)

1. - SUIS SEHALA

2.

- SUIS DUA HALA

3.

- SUIS PERANTARAN

4.

- SUIS TARIK

5. - SUIS UTAMA

Page 47: Modul2 120201023117-phpapp02

(6) - LAMPU KALIMANTAN

(7)-LAMPU KALIMANTAN

BERKEMBAR

(8) - LAMPU DINDING

(9) - KIPAS SILING

(10)

- KIPAS EKZOS

Page 48: Modul2 120201023117-phpapp02

Soket alur keluar 15 A

Sokit alur keluar 13 A

Ac

Earth (bumi)

Neutral link

Air con

Page 49: Modul2 120201023117-phpapp02

L – LIVE N – NEUTRAL E – EARTH AMP – AMPIER V – VOLTAGE C – CURRENT AC – ALTERNATIVE CURRENT DC – DIRECT CURRENT R – RESISTOR SSO – SWITCH SOCKET OUTLET TNB – TENAGA NATIONAL BERHAD DFB- DISTRIBUTION FIUS BOX

Page 50: Modul2 120201023117-phpapp02

Saiz Kabel Litar Kuasa Rumah

Page 51: Modul2 120201023117-phpapp02

8 lampu4 Lampu

1 Kipas exhaust

1 Kipas

6 Soket alur keluar

1 Air cond 1 water heater

Cut out

Kwh meter

Main switch

ELCB

6A 6A 6A 15A 20A 20A 20A

3 Lampu

2 Kipas

1 Loceng

Page 52: Modul2 120201023117-phpapp02

Sambungan Plug

Sambungan suis

3 co wire

13A fuse

Sambungan soket

Page 53: Modul2 120201023117-phpapp02

PEMUTUS LITAR BOCOR KE BUMI

APABILA BERLAKUNYA KEBOCORAN , ARUS PADA GELUNG L DAN GELUNG N TIDAK SEIMBANG .

DENGAN ITU GELUNG BERKENDALI KERANA MENDAPAT VOTAN ARUHAN .

INI MENYEBABKAN GELUNG Z BERKENDALI KERANA MENDAPAT TENAGA ELEKTRIK DARIPADA GELUNG L DAN SETERUSNYA MENARIK SUIS PEMUTUS LITAR KE KEDUDUKAN “TUTUP”

ARUS BOCOR AKAN MASUK KE BEBAN MELALUI PENGALIR PELINDUNG LITAR BUMI JIKA KEBOCORAN ITU BERLAKU ANTARA ARUS PENGALIR “HIDUP” DAN “BUMI”

Page 54: Modul2 120201023117-phpapp02

LAMPU KALIMANTAN

Page 55: Modul2 120201023117-phpapp02

LAMPU KALIMANTAN Lampu kalimantan mempunyai 4 bahagian yang penting iaitu , punca bekalan, pemula, tiub dan choke.

CHOKE Memberi voltan pada masa permulaan dan menghadkan arus mengalir. STARTER (PENGHIDUP) jika lampu kalimantan dihidupkan A dan B yang bertanda akan cantum antara satu sama lain ,ini bermakna starter itu menolong menghidupkan mentol.

Page 56: Modul2 120201023117-phpapp02

MENGENALPASTI MASALAH

Jika lampu kalimantan tidak fungsi, punca bekalan diperiksa dengan menggunakan meter perbagai pada julat 250v ac. Jika ada bekalan,seterusya choke diperiksa dengan meter perbagai pada julat ohm, jika ada keterusan,

seterusnya penghidup diperiksa dengan menggunakan kaedah gantian,jika penghidup tidak rosak , seterusnya tiub diuji dengan menggunakan kaedah gantian.

Page 57: Modul2 120201023117-phpapp02

MASALAH SEBABFius terbakar semasa lampu dihidupkan

Pemuat rosakTerdapat litar pintas di dalam litar

Lampu tidak mahu menyala selepas dihidupkan

Tiada bekalanElektrod putusPemuat rosak

Lampu gagal menyala

Tiub sudah lamaVoltan bekalan rendahPemula rosak

Lampu tidak menyala , elektrod masih berbara

Pemula rosak

Page 58: Modul2 120201023117-phpapp02

SETERIKA ELEKTRIK

( IRON BOX )

Seterika elektrik mempunyai 3 bahagian penting iaitu punca bekalan , elemen pemanas dan laras suhu .

