Malaysian Journal of Analytical Sciences, Vol. 7, No. 1 (2001) 139-149 ___________________________________________________________________________________________ Kajian kualiti air di sekitar Kawasan Perindustrian Subang Jaya dan Shah Alam, Lembah Kelang Mazlin Bin Mokhtar 1,2 , Ismail Bin Bahari 2 , Yap Chee Hoh 2 dan Agnes Poon 2 1 Institut Alam Sekitar dan Pembangunan (LESTARI) 2 Fakulti Sains dan Teknologi, Universiti Kebangsaan Malaysia, 43600 UKM Bangi, Selangor Darul Ehsan (Received 6 September 2000) Abstrak. Kajian kualiti air di kawasan perindustrian Subang Jaya (Kawasan Perindustrian Ultramine dan Sungai Penaga) dan Shah Alam (Seksyen 15) di sekitar perairan Sungai Klang telah dilakukan pada awal bulan September sehingga Disember 1999. Enam kali pensampelan iaitu dua kali semasa Hari Panas (HP) dan empat kali semasa Hari Hujan (HH) telah dilakukan. Sebanyak sepuluh stesen pensampelan telah dipilih dalam kajian ini iaitu Stesen SJ1 hingga Stesen SJ5 di Subang Jaya dan Stesen SA1 sehingga Stesen SA5 di Shah Alam. Parameter-parameter kualiti air dalam kajian ini melibatkan parameter yang diukur secara in situ iaitu suhu, pH, oksigen terlarut (DO) dan kekonduksian dan parameter kualiti air yang dianalisis dalam makmal iaitu warna, kekeruhan, jumlah pepejal terampai (TSS), minyak dan gris, permintaan oksigen kimia (COD), fosfat, nitrogen ammonia (N-NH 3 ), permintaan oksigen biokimia (BOD), plumbum dan kadmium berdasarkan kaedah piawai APHA. Objektif kajian ini adalah untuk menentukan paras kepekatan bahan pencemar dan membandingkannya mengikut Hari Panas (HP) dan Hari Hujan (HH). Hasil ujian ANOVA Faktor Tunggal menunjukkan perbezaan yang signifikan (p<0.05) bagi parameter suhu, kekonduksian, DO, warna, kekeruhan dan fosfat antara Hari Panas (HH) dengan Hari Hujan (HH). Secara keseluruhannya kualiti air di kebanyakan stesen pensampelan adalah sederhana tercemar (Kelas IV berdasarkan Indeks Kualiti Air, IKA, Jabatan Alam Sekitar Malaysia). Stesen SJ1 (27.32%) dan Stesen SA1 (30.15%) berada dalam Kelas V pada hari panas. Pada hari hujan, peningkatan IKA menunjukkan peningkatan kualiti air iaitu dalam julat IKA 37.66-54.19%. Hasil kajian juga dibandingan dengan Piawai Interim Kualiti Air Kebangsaan Malaysia (INWQS) dan Peraturan Efluen Kumbahan dan Perindustrian 1978, Akta Kualiti Alam Sekeliling 1974. Abstract. A study on the water quality of the industrial areas of Subang Jaya (Ultramine and Sungai Penaga Industrial Zones) and Shah Alam (Section 15) within the Klang River Valley had been carried out from September to December 1999. Six samplings on six dates were carried out consisting of two sunny days and four rainy days. During this study, ten sampling sites were chosen, they were Station SJ1 to Station SJ5 in Subang Jaya and Station SA1to Station SA5 in Shah Alam. The water quality parameters studied were in situ parameters of temperature, pH, dissolved oxygen (DO) and conductivity, and laboratory analyzed water quality parameters of colour, turbidity, total suspended solids (TSS), oil and grease, chemical oxygen demand (COD), phosphate, ammonical nitrogen (N-NH 3 ), biochemical oxygen demand (BOD), lead and cadmium, based on standard methods of APHA. The objectives of the study were to determine the concentration of pollutants and comparing the results of sunny days (HP) to those of rainy days (HH). Single factor ANOVA showes that there were significant differences (p<0.05) for temperature, conductivity, DO, colour, turbidity and phosphate between sunny and rainy days. Results showed that a majority of the sampling stations were polluted (Class IV based on WQI) except at Station SJ1 (27.32%) and Station SA1 (30.15%) which were classified as Class V (very polluted) during sunny days. During rainy days, higher WQI indicates that the quality of the water have improved, these were in the range of WQI 37.66-54.19%. Data obtained in this study were also ompared with the Interim National Water Quality Standards (INWQS) and Environment Quality Act, 1974 (Sewage & Industrial Effluent Regulation, 1978). ___________________________________________________________________________________________ Key words : Water Quality, Industrial Area, Subang Jaya, Shah Alam, Klang Valley Pengenalan Proses urbanisasi dan aktiviti perindustrian yang pesat dalam sesebuah negara berkecenderungan meluahkan pelbagai jenis efluen dan kumbahan ke dalam sistem air semulajadi dan ini menyebabkan berlakunya kejadian pencemaran air. Sungai Klang merupakan sungai yang penting dari segi sosio ekonomi negara Malaysia dan memainkan peranan yang penting dalam pembekalan air kepada penduduk di sekitar Lembah Klang. Kelodak merupakan pencemar utama di Sungai Klang dan didapati kepekatan pepejal terampai adalah tinggi kerana pembangunan yang pesat akibat pertumbuhan penduduk [1]. Punca pencemaran Sungai Klang yang kedua adalah pembuangan sisa dari kumbahan dan perindustrian. Objektif kajian ini adalah untuk (i) menentukan paras kepekatan bahan pencemar tertentu di beberapa lokasi dalam kawasan perindustrian ke atas perairan Sungai Klang, (ii) membandingkan paras kepekatan bahan pencemar semasa hari panas dan hari hujan, (iii) mengelaskan stesen pensampelan berdasarkan IKA,

Upload: vandang

Post on 12-Jan-2017

261 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: kajian kualiti air di sekitar kawasan perindustrian subang jaya dan

Malaysian Journal of Analytical Sciences, Vol. 7, No. 1 (2001) 139-149

___________________________________________________________________________________________

Kajian kualiti air di sekitar Kawasan Perindustrian Subang Jaya dan Shah Alam, Lembah Kelang

Mazlin Bin Mokhtar1,2, Ismail Bin Bahari2, Yap Chee Hoh2 dan Agnes Poon2

1Institut Alam Sekitar dan Pembangunan (LESTARI)

2Fakulti Sains dan Teknologi, Universiti Kebangsaan Malaysia, 43600 UKM Bangi, Selangor Darul Ehsan

(Received 6 September 2000)

