SISTEM KALIBRASI TERMOMETER INFRARED UNTUK RENTANG 50 OC – 500 OC

INFRARED THERMOMETER CALIBRATION SYSTEM FOR RANGES 50 OC – 500 OC

Hidayat WiriadinataPuslit KIM-LIPI, Kompleks Puspiptek Serpong, Tangerang 15314, hidayatwr@kim.lipi.go.id

INTISARIBanyak proses produksi memerlukan pengukuran suhu. Pada kondisi-kondisi tertentu pengukuran suhu secara kontak (menggunakan termokopel atau termometer gelas) tidak mungkin dilakukan, misalnya untuk benda-ukur yang bergerak, bersuhu tinggi atau sulit dijangkau. Pada situasi seperti itu, maka pengukuran suhu harus dilakukan secara non kontak dengan menggunakan termometer radiasi atau termometer infrared. Akhir-akhir ini penggunaan termometer radiasi, khususnya untuk rentang suhu di bawah 600OC, semakin meningkat sehingga untuk mengantisipasi adanya permintaan jasa kalibrasi pada rentang tersebut, Laboratorium Metrologi Suhu Puslit KIM LIPI telah membangun sistem kalibrasi termometer infrared untuk rentang 50 OC – 500 OC. Sistem tersusun dari benda-hitam variabel sebagai media kalibrasi dan termometer tahanan platina (Pt-100) sebagai termometer standar. Estimasi kemampuan ukur terbaik (KUT) sistem pada tingkat kepercayaan 95% dan faktor cakupan k = 2 untuk suhu 50OC dan 500OC masing-masing adalah ± 0,30 OC dan ± 2,90 OC

ABSTRACTMuch of production processes need temperature measurements. In certain conditions, for example when measurand is in motion, has high temperature or difficult to reach, temperature measurement by using contact thermometer ( like thermocouple or liquid in glass thermometer ) is impossible. In this situation, temperature must be measured noncontactly by using a radiation thermometer or infrared thermometer. Recently, application of infred thermometer, especially in temperature range below 600OC has been increasing. As anticipation for calibration request in this temperature range, Temperature Metrology Laboratory of Puslit KIM LIPI has built a calibration system for infrared thermometer in range 50 OC – 500 OC. The system is composed of variable blackbody as a calibration medium and platinum resistance thermometer (Pt-100) as standard thermometer. The best measurement capability (BMC) of the system at confidence level 95% and coverage factor k = 2.0 for 50OC and 500OC are estimated : ± 0,30 OC and ± 2,90 OC.

Kata Kunci : sistem kalibrasi, termometer infrared, benda-hitam variabel, termometer tahanan platina (Pt-100), kemampuan ukur terbaik (KUT)Keywords : calibration system ,infrared thermometer, variable blackbody, platinum resistance thermometer (Pt-100), best-measurement capability (BMC).

top related