Pertama , punca bekalan diperiksa dengan menggunakan meter pelbagai ( multimeter ) pada julat 250 VAC . Jika didapati ada bekalan keterusan , elemen pemanas diperiksa dengan menggunakan multimeter pada julat ohm .

Jika tiada bekalan , keterusan talian bekalan diperiksa dari palam ( plug ) ketamatan elemen pemanas . Jika didapati rosak ,sama ada palam ,fius ,atau talian baru digantikan .

Page 59: Modul2 120201023117-phpapp02

MASALAH SEBABSeterika tidak panas

Tiada bekalan Fius putusTalian bekalan terbukaLaras suhu rosakElemen pemanas rosak

Kepanasan tidak rata

Elemen pemanas rosakSkru pada tamatan rosak .

Page 60: Modul2 120201023117-phpapp02

CEREK ELEKTRIK

( WATER HEATER )

Cerek elektrik mempunyai 4 bahagian yang penting iaitu punca bekalan , suis , laras suhu dan elemen pemanas .

Pertama , voltan punca bekalan diperiksa dengan menggunakan meter pelbagai pada julat 250VAC . Jika ada bekalan ,keterusan elemen pemanas diperiksa dengan menggunakan multimeter pada julat ohm . Elemen digantikan dengan yang baru .

Page 61: Modul2 120201023117-phpapp02

Sekiranya ia rosak : pada peringkat awal tiada bekalan kuasa ,keterusan dari palam hingga ke tamatan pada pemanas diperiksa dengan menggunakan meter pelbagai pada julat ohm . Jika rosak , sama ada palam , fius atau talian digantikan .

Page 62: Modul2 120201023117-phpapp02

MASALAH SEBABAir tidak panas Tiada bekalan

kuasa Fius putusSuis rosakElemen pemanas rosak

Air tidak mendidih

Suis automatik rosak

Page 63: Modul2 120201023117-phpapp02

JENIS – JENIS METER

1. METER AMPERE ( A ) = METER AMPERE DIGUNAKAN UNTUK MENGUKUR ARUS DIDALAM LITAR .

2. METER VOLT ( V ) = METER VOLT DIGUNAKAN UNTUK MENGUKUR VOLTAN DI DALAM LITAR .

3. METER Ohm ( Ω ) = METER Ohm DIGUNAKAN UNTUK MENGUKUR RINTANGAN DI DALAM LITAR .

4. METER PELBAGAI ( MULTIMETER ) = METER PELBAGAI MERUPAKAN METER YANG BOLEH DIGUNAKAN UNTUK MENGUKUR PELBAGAI KUANTITI ELEKTRIK SEPERTI , ARUS , VOLTAN DAN RINTANGAN .

Page 64: Modul2 120201023117-phpapp02

Hukum ohm Hukum ohm ialah hukum yang paling asas dan

penting dalam teori elektrikal. Dengan mengunakan hukum ini kita dapat menentukan nilai rintangan,arus,voltan dan kuasa dalam sesuatu litar A.T dan A.U

FORMULA : V = I x R I = V R R = V I

Page 65: Modul2 120201023117-phpapp02

Untuk memudahkan kita mengingati formula ini ialah dengan merujuk formula baru ini .

FORMULA SEGI TIGA AJAIB :

V

I R

x

÷

Page 66: Modul2 120201023117-phpapp02

R = O.5 Ώ

I = 2A

V = I x R

V = 2 x 0.5

V = 1V

V = ?

R = 46 Ώ

I = ?

V = 100

I = V / R

I = 100 / 45

I = 2.2A

Page 67: Modul2 120201023117-phpapp02

R = ?

I = 1.5A

V = 200V

R = V / I

R = 200 / 1.5

R = 133.3Ώ

Page 68: Modul2 120201023117-phpapp02

SEMOGA BERJAYA SEKIAN TERIMA

KASIH