Abstrak. Kajian kualiti air di kawasan perindustrian Subang Jaya (Kawasan Perindustrian Ultramine dan Sungai Penaga) dan Shah Alam (Seksyen 15) di sekitar perairan Sungai Klang telah dilakukan pada awal bulan September sehingga Disember 1999. Enam kali pensampelan iaitu dua kali semasa Hari Panas (HP) dan empat kali semasa Hari Hujan (HH) telah dilakukan. Sebanyak sepuluh stesen pensampelan telah dipilih dalam kajian ini iaitu Stesen SJ1 hingga Stesen SJ5 di Subang Jaya dan Stesen SA1 sehingga Stesen SA5 di Shah Alam. Parameter-parameter kualiti air dalam kajian ini melibatkan parameter yang diukur secara in situ iaitu suhu, pH, oksigen terlarut (DO) dan kekonduksian dan parameter kualiti air yang dianalisis dalam makmal iaitu warna, kekeruhan, jumlah pepejal terampai (TSS), minyak dan gris, permintaan oksigen kimia (COD), fosfat, nitrogen ammonia (N-NH3), permintaan oksigen biokimia (BOD), plumbum dan kadmium berdasarkan kaedah piawai APHA. Objektif kajian ini adalah untuk menentukan paras kepekatan bahan pencemar dan membandingkannya mengikut Hari Panas (HP) dan Hari Hujan (HH). Hasil ujian ANOVA Faktor Tunggal menunjukkan perbezaan yang signifikan (p<0.05) bagi parameter suhu, kekonduksian, DO, warna, kekeruhan dan fosfat antara Hari Panas (HH) dengan Hari Hujan (HH). Secara keseluruhannya kualiti air di kebanyakan stesen pensampelan adalah sederhana tercemar (Kelas IV berdasarkan Indeks Kualiti Air, IKA, Jabatan Alam Sekitar Malaysia). Stesen SJ1 (27.32%) dan Stesen SA1 (30.15%) berada dalam Kelas V pada hari panas. Pada hari hujan, peningkatan IKA menunjukkan peningkatan kualiti air iaitu dalam julat IKA 37.66-54.19%. Hasil kajian juga dibandingan dengan Piawai Interim Kualiti Air Kebangsaan Malaysia (INWQS) dan Peraturan Efluen Kumbahan dan Perindustrian 1978, Akta Kualiti Alam Sekeliling 1974.

Abstract. A study on the water quality of the industrial areas of Subang Jaya (Ultramine and Sungai Penaga Industrial Zones) and Shah Alam (Section 15) within the Klang River Valley had been carried out from September to December 1999. Six samplings on six dates were carried out consisting of two sunny days and four rainy days. During this study, ten sampling sites were chosen, they were Station SJ1 to Station SJ5 in Subang Jaya and Station SA1to Station SA5 in Shah Alam. The water quality parameters studied were in situ parameters of temperature, pH, dissolved oxygen (DO) and conductivity, and laboratory analyzed water quality parameters of colour, turbidity, total suspended solids (TSS), oil and grease, chemical oxygen demand (COD), phosphate, ammonical nitrogen (N-NH3), biochemical oxygen demand (BOD), lead and cadmium, based on standard methods of APHA. The objectives of the study were to determine the concentration of pollutants and comparing the results of sunny days (HP) to those of rainy days (HH). Single factor ANOVA showes that there were significant differences (p<0.05) for temperature, conductivity, DO, colour, turbidity and phosphate between sunny and rainy days. Results showed that a majority of the sampling stations were polluted (Class IV based on WQI) except at Station SJ1 (27.32%) and Station SA1 (30.15%) which were classified as Class V (very polluted) during sunny days. During rainy days, higher WQI indicates that the quality of the water have improved, these were in the range of WQI 37.66-54.19%. Data obtained in this study were also ompared with the Interim National Water Quality Standards (INWQS) and Environment Quality Act, 1974 (Sewage & Industrial Effluent Regulation, 1978). ___________________________________________________________________________________________ Key words : Water Quality, Industrial Area, Subang Jaya, Shah Alam, Klang Valley

Pengenalan Proses urbanisasi dan aktiviti perindustrian yang pesat dalam sesebuah negara berkecenderungan meluahkan pelbagai jenis efluen dan kumbahan ke dalam sistem air semulajadi dan ini menyebabkan berlakunya kejadian pencemaran air. Sungai Klang merupakan sungai yang penting dari segi sosio ekonomi negara Malaysia dan memainkan peranan yang penting dalam pembekalan air kepada penduduk di sekitar Lembah Klang. Kelodak merupakan pencemar utama

di Sungai Klang dan didapati kepekatan pepejal terampai adalah tinggi kerana pembangunan yang pesat akibat pertumbuhan penduduk [1]. Punca pencemaran Sungai Klang yang kedua adalah pembuangan sisa dari kumbahan dan perindustrian. Objektif kajian ini adalah untuk (i) menentukan paras kepekatan bahan pencemar tertentu di beberapa lokasi dalam kawasan perindustrian ke atas perairan Sungai Klang, (ii) membandingkan paras kepekatan bahan pencemar semasa hari panas dan hari hujan, (iii) mengelaskan stesen pensampelan berdasarkan IKA,

Page 2: kajian kualiti air di sekitar kawasan perindustrian subang jaya dan

MAZLIN MOKHTAR et al.: KAJIAN KUALITI AIR DI SEKITAR KAWASAN PERINDUSTRIAN

140

RAJAH 1 : Lokasi Stesen Persampelan SJ1 hingga SJ5 di Kawasan Perindustrian Subang Jaya di Sekitar Perairan Sungai Klang

Sungai

Jalan Negeri Major

Lebuh RayaPersekutuan

Jalan Kecil

Stesen Persampelan

Sistem Saliran

PETUNJUK

UTARASkala Peta 1cm : 170m

USJ2 USJ1

USJ6

USJ7

KawasanPerindustrianSungaiPenaga

USJ8

KawasanPerindustrianUltramine

SJ1

Sungai Klang

SJ4

SJ5SJ3

SJ2

USJ14

USJ15

Taman IndahSubang UEP

Page 3: kajian kualiti air di sekitar kawasan perindustrian subang jaya dan

MAZLIN MOKHTAR et al.: KAJIAN KUALITI AIR DI SEKITAR KAWASAN PERINDUSTRIAN

141

Rajah 2 : Lokasi Stesen Persampelan SA1 hingga SA5 di Kawasan PerindustrianShah Alam di Sekitar Perairan Sungai Klang

PETUNJUK

SungaiJalan Negeri MajorLebuh Raya PersekutuanJalan KecilStesen PersampelanSistem Saliran

SungaiKlang

Seksyen 18

Sungai Renggam

SA5

SA4SA3

SA2

Seksyen 17

SA1Seksyen 16Seksyen 15

Skala peta 1 cm: 100 m

UTARA

Page 4: kajian kualiti air di sekitar kawasan perindustrian subang jaya dan

MAZLIN MOKHTAR et al.: KAJIAN KUALITI AIR DI SEKITAR KAWASAN PERINDUSTRIAN

dan (iv) membuat perbandingan dengan piawai INWQS dan Akta Kualiti Alam Sekeliling, 1974 (Peraturan Efluen Kumbahan dan Perindustrian, 1978).

Bahan dan Kaedah Stesen Pensampelan Sepuluh stesen pensampelan telah dipilih di kawasan perindustrian Subang Jaya (SJ1-SJ5) dan Shah Alam (SA1-SA5). Stesen pensampelan yang dipilih adalah mengikut kedudukan punca pembuangan air efluen dari kawasan perindustrian yang merangkumi sistem parit dan sungai. Sisa dari Kawasan Perindustrian Subang Jaya disalirkan keluar ke dalam parit yang kemudian mengalirkan sisa tersebut ke dalam Sungai Klang. Sisa dari Kawasan Perindustrian Shah Alam bermula dari sistem parit dan memasuki Sungai Renggam iaitu cabang kepada Sungai Klang dan berakhir di dalam Sungai Klang. Rajah 1 dan Rajah 2 menunjukkan kedudukan stesen-stesen pensampelan kajian ini. Kaedah Kajian air sungai melibatkan pengukuran beberapa parameter kualiti air secara in situ iaitu suhu, pH, oksigen terlarut dan kekonduksian. Pengambilan sampel air sungai di stesen-stesen kajian dilakukan antara jam 0800 hingga jam 1300. Sampel air tersebut dihantar ke makmal untuk analisis dalam menentukan kepekatan BOD, COD, TSS, ammonia, warna, plumbum, kadmium dan fosfat.

Kaedah analisis di makmal adalah berdasarkan kepada kaedah piawai yang disarankan oleh APHA [2]. Meter boleh bimbit telah digunakan dalam pengukuran parameter secara in situ. Alat-alat analisis di makmal yang telah digunakan dalam kajian ini merangkumi spektrofotometer HACH DR2000, alat kaca, kukus air, neraca elektronik, set refluks dan ketuhar. Spektrofotometer serapan atom jenis bukan nyala (Perkin Elmer 4100ZL) telah digunakan dalam analisis logam plumbum dan kadmium.

Sebelum melakukan pensampelan, botol polietilena, botol kaca dan botol khas untuk BOD terlebih dahulu dibersihkan dengan larutan asid nitrik (HNO3) 14% (i/i) dan direndam selama 24 jam dalam bekas polietilena dan diikuti dengan bilasan air suling sebanyak tiga kali. Pensampelan menggunakan baldi dilakukan di lokasi yang sukar diakses seperti stesen-stesen di Sungai Kelang. Baldi dan botol pensampelan dibersihkan dan dibilas dengan air sungai di stesen pensampelan sebelum diisikan dengan sampel air sungai tersebut. Gelembung udara dipastikan tidak terperangkap dalam botol yang mengandungi sampel air semasa proses pengisian. Sarung tangan dipakai

semasa pensampelan untuk mengelakkan kontaminasi sampel.

Sampel air dituras dengan membran turasan bersaiz liang 0.45 µm dan disejukkan pada suhu kurang dari 4ºC sehingga analisis dapat dijalankan. Kesemua botol sampel dilabelkan dengan nombor stesen, tarikh dan masa pensampelan. Keadaan cuaca dan maklumat lain yang berkaitan dicatatkan dalam buku log lapangan.

Hasil dan Perbincangan Jadual 1, 2 dan 3 menunjukkan keputusan kajian ini bagi dua kali pensampelan sewaktu Hari Panas (HP) dan empat kali pensampelan sewaktu Hari Hujan (HH). Ujian ANOVA Faktor Tunggal menunjukkan terdapat perbezaan signifikan (p<0.05) untuk perbandingan paras kepekatan antara hari panas dengan hari hujan iaitu bagi parameter suhu, kekonduksian, oksigen terlarut, warna, kekeruhan dan fosfat. Jadual 4 menunjukkan pengelasan stesen pensampelan berdasarkan Indeks Kualiti Air (IKA), Jabatan Alam Sekitar Malaysia, bagi Hari Panas (HP) dan Hari Hujan (HH). Jadual 5 memaparkan perbandingan nilai cerapan kajian ini dengan nilai maksimum yang disarankan oleh Piawai Interim Kualiti Air Kebangsaan (INWQS). Jadual 6 menunjukkan kepekatan parameter kualiti air antara hari hujan dan hari kering di semua stesen pensampelan kajian ini berbanding EKP 1978 dan INWQS.

Terdapat perbezaan signifikan (p<0.05) bagi nilai suhu antara hari panas dan hari hujan. Perbezaan ini mungkin disebabkan oleh perbezaan suhu yang bergantung kepada cuaca, sinaran matahari, suhu udara sekeliling, kelembapan dan pergerakan angin [3]. Nilai purata kekonduksian yang dicerap pada Hari Panas (HP) adalah relatif tinggi berbanding dengan Hari Hujan (HH). Nilai kekonduksian adalah bergantung kepada kepekatan, pergerakan dan valensi sebatian-sebatian ionik terlarut dalam air serta suhu air ketika pengukuran dilakukan. Menurut Chapman [4], kekonduksian air permukaan biasanya berada dalam julat 10 µS/cm hingga 1000 µS/cm, tetapi mungkin melebihi nilai julat ini terutamanya dalam air yang tercemar atau sistem saliran yang menerima air larian permukaan.

Nilai purata kepekatan oksigen terlarut (DO) yang dicerap pada hari hujan adalah lebih tinggi (p<0.05) berbanding hari panas kerana suhu sewaktu hari hujan adalah lebih rendah dan pergolakan arus air yang lebih aktif sewaktu hari hujan menggalakkan pemelarutan oksigen dalam air tersebut. Oksigen hanya sedikit larut dalam air dan perubahan suhu air mempengaruhi kepekatan DO (r2 = - 0.341) dalam air.

142

Page 5: kajian kualiti air di sekitar kawasan perindustrian subang jaya dan

MAZLIN MOKHTAR et al.: KAJIAN KUALITI AIR DI SEKITAR KAWASAN PERINDUSTRIAN

Semakin tinggi suhu air maka semakin menurun kelarutan oksigen dalam air tersebut [5].

Purata kepekatan warna dan kekeruhan menunjukkan nilai yang relatif lebih rendah pada hari hujan berbanding hari panas kerana faktor pencairan semasa hari hujan. Namun Stesen SJ4 dan Stesen SJ5 menunjukkan peningkatan nilai pada hari hujan mungkin disebabkan berlakunya hakisan tanah di tebing sungai yang terdedah kepada hujan akibat kerja pembinaan konkrit tebing pada waktu pensampelan dijalankan.

Paras kepekatan parameter kajian antara stesen pensampelan Stesen SJ1 mempunyai nilai purata pH yang terendah pada hari panas (6.42 ± 0.02) dan hari hujan (6.82 ± 0.16). Stesen ini terletak berdekatan dengan kilang pembuatan logam yang mungkin telah menyumbangkan efluen yang mempunyai nilai pH rendah [7]. Pada hari hujan nilai purata bagi pH yang dicerap di semua stesen pensampelan adalah relatif lebih tinggi berbanding hari panas.

Jadual 1 : Nilai bacaan suhu, pH, kekonduksian dan oksigen terlarut (DO)

Suhu ( °C) pH Kekonduksian (µS/cm)

Oksigen terlarut (mg/L)

Stesen HP HH HP HH HP HH HP HH

SJ1 26.0±1.0 25.9±1.1 6.42±0.02 6.82±0.16 378.44±178.52 203.43±29.39 0.02±0.03 0.57±0.47

SJ2 26.4±1.6 26.2±0.6 7.06±0.28 7.28±0.14 387.05±20.58 299.21±77.25 0.60±0.85 2.71±0.57

SJ3 27.5±1.8 26.4±1.1 6.59±0.27 6.83±0.03 363.83±231.93 270.74±76.16 1.88±0.03 1.74±0.99

SJ4 29.9±1.4 28.2±1.3 7.20±0.04 7.11±0.09 348.95±56.07 234.44±52.78 0.46±0.65 1.42±0.89

SJ5 29.9±1.2 28.1±1.3 7.24±0.01 7.10±0.09 348.39±50.51 231.99±66.38 0.44±0.62 1.35±0.85

SA1 31.2±1.8 30.1±1.0 7.19±0.10 7.20±0.12 491.29±67.01 448.10±34.20 0.05±0.02 1.68±1.20

SA2 32.5±2.8 30.3±1.5 6.98±0.09 7.02±0.03 499.57±110.92 431.87±52.43 0.15±0.09 1.34±0.99

SA3 32.2±2.5 29.6±1.5 7.09±0.19 7.09±0.05 504.82±131.78 452.06±49.86 0.62±0.07 0.63±0.66

SA4 31.8±2.4 28.6±1.6 6.97±0.10 7.01±0.13 418.12±171.90 222.43±50.83 0.28±0.39 1.35±1.72

SA5 31.7±2.1 28.4±1.4 6.93±0.04 6.99±0.02 448.44±212.46 224.11±56.07 0.25±0.35 1.05±1.35

Nilai purata

29.9±2.4 28.2±1.6 6.93±0.27 7.05±0.15 418.89±62.85 301.84±101.81 0.47±0.54 1.38±0.61

Jadual 2: Kepekatan warna, kekeruhan, TSS dan minyak dan gris

Warna (Pt-Co) Kekeruhan (FTU) TSS (mg/L) Minyak dan gris (mg/L)

Stesen HP HH HP HH HP HH HP HH

SJ1 181.33±107.48 98.67±58.12 37.67±27.81 17.25±11.00 42.65±15.06 16.15±5.06 68.00±50.35 10.00±6.57

SJ2 241.17±100.18 45.99±22.12 51.50±30.41 8.51±4.00 28.65±18.88 13.00±5.07 92.20±0.28 6.45±4.52

SJ3 65.84±9.67 48.00±8.15 12.34±0.47 8.25±1.85 20.15±9.69 10.83±4.63 82.80±3.96 3.80±3.70

SJ4 204.67±36.77 213.25±46.00 39.50±16.26 42.00±10.80 42.65±4.74 57.03±19.89 71.40±38.75 5.80±2.32

SJ5 203.84±4.01 210.42±56.76 37.17±10.13 39.08±11.42 39.85±7.28 58.00±19.11 55.20±56.00 11.40±11.98

SA1 144.17±4.48 99.34±19.75 27.34±5.18 19.00±4.49 45.85±6.86 36.18±9.06 64.20±43.84 4.30±2.54

SA2 131.50±13.90 62.83±34.15 24.00±1.41 11.92±6.84 41.35±9.41 29.35±6.31 57.40±55.15 5.70±2.62

SA3 139.50±2.12 95.17±34.16 25.17±0.23 16.67±5.76 38.00±11.31 29.10±7.01 55.20±50.91 5.40±3.04

SA4 272.50±16.26 195.42±37.80 55.84±15.32 36.42±10.69 60.85±39.39 45.70±11.94 56.20±49.50 11.00±10.61

SA5 295.00±21.21 194.75±46.51 59.00±7.07 36.83±14.33 59.50±37.48 49.35±15.26 61.00±60.25 5.50±4.66

Nilai purata

187.95±70.22 126.38±69.26 36.95±15.15 23.59±13.45 41.95±12.27 34.47±17.71 66.36±12.61 6.94±2.79

143

Page 6: kajian kualiti air di sekitar kawasan perindustrian subang jaya dan

MAZLIN MOKHTAR et al.: KAJIAN KUALITI AIR DI SEKITAR KAWASAN PERINDUSTRIAN

Jadual 3: Kepekatan COD, Fosfat, N-NH3, BOD, Plumbum dan Kadmium

COD (mg/L) Fosfat (mg/L) N-NH3 (mg/L) BOD (mg/L) Plumbum (µg/L) Kadmium (µg/L)

Stesen HP HH HP HH HP HH HP HH HP HH HP HH

SJ1 262.75±5.55 155.63±138.80 4.08±3.67 0.48±0.37 13.27±1.61 2.78±0.93 23.60±1.84 14.98±1.78 0.50±0.00 1.38±2.75 0.03±0.04 0.65±0.74

SJ2 35.29±5.55 46.42±31.53 1.02±1.11 2.05±1.47 13.40±0.89 3.69±3.42 11.15±1.34 6.43±0.75 0.25±0.35 1.00±1.68 0.00±0.00 0.11±0.05

SJ3 7.84±5.55 34.01±15.60 2.38±0.21 2.01±1.37 10.52±1.07 7.46±2.45 10.60±0.99 6.55±0.96 0.25±0.35 1.38±2.75 0.28±0.40 0.16±0.14

SJ4 13.73±2.77 25.87±13.83 1.87±0.71 1.34±0.77 7.13±0.57 8.75±2.79 14.60±0.85 6.93±2.10 1.50±1.41 1.25±2.18 0.40±0.24 0.14±0.17

SJ5 192.16±49.91

18.23±11.75 5.50±5.71 2.16±1.68 6.72±1.29 5.73±2.28 14.90±0.14 6.28±1.11 2.00±0.71 1.13±2.25 0.23±0.32 0.04±0.05

SA1 149.02±5.55 91.44±39.78 2.66±0.06 4.12±1.65 9.52±1.01 5.33±0.97 21.55±1.34 11.03±1.73 2.25±3.18 5.00±6.12 0.00±0.00 0.11±0.16

SA2 50.98±5.55 87.31±58.37 4.41±3.91 2.34±1.21 6.95±0.92 3.73±1.09 20.20±0.57 12.38±3.68 0.75±1.06 2.00±2.38 0.08±0.12 0.04±0.05

SA3 70.59±5.55 57.97±28.11 4.18±4.13 1.99±1.36 7.44±1.08 3.19±1.39 12.85±2.05 12.43±2.61 0.75±1.06 4.50±6.36 0.08±0.12 0.27±0.36

SA4 27.46±5.54 40.43±24.82 2.29±0.44 1.74±1.44 4.50±0.75 1.81±1.54 9.65±0.64 7.90±0.91 3.25±4.60 3.00±5.05 0.08±0.12 0.01±0.03

SA5 9.80±8.32 11.95±6.49 2.71±0.13 1.20±1.51 5.00±0.42 4.02±2.56 9.85±0.07 7.60±1.15 1.25±1.77 1.13±0.75 0.11±0.16 0.10±0.13

Nilai purata

81.96±88.77 56.92±36.91 3.11±1.37 1.94±0.95 8.84±3.14 4.65±2.17 14.90±5.14 9.25±3.16 1.28±0.98 2.18±1.48 0.13±0.13 0.16±0.19

Jadual 4: Indeks Kualiti Air (IKA) pada Hari Panas (HP) dan Hari Hujan (HH) Hari Panas (HP)

Stesen DO (mg/L)

BOD (mg/L)

COD (mg/L)

TSS (mg/L)

N-NH3 (mg/L)

PH Unit

Indeks DO

Indeks BOD

Indeks COD

Indeks TSS

Indeks N-NH3

Indeks pH

IKA Kelas Sungai

Status Sungai

SJ1 0.02 23.60 262.75 42.65 13.27 6.42 0.00 27.13 -8.85 75.21 0.00 96.20 27.32 V Tercemar

SJ2 0.60 11.15 35.29 28.65 13.40 7.06 0.00 57.38 57.77 81.77 0.00 99.19 45.13 IV Sederhana tercemar

SJ3 1.88 10.60 7.84 20.15 10.52 6.59 14.14 59.23 88.67 86.09 0.00 97.68 54.05 III Sedikit tercemar

SJ4 0.46 14.60 13.73 42.65 7.13 7.20 0.00 46.92 80.84 75.21 0.00 98.65 45.72 IV Sederhana tercemar

SJ5 0.44 14.90 192.16 39.85 6.72 7.24 0.00 46.10 -2.64 76.47 0.00 98.45 32.39 IV Sederhana tercemar

SA1 0.05 21.55 149.02 45.85 9.52 7.19 0.00 30.86 3.96 73.81 0.00 98.69 30.15 V Tercemar

SA2 0.15 20.20 50.98 41.35 6.95 6.98 0.00 33.54 44.22 75.79 0.00 99.62 37.53 IV Sederhana tercemar

SA3 0.62 12.85 70.59 38.00 7.44 7.09 1.65 51.99 31.18 77.31 0.00 99.09 39.49 IV Sederhana tercemar

SA4 0.28 9.65 27.46 60.85 4.50 6.97 0.00 62.56 65.83 67.66 0.00 99.60 45.20 IV Sederhana tercemar

SA5 0.25 9.85 9.80 59.50 5.00 6.93 0.00 61.84 86.06 68.19 0.00 99.49 48.37 IV Sederhana tercemar

Hari Hujan (HH)

SJ1 0.57 14.98 155.63 16.15 2.78 6.82 1.02 45.88 2.72 88.22 15.21 99.07 37.66 IV Sederhana tercemar

SJ2 2.71 6.43 46.42 13.00 3.69 7.28 25.62 75.19 47.84 89.95 2.90 98.23 54.19 III Sedikit tercemar

SJ3 1.74 6.55 34.01 10.83 7.46 6.83 11.43 74.68 59.03 91.16 0.00 99.12 52.63 III Sedikit tercemar

SJ4 1.42 6.93 25.87 57.03 8.75 7.11 8.28 73.08 67.59 69.16 0.00 99.02 49.47 IV Sederhana tercemar

SJ5 1.35 6.28 18.23 58.00 5.73 7.10 7.51 75.83 74.86 68.78 0.00 99.06 50.93 IV Sederhana tercemar

SA1 1.68 11.03 91.44 36.18 5.33 7.20 12.23 57.78 20.85 78.15 0.00 98.65 41.35 IV Sederhana tercemar

SA2 1.34 12.38 87.31 29.35 3.73 7.02 7.92 53.43 22.66 81.42 2.44 99.30 40.83 IV Sederhana tercemar

SA3 0.63 12.43 57.97 29.10 3.19 7.09 1.57 53.27 39.13 81.54 9.16 99.09 43.04 IV Sederhana tercemar

SA4 1.35 7.90 40.43 45.70 1.81 7.01 7.76 69.15 52.98 73.87 32.37 99.33 51.92 III Sedikit tercemar

SA5 1.05 7.60 11.95 49.35 4.02 6.99 4.52 70.34 83.21 72.31 0.00 99.65 51.20 IV Sederhana tercemar

144

Page 7: kajian kualiti air di sekitar kawasan perindustrian subang jaya dan

MAZLIN MOKHTAR et al.: KAJIAN KUALITI AIR DI SEKITAR KAWASAN PERINDUSTRIAN

Jadual 5: Perbandingan nilai cerapan dan pengukuran kajian ini dengan Piawai Interim Kualiti Air Kebangsaan (INWQS)

Hari Panas (HP) Stesen DO

(mg/L) Sub-kelas

BOD (mg/L)

Sub-kelas

COD (mg/L)

Sub-kelas

TSS (mg/L)

Sub- kelas

N-NH3 (mg/L)

Sub-kelas

pH Unit

Sub-kelas

SJ1 0.02 V 23.60 V 262.75 V 42.65 II 13.27 V 6.42 I SJ2 0.60 V 11.15 III 35.29 III 28.65 II 13.40 V 7.06 I SJ3 1.88 IV 10.60 III 7.84 I 20.15 I 10.52 V 6.59 I

SJ4 0.46 V 14.60 IV 13.73 II 42.65 II 7.13 V 7.20 II SJ5 0.44 V 14.90 IV 192.16 IV 39.85 II 6.72 V 7.24 II SA1 0.05 V 21.55 V 149.02 IV 45.85 II 9.52 V 7.19 II

SA2 0.15 V 20.20 V 50.98 IV 41.35 II 6.95 V 6.98 I SA3 0.62 V 12.85 IV 70.59 IV 38.00 II 7.44 V 7.09 II SA4 0.28 V 9.65 III 27.46 III 60.85 II 4.50 V 6.97 I SA5 0.25 V 9.85 III 9.80 I 59.50 II 5.00 V 6.93 I

Hari Hujan (HH)

SJ1 0.57 V 14.98 IV 155.63 IV 16.15 I 2.78 V 6.82 I SJ2 2.71 IV 6.43 III 46.42 III 13.00 I 3.69 V 7.28 II SJ3 1.74 IV 6.55 III 34.01 III 10.83 I 7.46 V 6.83 I SJ4 1.42 IV 6.93 III 25.87 III 57.03 III 8.75 V 7.11 II SJ5 1.35 IV 6.28 III 18.23 II 58.00 III 5.73 V 7.10 II SA1 1.68 IV 11.03 III 91.44 IV 36.18 II 5.33 V 7.20 II SA2 1.34 IV 12.38 IV 87.31 IV 29.35 II 3.73 V 7.02 II SA3 0.63 V 12.43 IV 57.97 IV 29.10 II 3.19 V 7.09 II

SA4 1.35 IV 7.90 III 40.43 II 45.70 II 1.81 IV 7.01 II SA5 1.05 IV 7.60 III 11.95 II 49.35 II 4.02 V 6.99 I

Ini adalah disebabkan oleh air larian permukaan yang melarutkan batu kapur yang terkandung dalam batu-batan atau dalam tanah yang menyebabkan air sungai bersifat sedikit alkali [8]. Stesen SJ4 (pH 7.11 ± 0.09) dan SJ5 (pH 7.10 ± 0.09) mencatatkan nilai purata pH yang relatif rendah pada hari hujan mungkin disebabkan oleh air hujan yang memerangkap karbon dioksida dalam atmosfera dan membentuk asid karbonik yang meningkatkan kepekatan ion H+ dalam air [8].

Purata kepekatan jumlah pepejal terampai (TSS) di Stesen SJ4 (49.84 mg/L) dan SJ5 (48.93 mg/L) merupakan stesen yang berdekatan dengan kilang pembuatan kertas. Menurut Mancy dan Weber [7], sisa dari kilang kertas mengandungi bahan inorganik berkepekatan tinggi dalam bahan koloid terampai dan mempunyai pepejal terlarut dan warna yang tinggi. Air larian permukaan sewaktu hujan biasanya mempunyai kepekatan zarahan terampai

yang tinggi [6]. Air larian permukaan mempunyai daya hakisan yang kuat dan mengakibatkan kadar hakisan tanah yang tinggi dan ini menyumbangkan kepada peningkatan pepejal terampai di kawasan tanah rata terutamanya yang terdedah akibat proses pembangunan [9].

Stesen SJ1 mempunyai purata kepekatan COD yang tertinggi (262.75 ± 5.55 mg/L) pada hari panas dan pada hari hujan (155.63 ± 138.80 mg/L). Stesen SJ1 terletak di kawasan perindustrian bercampur dan lokasinya adalah berhampiran dengan kilang pembuatan logam dan besi. Menurut Nemerow (1971), sisa utama dari industri logam adalah daripada fasa pemprosesan bahan yang berasal dari proses penyulingan ammonia, bekas penyejukan dan juga dari penyulingan tulen, yang mengandungi benzena, toluena dan silena [10]. Sisa-sisa organik ini mungkin telah menyumbangkan kepada peningkatan nilai COD di stesen pensampelan tersebut. Nilai purata yang

145

Page 8: kajian kualiti air di sekitar kawasan perindustrian subang jaya dan

MAZLIN MOKHTAR et al.: KAJIAN KUALITI AIR DI SEKITAR KAWASAN PERINDUSTRIAN

Jadual 6: Kepekatan parameter kualiti air pada hari hujan dan hari kering bagi semua stesen pensampelan kajian ini berbanding dengan EKP 1978 dan INWQS

Parameter Unit Cuaca Stesen EKP

S 1 S2 S3 S4 S5 S6 S7 S8 S9 S10 *INWQS

1. Suhu oC HH 25.90 26.20 26.40 28.20 28.10 30.10 30.30 29.60 28.60 28.40 40 HK 26.00 26.40 27.50 29.90 29.90 31.20 32.50 32.20 31.80 31.70 * Biasa % -0.19 -0.38 -2.04 -2.93 -3.10 -1.79 -3.50 -4.21 -5.30 -5.49 2. pH - HH 6.82 7.28 6.83 7.11 7.10 7.20 7.02 7.09 7.01 6.99 6.0 - 9.0 HK 6.42 7.06 6.59 7.20 7.24 7.19 6.98 7.09 6.97 6.93 6.0 - 9.0 % 3.02 1.53 1.79 -0.63 -0.98 0.07 0.29 0.00 0.29 0.43 3. DO mg/l HH 0.57 2.71 1.74 1.42 1.35 1.68 1.34 0.63 1.35 1.05 - HK 0.02 0.6 1.88 0.46 0.44 0.05 0.15 0.62 0.28 0.25 * 5 - 7 % 93.22 63.75 -3.87 51.06 50.84 94.22 79.87 0.80 65.64 61.54 4. Kekonduksian µS/cm HH 203.4 299.2 270.7 234.4 234.0 448.1 431.9 452.1 222.4 224.1 - HK 378.4 387.1 363.8 345.0 348.4 491.3 499.6 504.8 418.1 448.4 * 1000 % -30.08 -12.80 -14.67 -19.63 -20.06 -4.60 -7.27 -5.51 -30.55 -33.36 5. Turbiditi FTU HH 17.25 8.51 8.25 42.00 39.08 19.00 11.92 16.67 36.42 36.83 - HK 37.67 51.50 12.30 39.50 37.17 27.34 24.00 25.17 55.84 59.00 *50 (NTU) % -37.18 -71.64 -19.71 3.07 2.51 -18.00 -33.63 -20.32 -21.05 -23.14 6. Warna sebenar PtCo HH 98.67 45.99 48.00 213.25 210.42 99.34 62.83 95.17 195.42 194.75 - HK 181.33 241.17 65.84 204.67 203.84 144.17 131.5 139.5 272.5 295.0 * 150 (TUC)

% -29.52 -67.97 -15.67 2.05 1.59 -18.41 -35.34 -18.89 50.00 -20.47 7. TSS mg/l HH 16.15 13.00 10.83 57.03 58.00 36.18 29.35 29.10 45.70 49.35 - HK 42.65 28.65 20.15 42.65 39.85 45.85 41.35 38 60.85 59.5 * 50 % -45.07 -37.58 -30.08 14.43 18.55 -11.79 -16.97 -13.26 -14.22 -9.33 8. BOD mg/l HH 14.98 6.43 6.55 6.93 6.28 11.03 12.38 12.43 7.90 7.60 20 HK 23.60 11.15 10.60 14.60 14.90 21.55 20.20 12.85 9.65 9.85 * 3 % -22.34 -26.85 -23.62 -35.63 -40.70 -32.29 -24.00 -1.67 -9.97 -12.89 9. COD mg/l HH 155.63 46.42 34.01 25.87 18.23 91.44 87.31 57.97 40.43 11.95 50 HK 262.75 35.29 7.84 13.73 192.16 149.02 50.98 70.59 27.46 9.8 * 25 % -25.60 13.62 62.53 30.66 -82.67 -23.95 26.27 -9.82 19.10 9.89 10. AN mg/l HH 2.78 3.69 7.46 8.75 5.73 5.33 3.73 3.19 1.81 4.02 - HK 13.27 13.4 10.52 7.13 6.72 9.52 6.95 7.44 4.50 5.00 * 30 % -65.36 -56.82 -17.02 10.20 -7.95 -28.22 -30.15 -39.99 -42.63 -10.87 11. Fosfat mg/l HH 0.48 2.05 2.01 1.34 2.16 4.12 2.34 1.99 1.74 1.20 - HK 4.08 1.02 2.38 1.87 5.5 2.66 4.41 4.18 2.29 2.71 - % -78.95 33.55 -8.43 -16.51 -43.60 21.53 -30.68 -35.49 -13.65 -38.62 12. O & G mg/l HH 10.00 6.45 3.80 5.80 11.40 4.30 5.70 5.40 11.00 5.50 Tidak dapat

kesan HK 68.00 92.20 82.80 71.40 55.20 64.20 57.40 55.20 56.20 61.00 * 0.04 % -74.36 -86.92 -91.22 -84.97 -65.77 -87.45 -81.93 -82.18 -67.26 -83.46 13. Kadmium µg/l HH 0.65 0.11 0.16 0.14 0.04 0.11 0.04 0.27 0.01 0.10 10 ug/l HK 0.03 0.00 0.28 0.40 0.23 0.00 0.08 0.08 0.08 0.11 5 ug/l

% 91.18 100.0 -27.27 -48.15 -70.37 100.0 -33.33 54.29 -77.78 -4.76 14. Plumbum µg/l HH 1.38 1.00 1.38 1.25 1.13 5.00 2.00 4.50 3.00 1.13 10 u/l HK 0.50 0.25 0.25 1.50 2.00 2.25 0.75 0.75 3.25 1.25 5 ug/l

% 46.81 60.00 69.33 -9.09 -27.80 37.93 45.60 71.30 -4.00 -5.04 EKP: Peraturan Efluen Kumbahan dan Perindustrian 1978, Akta Kualiti Alam Sekeliling 1974 INWQS: Piawai Interim Kualiti Air Kebangsaan

146

Page 9: kajian kualiti air di sekitar kawasan perindustrian subang jaya dan

MAZLIN MOKHTAR et al.: KAJIAN KUALITI AIR DI SEKITAR KAWASAN PERINDUSTRIAN

dicerap menunjukkan kebanyakan stesen pensampelan mempunyai nilai COD yang tinggi secara relatif seperti di Stesen SJ1, SJ2, SJ5, SA1, SA2, SA3 dan SA4 pada hari hujan, di mana nilai COD masing-masing telah melampaui nilai maksimum 25 mg/l yang disarankan dalam INWQS Kelas IIA dan IIB.

Purata kepekatan fosfat yang diukur pada hari hujan adalah 3.11 ± 1.37 mg/L dan purata kepekatan pada hari panas adalah 1.94 ± 0.95 mg/L iaitu tidak berbeza secara bererti (p>0.10). Menurut Whipple [6], peningkatan kepekatan fosforus boleh berlaku setelah berlakunya hujan dan berpunca dari aktiviti antropogenik dan semulajadi. Aktiviti pertanian, perindustrian dan urbanisasi menyumbangkan kepada aktiviti antropogenik manakala aktiviti semulajadi seperti luluhawa batuan berfosfat dan proses pereputan bahan organik juga meningkatkan paras fosfat dalam sampel sekitaran. Kandungan fosfat bagi Stesen SJ1 (4.08 ± 3.67 mg/L), Stesen SJ5 (5.50 ± 5.71 mg/L), Stesen SA2 (4.41 ± 3.91 mg/L) dan Stesen SA3 (4.18 ± 4.13 mg/L) mencatatkan nilai yang tinggi secara relatif berbanding stesen pensampelan lain pada hari panas. Bahan-bahan berfosfat dalam baja yang digunakan untuk tumbuhan taman perumahan serta sabun detergen dijangka telah menyumbangkan kepada kandungan fosfat yang tinggi dalam sistem air. Menurut Hem [11], fosforus merupakan konstituen signifikan dalam kumbahan kerana ia adalah unsur yang penting dalam metabolisme dan biasanya wujud dalam sisa metabolisme haiwan dan manusia.

Purata kepekatan nitrat di Stesen SJ1 (8.03 mg/L), Stesen SJ2 (7.42 mg/L) dan Stesen SJ3 (8.58 mg/L) di Subang Jaya, serta Stesen SA1 (7.43 mg/L), Stesen SA2 (11.97 mg/L) dan Stesen SA3 (8.02 mg/L) di Shah Alam menunjukkan nilai N-NH3 (ammonia) yang tinggi secara relatif berbanding stesen pensampelan yang lain. Keadaan ini mungkin kerana stesen pensampelan tersebut adalah berdekatan dengan kawasan perindustrian. Ammonia merupakan komponen nitrogen yang paling banyak dihasilkan dalam sisa pembuangan bandar. Kehadiran kuantiti ammonia yang banyak dalam air memaparkan tahap pencemaran kumbahan yang tinggi. Komponen organik nitrogen boleh berasal daripada sisa buangan tumbuhan dan haiwan, termasuk sisa dari haiwan tersebut, sisa dari industri pembuatan makanan, farmaseutikal, plastik dan tekstil [12].

Stesen SJ1 merupakan stesen yang mencerapkan nilai purata BOD yang tertinggi pada hari panas (23.60 ± 1.84 mg/L) dan pada hari hujan (14.98 ± 1.78 mg/L). SJ1 terletak berhampiran dengan kilang pembuatan logam besi. Di sekeliling stesen ini merupakan satu kawasan perindustrian bercampur iaitu terdapat industri plastik, kedai pembasuh,

bengkel otomobil, industri pembuatan mesin, Pasaraya Giant dan lain-lain industri ringan. Kawasan industri biasanya mengandungi efluen berorganik tinggi yang boleh meningkatan paras kepekatan BOD dalam sistem air.

Stesen SJ1 (Cd 0.34 mg/L) merupakan stesen yang terletak dalam kawasan perindustrian bercampur dan mencatatkan nilai paras kepekatan logam kadmium yang relatif tinggi. Menurut Spliethoff dan Hemond [13], logam kadmium merupakan bahan asas bagi industri bercampur seperti pembuatan bahan kimia. Ujian ANOVA faktor tunggal menunjukkan tiada perbezaan yang signifikan (p>0.10) bagi kepekatan Cd antara stesen dan juga antara hari panas dan hari hujan.

Kepekatan purata plumbum yang dicerap pada hari hujan sepanjang kajian menunjukkan nilai yang relatif lebih tinggi (0.16 ± 0.19 mg/L) berbanding pada hari panas ( 0.13 ± 0.13 mg/L). Menurut Camp dan Meserve [14], berdasarkan pencemaran yang diakibatkan daripada kawasan bandar, terdapat peningkatan masalah kontaminasi logam berat semasa berlakunya air larian permukaan di kawasan bandar. Mendakan atmosfera boleh mengandungi kepekatan logam berat yang tinggi sepertimana kajian yang dilakukan ke atas Sungai Niagara di Amerika Syarikat [14]. Sejak bermulanya era perindustrian, terdapat peningkatan penggunaan logam plumbum dalam sekitaran seperti penggunaan plumbum dalam minyak kenderaan berenjin. Menurut Spliethoff dan Hemond [13], kewujudan plumbum bukan sahaja di kawasan kepadatan kenderaan, tetapi juga dalam atmosfera yang turun dengan air hujan dan diangkut ke sedimen akuatik dengan berkesan berbanding dari permukaan kawasan pertanian. Perbandingan dengan INWQS pada Hari Panas Paras kepekatan DO pada setiap stesen secara relatifnya memaparkan nilai purata yang rendah iaitu berada dalam julat 0.02-0.62 mg/L dan semua stesen yang dikaji adalah digolongkan dalam sub-kelas V berdasarkan DO sahaja. Stesen SJ3 merupakan stesen yang dikelaskan dalam DO sub-kelas IV dengan nilai kepekatan 1.88 mg/L. Stesen SJ2, SJ3, SA4 dan SA5 digolongkan dalam DO sub-kelas III, manakala Stesen SJ4, SJ5 dan SA3 berada dalam DO sub-kelas IV. Stesen SJ1, SA1 dan SA2 digolongkan dalam DO sub-kelas V. Stesen SJ1, SA1 dan SA2 merupakan stesen yang terletak di kawasan perindustrian yang menerima luahan sisa buangan industri yang mengandungi bahan pencemar yang menyumbangkan nilai BOD tinggi.

Nilai COD yang dicerap adalah tidak sekata dan mempunyai nilai julat purata yang tinggi iaitu dari 7.84 - 262.75 mg/L. Stesen SJ1 mencerapkan

147

Page 10: kajian kualiti air di sekitar kawasan perindustrian subang jaya dan

MAZLIN MOKHTAR et al.: KAJIAN KUALITI AIR DI SEKITAR KAWASAN PERINDUSTRIAN

nilai yang tertinggi dan berada dalam COD sub-kelas V. Julat nilai kepekatan TSS berada dalam lingkungan 20.15-60.85 mg/L dan didapati bahawa semua stesen pensampelan adalah digolongkan dalam TSS sub-kelas II kecuali Stesen SJ3 (20.15 mg/L) di dalam TSS sub-kelas I. Nilai kepekatan yang dicerap bagi nitrogen ammonia adalah tinggi dan melebih 4.00 mg/L dan semua stesen adalah dimasukkan dalam ammonia sub-kelas V. Secara umumnya, paras kepekatan nitrogen ammonia yang tinggi adalah disebabkan oleh air buangan kumbahan di sekitar kawasan perindustrian. Secara keseluruhan nilai pH yang dicerap berada dalam pH sub-kelas I dan II. Perbandingan dengan INWQS pada Hari Hujan Kepekatan DO yang diukur pada hari hujan berada dalam julat 0.57 - 2.71 mg/L. Peningkatan DO adalah disebabkan oleh peningkatan kelajuan aliran air secara relatif sewaktu hari hujan yang meningkatkan kelarutan oksigen dalam air. Stesen SJ1 dan SA3 masing-masing dengan nilai 0.57 mg/L dan 0.63 mg/L terangkum dalam DO sub-kelas V yang dianggapkan tercemar manakala stesen lain tergolong dalam DO sub-kelas IV.

Peningkatan sub-kelas bagi BOD diperhatikan pada hari hujan. Stesen SJ1 (dari sub-kelas V ke IV), SJ4 (dari sub-kelas IV ke III), SJ5 (dari sub-kelas IV ke III), SA1 (dari sub-kelas V ke III) dan SA2 (dari sub-kelas V ke III). Julat nilai kepekatan BOD pada hari hujan adalah dalam lingkungan 6.28 - 14.98 mg/L.

Cerapan nilai kepekatan COD adalah secara relatifnya tidak sekata. Stesen SJ5, SA4 dan SA5 berada dalam COD Kelas II dan mencapai kelas yang lebih baik pada hari hujan berbanding pada hari panas. Walau bagaimanapun, penurunan kelas berlaku di Stesen SJ4 (dari COD Kelas II ke III) dan SJ5 (dari Kelas II ke III) juga pada hari hujan. Penurunan kualiti air adalah berpunca daripada hakisan tanah di tepi Sungai Klang yang dikaji kerana projek pembinaan konkrit sungai sedang dijalankan. Nilai kepekatan nitrogen ammonia adalah dalam julat 2.78 - 8.75 mg/L dan digolongkan dalam sub-kelas V, tetapi Stesen SA4 telah mencapai kelas yang lebih baik iaitu sub-kelas IV dengan nilai kepekatan 1.81 mg/L. Kebanyakan nilai ammonia yang diukur berada dalam julat 7.01 - 7.28 mg/l iaitu dalam sub-kelas II. Perbandingan hasil kajian ini dengan Akta Kualiti Alam Sekeliling, 1974 (Peraturan Efluen Kumbahan dan Perindustrian 1978) Perbandingan hasil kajian ini dengan Piawai B Peraturan Efluen Kumbahan dan Perindustrian (EKP) 1978 menunjukkan bahawa purata suhu keseluruhan yang dicerap (29.05ºC) bagi semua stesen pensampelan, purata pada hari panas (29.9 ± 2.4ºC)

dan hari hujan (28.2 ± 1.6ºC) masih berada di bawah had 40.0oC. Nilai tertinggi yang didapati adalah 32.5oC di Stesen SA2 pada hari panas. Julat nilai purata pada hari panas adalah 26.0-32.5oC manakala pada hari hujan adalah 25.9-30.3oC. Parameter pH di semua stesen juga mematuhi Piawai B EKP 1978 yang disarankan iaitu pH 5.5-9.0.

Had maksimum yang disarankan oleh Piawai B EKP 1978 bagi BOD (50 mg/L), TSS (100 mg/L), logam plumbum (0.50 mg/L) dan kadmium (0.02 mg/L) secara umumnya tidak dilampaui oleh keputusan kajian ini di semua stesen pensampelan sama ada pada hari panas atau hari hujan. Beberapa pengecualian adalah Stesen SJ1 yang mempunyai nilai COD purata 262.75 mg/L pada hari panas dan 155.63 mg/L pada hari hujan. Stesen SA1 dan SA2 juga mempunyai nilai COD yang melebihi Piawai B pada hari panas masing-masing dengan nilai 192.16 mg/l dan 149.02 mg/L. Tiada satu stesen yang mematuhi Piawai B bagi minyak dan gris semasa hari panas iaitu semua stesen melewati had 10 mg/L. Walau bagaimanapun, pada hari hujan keadaan ini berubah dan didapati Stesen SJ2, SJ3, SJ4, SA2, SA3, SA4 dan SA5 mempunyai nilai minyak & gris di bawah 10 mg/L.

Kesimpulan

Kajian kualiti air di Kawasan Perindustrian Subang Jaya dan Shah Alam ini menunjukkan bahawa Stesen SJ1 dan Stesen SA1 merupakan stesen pensampelan yang paling tercemar berdasarkan parameter kajian yang telah diukur. Stesen SJ1 dan Stesen SA1 masing-masing mempunyai nilai Indeks Kualiti Air (IKA) 27.32% dan 30.15% iaitu digolongkan dalam Kelas V (tercemar) pada hari panas. Kedua-dua stesen ini mengandungi paras kepekatan BOD, COD, warna dan ammonia yang relatif tinggi. Nilai purata DO di SJ1 & SA1 adalah relatif rendah pada hari panas iaitu 0.47 ± 0.54 mg/L. Ini adalah sejajar dengan laporan umum yang dikeluarkan oleh Jabatan Alam Sekitar Malaysia [15, 16, 17] yang mengelaskan Sg Klang sebagai satu daripada sungai yang tercemar di Malaysia berdasarkan enam parameter IKA pada tahun 1992, 1994 dan 1996.

Ujian ANOVA faktor tunggal menunjukkan terdapat perbezaan yang signifikan (p<0.05) bagi nilai suhu, DO, warna, kekeruhan, fosfat dan kekonduksian antara hari panas dengan hari hujan.

Stesen SJ4 dan Stesen SJ5 di Subang Jaya yang terletak di Sungai Klang mempunyai nilai purata TSS, warna dan kekeruhan yang relatif tinggi. Ini mungkin disebabkan oleh kerja pembinaan konkrit yang sedang dijalankan di tebing Sungai Klang sewaktu kajian ini sedang dijalankan. Hakisan tanah dan sedimentasi yang berlaku ketika hujan didapati telah

148

Page 11: kajian kualiti air di sekitar kawasan perindustrian subang jaya dan

MAZLIN MOKHTAR et al.: KAJIAN KUALITI AIR DI SEKITAR KAWASAN PERINDUSTRIAN

meningkatkan paras kepekatan TSS, warna dan kekeruhan. Penentuan IKA menunjukkan bahawa kebanyakan stesen terletak dalam dalam Kelas IV (sederhana tercemar) iaitu dengan julat IKA 32.39 - 48.37% pada hari panas. Terdapat peningkatan dalam IKA pada hari hujan disebabkan pencairan. Hasil kajian ini telah dibandingkan dengan nilai-nilai INWQS dan Akta Kualiti Alam Sekeliling 1974 (Peraturan Efluen Kumbahan dan Perindustrian, EKP 1978). Kepekatan plumbum dan kadmium di stesen-stesn kajian ini masih mematuhi had maksimum yang ditetapkan oleh Piawai B (EKP 1978). Parameter suhu dan pH tergolong dalam sub-kelas II berdasarkan INWQS. Nilai kepekatan fosfat dan N-NH3 di kawasan perindustrian didapati relatif tinggi berbanding sub-kelas II INWQS.

Kajian yang telah dilakukan di Kawasan Perindustrian Subang Jaya dan Shah Alam ini secara keseluruhannya menunjukkan tahap pencemaran sederhana berdasarkan IKA. Hasil kajian ini telah membekalkan data bagi rujukan masa depan khususnya yang melibatkan titik-titik pensampelan yang hampir dengan kawasan perindustrian di Subang Jaya dan Shah Alam. Data sejarah yang terlapor sebelum ini biasanya melibatkan hasil pemonitoran di stesen pensampelan di tebing-tebing sungai sahaja dan tidak ada di parit-parit tertentu. Data kajian ini mungkin boleh memberikan input dalam menganggarkan luahan bahan pencemar tertentu oleh aktiviti industri. Hasil kajian ini mendapati kebanyakan industri masih tidak mencapai status pematuhan yang memuaskan untuk sesetengah parameter kajian. Program pemantauan kualiti air perlu dijalankan secara berterusan dalam jangka masa yang lebih panjang untuk menilai status kualiti air dan tahap pencemaran sistem saliran air di kawasan-kawasan tersebut.

Rujukan 1. Jabatan Alam Sekitar. 1984. Masalah pencemaran

kelodakan Sungai Klang. Malaysia: Kementerian Sains, Teknologi dan Alam Sekitar.

2 APHA. 1995. Standard methods for the examination of water and wastewater. Ed. ke 19. Washington:

American Public Health Association, AWWA, MPCE.

3. Othman, T. 1986. Kajian kualiti Teluk Sepanggar dan muara Sungai Inaman. Tesis Sm. Sn. (Kep). Jabatan Geografi, Fakulti Sains Kemasyarakatan dan Kemanusiaan, Universiti Kebangsaan Malaysia.

4. Chapman, D. 1992. Water quality assessment: a guide to use of biota, sediments and water in the environment monitoring. London: Chapman & Hall.

5. Nathanson, J.A. 1986. Basic environmental technology: water supply, waste disposal and pollution control. United States of America: John Wiley & Sons, Inc.

6. Whipple, Jr. W. 1977. Planning of water quality systems. United States of America: D. C. Health and Company.

7. Mancy, K.H. & Weber Jr, W.J. 1971. Analysis of industrial wastewater. United States of America: John Wiley & Sons.

8. McCaull, J. & Crossland, J. 1974. Water pollution. San Francisco: Harcourt Brace Jovanovich, Inc.

9. Gower, A.M. 1980. Ecological effects of changes in water quality. Dlm. Gower, A.M. (Ed.). Water quality in catchment ecosystems, hlm. 145 172. New York: John Wiley & Sons.

10. Nemerow, N.L. 1971. Liquid waste of industry. California: Wesley Publishing Company.

11. Hem, J.D. 1970. Study and interpretation of the chemical characteristics of natural waters. Ed. ke 2. Washington: United States Government Printing Office.

12. Allen, H.E. & Mancy, K.H. 1972. Design of measurement systems for water analysis. Dlm. Ciaccio, L.L. (Ed.). Water and water pollution handbook 3, hlm. 971 1017. New York: Marrel Dekker, Inc.

13. Spliethoff, H.M. & Hemond, H.F. 1996. History of toxic discharge to surface waters of the Aberjona Watershed. Journal of Environmental Science & Technology 30(1): 121 127.

14. Camp, T.R. & Meserve, R.L. 1974. Water and its impurities. Ed. ke 2. Stroudsburd: Dowden, Hutchinson & Ross, Inc.

15. DOE (Department of Environment, MOSTE, Malaysia) 1992. Malaysia Environmental Quality Report 1992. DOE, Kuala Lumpur. Pp. 13-14.

16. DOE (Department of Environment, MOSTE, Malaysia) 1994. Malaysia Environmental Quality Report 1994. DOE, Kuala Lumpur. Pp. 18 – 19.

17. DOE (Department of Environment, MOSTE, Malaysia) 1996. Malaysia Environmental Quality Report 1996. DOE, Kuala Lumpur. Pp. 15 – 21.

149